메뉴 건너뛰기




Volumn 33, Issue 2, 1998, Pages 166-178

Flow cytometric quantitation of immunofluorescence intensity: Problems and perspectives

(26)  Gratama, Jan W a   D'Hautcourt, Jean Luc b   Mandy, Frank c   Rothe, Gregor d   Barnett, David e   Janossy, George f   Papa, Stefano g   Schmitz, Gerd d   Lenkei, Rodica h   Schmitz, G i   Autran, B i   Brando, B i   D'Hautcourt, J L i   Gratama, J W i   Huber, A i   Janossy, G i   Johnsen, H E i   Kappelmayer, J i   Lenkei, R i   Orfao, A i   more..


Author keywords

Calibration; Flow cytometry; Immunofluorescence; Instrument setup; Quantitation

Indexed keywords

CD38 ANTIGEN; CD4 ANTIGEN; CD8 ANTIGEN; FLUOROCHROME; OKT 4; PADGEM PROTEIN; PHYCOERYTHRIN; REAGENT;

EID: 0032189327     PISSN: 01964763     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-0320(19981001)33:2<166::AID-CYTO11>3.0.CO;2-S     Document Type: Article
Times cited : (142)

References (43)
  • 2
    • 0029797856 scopus 로고    scopus 로고
    • Evaluation of a novel stable whole blood quality control material for lymphocyte subset analysis: Results from the UK NEQAS Immune Monitoring Scheme
    • Barnett D, Granger V, Mayr P, Storie I, Wilson GA, Reilly JT: Evaluation of a novel stable whole blood quality control material for lymphocyte subset analysis: Results from the UK NEQAS Immune Monitoring Scheme. Cytometry 26:216-222, 1996.
    • (1996) Cytometry , vol.26 , pp. 216-222
    • Barnett, D.1    Granger, V.2    Mayr, P.3    Storie, I.4    Wilson, G.A.5    Reilly, J.T.6
  • 3
    • 0031809649 scopus 로고    scopus 로고
    • Determination of leukocyte antibody binding capacity (ABC): The need for standardization
    • Barnett D, Storie I, Wilson GA, Granger V, Reilly JT: Determination of leukocyte antibody binding capacity (ABC): The need for standardization. Clin Lab Haematol 20:155-164, 1998.
    • (1998) Clin Lab Haematol , vol.20 , pp. 155-164
    • Barnett, D.1    Storie, I.2    Wilson, G.A.3    Granger, V.4    Reilly, J.T.5
  • 4
    • 0021984194 scopus 로고
    • Flow cytometric analysis of fluorescein-conjugated estradiol (E-BSA-FITC) binding in breast cancer suspensions
    • Benz C, Witznitzer I, Lee SH: Flow cytometric analysis of fluorescein-conjugated estradiol (E-BSA-FITC) binding in breast cancer suspensions. Cytometry 6:260-267, 1986.
    • (1986) Cytometry , vol.6 , pp. 260-267
    • Benz, C.1    Witznitzer, I.2    Lee, S.H.3
  • 5
    • 0029902746 scopus 로고    scopus 로고
    • Quantitative analysis of leukocyte membrane antigen expression: Normal adult values
    • Bikoue A, George F, Poncelet P, Mutin M, Janossy G, Sampol J: Quantitative analysis of leukocyte membrane antigen expression: Normal adult values. Cytometry 26:137-147, 1996.
    • (1996) Cytometry , vol.26 , pp. 137-147
    • Bikoue, A.1    George, F.2    Poncelet, P.3    Mutin, M.4    Janossy, G.5    Sampol, J.6
  • 6
    • 0030786596 scopus 로고    scopus 로고
    • Quantitative analysis of leukocyte membrane antigen expression on human fetal and cord blood: Normal values and changes during development
    • Bikoue A, George F, Poncelet P, Mutin M, Janossy G, Sampol J: Quantitative analysis of leukocyte membrane antigen expression on human fetal and cord blood: Normal values and changes during development. Clin Immunol Immunopathol 84:56-64, 1997.
    • (1997) Clin Immunol Immunopathol , vol.84 , pp. 56-64
    • Bikoue, A.1    George, F.2    Poncelet, P.3    Mutin, M.4    Janossy, G.5    Sampol, J.6
  • 7
    • 0030828712 scopus 로고    scopus 로고
    • U.S.-Canadian consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: Data analysis and interpretation
