메뉴 건너뛰기




Volumn 73, Issue 1, 1998, Pages 59-63

A piezoelectric immunosensor for complement C4 using protein A oriented immobilization of antibody

Author keywords

Complement C4; Oriented immobilization of antibody; Piezoelectric immunosensor; Protein A

Indexed keywords

ADHESION; ADSORPTION; ANTIBODIES; CELL IMMOBILIZATION; CELL MEMBRANES; CROSSLINKING; ELECTRODES; GOLD; PIEZOELECTRIC DEVICES;

EID: 0032170502     PISSN: 02682575     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4660(199809)73:1<59::AID-JCTB917>3.0.CO;2-3     Document Type: Article
Times cited : (24)

References (18)
  • 1
    • 0027996780 scopus 로고
    • Recent developments in piezoelectric immunosensors
    • Suleiman, A. A. & Guilbault, G. G., Recent developments in piezoelectric immunosensors. Analyst, 119 (1994) 2279-82.
    • (1994) Analyst , vol.119 , pp. 2279-2282
    • Suleiman, A.A.1    Guilbault, G.G.2
  • 2
    • 0029158262 scopus 로고
    • The quartz crystal microbalance as biosensor: A status report on its future
    • Minunni, M., Mascini, M., Guilbault, G. G. & Hock, B., The quartz crystal microbalance as biosensor: a status report on its future. Anal. Lett., 28 (1995) 749-64.
    • (1995) Anal. Lett. , vol.28 , pp. 749-764
    • Minunni, M.1    Mascini, M.2    Guilbault, G.G.3    Hock, B.4
  • 3
    • 84951279351 scopus 로고
    • The use of oscillators for weighting thin layers and for microweighting
    • Sauerbrey, G., The use of oscillators for weighting thin layers and for microweighting. Z. Phys., 155 (1959) 206-22.
    • (1959) Z. Phys. , vol.155 , pp. 206-222
    • Sauerbrey, G.1
  • 4
    • 0027162532 scopus 로고
    • Detection of human T-lymphocytes with a piezolectric immunosensor
    • Konig, B. & Gratzel, M., Detection of human T-lymphocytes with a piezolectric immunosensor. Anal. Chim. Acta, 281 (1993) 13-18.
    • (1993) Anal. Chim. Acta , vol.281 , pp. 13-18
    • Konig, B.1    Gratzel, M.2
  • 5
    • 0025404361 scopus 로고
    • Development of a piezoelectric immunosensor for the detection of Salmonella typhimurium
    • Prusak-Sochaczewski, E., Luong, J. H. T. & Guilbault, G. G., Development of a piezoelectric immunosensor for the detection of Salmonella typhimurium. Enzyme Microb. Technol., 12 (1990) 173-7.
    • (1990) Enzyme Microb. Technol. , vol.12 , pp. 173-177
    • Prusak-Sochaczewski, E.1    Luong, J.H.T.2    Guilbault, G.G.3
  • 6
    • 0026832837 scopus 로고
    • Development of a piezoelectric immunosensor for the detection of enterobacteria
    • Plomer, M., Guilbault, G. G. & Hock, B., Development of a piezoelectric immunosensor for the detection of enterobacteria. Enzyme Microb. Technol., 14 (1992) 230-5.
    • (1992) Enzyme Microb. Technol. , vol.14 , pp. 230-235
    • Plomer, M.1    Guilbault, G.G.2    Hock, B.3
  • 7
    • 0028372590 scopus 로고
    • A novel immunosensor for herpes viruses
    • Konig, B. & Gratzel, M., A novel immunosensor for herpes viruses. Anal. Chem., 66 (1994) 341-4.
    • (1994) Anal. Chem. , vol.66 , pp. 341-344
    • Konig, B.1    Gratzel, M.2
  • 8
    • 0020538587 scopus 로고
    • ELISA solid phase: Partial denaturation of coating antibody yields a more efficient solid phase
    • Conradie, D. J., Gevender, M. & Visser, L., ELISA solid phase: partial denaturation of coating antibody yields a more efficient solid phase. J. Immunol. Methods, 59 (1983) 289-99.
    • (1983) J. Immunol. Methods , vol.59 , pp. 289-299
    • Conradie, D.J.1    Gevender, M.2    Visser, L.3
  • 9
    • 0023481358 scopus 로고
    • Site-directed immobilization of glycoproteins on hydrazide-containing solid supports
    • O'Shannessy, D. J. & Hoffman, W. L., Site-directed immobilization of glycoproteins on hydrazide-containing solid supports. Biotechnol. Appl. Biochem., 9 (1987) 488-96.
    • (1987) Biotechnol. Appl. Biochem. , vol.9 , pp. 488-496
    • O'Shannessy, D.J.1    Hoffman, W.L.2
  • 10
    • 0029219950 scopus 로고
    • Oriented immobilization of Fab fragments on silica surfaces
    • Lu, B., Xie, J., Lu, C., Wu, C. & Wei, Y., Oriented immobilization of Fab fragments on silica surfaces. Anal. Chem., 67 (1995) 83-7.
    • (1995) Anal. Chem. , vol.67 , pp. 83-87
    • Lu, B.1    Xie, J.2    Lu, C.3    Wu, C.4    Wei, Y.5
  • 11
    • 0021922638 scopus 로고
    • Labelling of colloidal gold with protein A: A quantitative study
    • Horisberger, M. & Clerc, M. F., Labelling of colloidal gold with protein A: a quantitative study. Histochemistry, 82 (1985) 219-33.
    • (1985) Histochemistry , vol.82 , pp. 219-233
    • Horisberger, M.1    Clerc, M.F.2
  • 