    • Borowitz MJ, Bray R, Gascoyne R, Melnick S, Parker JW, Picker L, Stetler-Stevenson M: U.S.-Canadian consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: Data analysis and interpretation. Cytometry 30:236-244, 1997.
    • (1997) Cytometry , vol.30 , pp. 236-244
    • Borowitz, M.J.1    Bray, R.2    Gascoyne, R.3    Melnick, S.4    Parker, J.W.5    Picker, L.6    Stetler-Stevenson, M.7
  • 9
    • 0030450575 scopus 로고    scopus 로고
    • Quantitative determination of surface antibody binding capacities of immune subsets present in peripheral blood of healthy adult donors
    • Denny TN, Stein D, Mui T, Scolpino A, Holland B: Quantitative determination of surface antibody binding capacities of immune subsets present in peripheral blood of healthy adult donors. Cytometry 26:265-274, 1996.
    • (1996) Cytometry , vol.26 , pp. 265-274
    • Denny, T.N.1    Stein, D.2    Mui, T.3    Scolpino, A.4    Holland, B.5
  • 10
    • 0025273023 scopus 로고
    • Logarithmic amplifiers
    • Gandler W, Shapiro H: Logarithmic amplifiers. Cytometry 11:447-450, 1990.
    • (1990) Cytometry , vol.11 , pp. 447-450
    • Gandler, W.1    Shapiro, H.2
  • 11
    • 0030916138 scopus 로고    scopus 로고
    • Reduction of interlaboratory variability in flow cytometric immunophenotyping by standardization of instrument set-up and calibration, and standard list mode data analysis
    • Gratama JW, Kraan J, Adriaansen H, Hooibrink B, Levering W, Reinders P, Van den Beemd MWM, Van der Holt B, Bolhuis RLH: Reduction of interlaboratory variability in flow cytometric immunophenotyping by standardization of instrument set-up and calibration, and standard list mode data analysis. Cytometry 30: 10-22, 1997.
    • (1997) Cytometry , vol.30 , pp. 10-22
    • Gratama, J.W.1    Kraan, J.2    Adriaansen, H.3    Hooibrink, B.4    Levering, W.5    Reinders, P.6    Van Den Beemd, M.W.M.7    Van Der Holt, B.8    Bolhuis, R.L.H.9
  • 12
    • 85008429876 scopus 로고    scopus 로고
    • Standardization, calibration, and control in flow cytometry
    • Robinson JP, Darzynkiewicz Z, Dean PN, Orfao A, Rabinovitch PS, Stewart CC, Tanke HJ, Wheeless LL (eds). Wiley-Liss, New York
    • Hoffman RA: Standardization, calibration, and control in flow cytometry. In: Current Protocols in Cytometry, Robinson JP, Darzynkiewicz Z, Dean PN, Orfao A, Rabinovitch PS, Stewart CC, Tanke HJ, Wheeless LL (eds). Wiley-Liss, New York, 1997, pp 1.3.1-1.3.19.
    • (1997) Current Protocols in Cytometry , pp. 131-1319
    • Hoffman, R.A.1
  • 13
    • 85069068018 scopus 로고    scopus 로고
    • Protocol for general distribution developed with support from U.S. Public Health Service Award U01-A1-37613
    • + T lymphocytes of HIV-infected individuals. Protocol for general distribution developed with support from U.S. Public Health Service Award U01-A1-37613. Available at: http:// cyto.mednet.ucla.edu/.
    • + T Lymphocytes of HIV-infected Individuals
    • Hultin, L.E.1    Giorgi, J.V.2
  • 14
    • 0032190567 scopus 로고    scopus 로고
    • Quantitation of CD38 activation antigen expression on CD8+ T cells in HIV-1 infection
    • Hultin LE, Matud JL, Giorgi JV: Quantitation of CD38 activation antigen expression on CD8+ T cells in HIV-1 infection. Cytometry 33:123-132, 1998.
    • (1998) Cytometry , vol.33 , pp. 123-132
    • Hultin, L.E.1    Matud, J.L.2    Giorgi, J.V.3
  • 15
    • 0029009812 scopus 로고
    • Peripheral blood cell preparation influences the level of expression of leukocyte cell surface markers as assessed with quantitative multicolor flow cytometry
    • Islam D, Lindberg AA, Christensson B: Peripheral blood cell preparation influences the level of expression of leukocyte cell surface markers as assessed with quantitative multicolor flow cytometry. Cytometry 22:128-134, 1995.
    • (1995) Cytometry , vol.22 , pp. 128-134
    • Islam, D.1    Lindberg, A.A.2    Christensson, B.3
  • 20
    • 0028141878 scopus 로고
    • Leukemia-associated changes identified by quantitative flow cytometry. II. CD5 overexpression and monitoring in B-CLL
    • Lavabre-Bertrand T, Janossy G, Exbayat C, Bourguard P, Duperray C, Navarro M: Leukemia-associated changes identified by quantitative flow cytometry. II. CD5 overexpression and monitoring in B-CLL. Leukemia 8:1557-1563, 1994.
    • (1994) Leukemia , vol.8 , pp. 1557-1563
    • Lavabre-Bertrand, T.1    Janossy, G.2    Exbayat, C.3    Bourguard, P.4    Duperray, C.5    Navarro, M.6
  • 21
    • 0029005434 scopus 로고
    • Determination of the antibody binding capacity of lymphocyte membrane antigens by flow cytometry in 58 blood donors
    • Lenkei R, Andersson B: Determination of the antibody binding capacity of lymphocyte membrane antigens by flow cytometry in 58 blood donors. J Immunol Methods 183:267-277, 1995.
    • (1995) J Immunol Methods , vol.183 , pp. 267-277
    • Lenkei, R.1    Andersson, B.2
  • 23
    • 76549221753 scopus 로고
    • The use of control charts in the clinical laboratory
    • Levey S, Jennings ER: The use of control charts in the clinical laboratory. Am J Clin Pathol 20:1059-1066, 1950.
    • (1950) Am J Clin Pathol , vol.20 , pp. 1059-1066
    • Levey, S.1    Jennings, E.R.2
  • 27
    • 0020685156 scopus 로고
    • Determination of linear fluorescence intensities from flow cytometric data accumulated with logarithmic amplifiers
    • Muirhead KA, Schmitt TC, Muirhead AR: Determination of linear fluorescence intensities from flow cytometric data accumulated with logarithmic amplifiers. Cytometry 3:251-256, 1983.
    • (1983) Cytometry , vol.3 , pp. 251-256
    • Muirhead, K.A.1    Schmitt, T.C.2    Muirhead, A.R.3
  • 28
    • 0022399329 scopus 로고
    • Cytofluorometric quantification of cell surface antigens by indirect immunofluorescence using monoclonal antibodies
    • Poncelet P, Carayon P: Cytofluorometric quantification of cell surface antigens by indirect immunofluorescence using monoclonal antibodies. J Immunol Methods 85:65-74, 1985.
    • (1985) J Immunol Methods , vol.85 , pp. 65-74
    • Poncelet, P.1    Carayon, P.2
  • 31
    • 0023791873 scopus 로고
    • Conversion of logarithmic channel numbers into relative linear fluorescence intensity
    • Schmid I, Schmid P, Giorgi JV: Conversion of logarithmic channel numbers into relative linear fluorescence intensity. Cytometry 9:533-538, 1988.
    • (1988) Cytometry , vol.9 , pp. 533-538
    • Schmid, I.1    Schmid, P.2    Giorgi, J.V.3
  • 33
    • 0027289601 scopus 로고
    • Development of clinical standards for flow cytometry
    • Schwartz A, Fernández-Repollet E: Development of clinical standards for flow cytometry. Ann NY Acad Sci 677:28-39, 1993.
    • (1993) Ann NY Acad Sci , vol.677 , pp. 28-39
    • Schwartz, A.1    Fernández-Repollet, E.2
  • 34
    • 0029670352 scopus 로고    scopus 로고
    • Standardizing flow cytometry: Construction of a standardized fluorescence calibration plot using matching spectral calibrators
    • Schwartz A, Fernández-Repollet E, Vogt R, Gratama JW: Standardizing flow cytometry: Construction of a standardized fluorescence calibration plot using matching spectral calibrators. Cytometry 26:22-31, 1996.
    • (1996) Cytometry , vol.26 , pp. 22-31
    • Schwartz, A.1    Fernández-Repollet, E.2    Vogt, R.3    Gratama, J.W.4
  • 35
    • 0032189878 scopus 로고    scopus 로고
    • Standardizing flow cytometry: A classification system of fluorescent standards used for flow cytometry
    • Schwartz A, Marti GE, Poon R, Gratama JW, Fernandes-Repollet E: Standardizing flow cytometry: A classification system of fluorescent standards used for flow cytometry. Cytometry 33:106-114, 1998.
    • (1998) Cytometry , vol.33 , pp. 106-114
    • Schwartz, A.1    Marti, G.E.2    Poon, R.3    Gratama, J.W.4    Fernandes-Repollet, E.5
  • 36
    • 0042108342 scopus 로고
    • Falling off a log
    • Wiley-Liss, New York
    • Shapiro HM: Falling off a log. In: Practical Flow Cytometry. Wiley-Liss, New York, 1995, pp. 168-169.
    • (1995) Practical Flow Cytometry , pp. 168-169
    • Shapiro, H.M.1
  • 37
    • 85069081489 scopus 로고
    • MESF Units
    • Wiley-Liss, New York
    • Shapiro HM: MESF Units. In: Practical Flow Cytometry. Wiley-Liss, New York, 1995, pp. 173-174.
    • (1995) Practical Flow Cytometry , pp. 173-174
    • Shapiro, H.M.1
  • 38
    • 0030840151 scopus 로고    scopus 로고
    • U.S.-Canadian consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: Standardization and validation of laboratory procedures
    • Stelzer GT, Marti G, Hurley A, McCoy Jr P, Lovett EJ, Schwartz A: U.S.-Canadian consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: Standardization and validation of laboratory procedures. Cytometry 30:214-230, 1997.
    • (1997) Cytometry , vol.30 , pp. 214-230
    • Stelzer, G.T.1    Marti, G.2    Hurley, A.3    McCoy Jr., P.4    Lovett, E.J.5    Schwartz, A.6
  • 39
    • 0029796870 scopus 로고    scopus 로고
    • Binding of PE-Cy5 conjugates to the human high-affinity receptor for IgG (CD64)
    • Van Vugt MJ, Van den Herik-Oudijk IE, Van de Winkel JGJ: Binding of PE-Cy5 conjugates to the human high-affinity receptor for IgG (CD64) [letter]. Blood 88:2358-2560, 1996.
    • (1996) Blood , vol.88 , pp. 2358-2560
    • Van Vugt, M.J.1    Van Den Herik-Oudijk, I.E.2    Van De Winkel, J.G.J.3
  • 40
    • 0025914430 scopus 로고
    • Interlaboratory study of cellular fluorescence intensity measurements with fluorescein-labeled microbead standards
    • Vogt RF, Cross GD, Phillips DL, Henderson LO, Hannon WH: Interlaboratory study of cellular fluorescence intensity measurements with fluorescein-labeled microbead standards. Cytometry 12:525-536, 1991.
    • (1991) Cytometry , vol.12 , pp. 525-536
    • Vogt, R.F.1    Cross, G.D.2    Phillips, D.L.3    Henderson, L.O.4    Hannon, W.H.5
  • 41
    • 0009714345 scopus 로고
    • Quantitative calibration of FL intensity for clinical and research applications of immunophenotyping by flow cytometry
    • Tyrer HW (ed). Ablex, Norwood, NJ
    • Vogt RF, Marti GE, Schwartz A: Quantitative calibration of FL intensity for clinical and research applications of immunophenotyping by flow cytometry. In: Reviews in Biotechnology and Bioengineering, Vol. 1, Tyrer HW (ed). Ablex, Norwood, NJ, 1995, pp. 147-175.
    • (1995) Reviews in Biotechnology and Bioengineering , vol.1 , pp. 147-175
    • Vogt, R.F.1    Marti, G.E.2    Schwartz, A.3
  • 42
  • 43
    • 0020639641 scopus 로고
    • A predictive model for quality control: Effects of the prevalence of errors on the performance of control procedures
    • Westgard JO, Groth T: A predictive model for quality control: Effects of the prevalence of errors on the performance of control procedures. Am J Clin Pathol 80:49-56, 1983.
    • (1983) Am J Clin Pathol , vol.80 , pp. 49-56
    • Westgard, J.O.1    Groth, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.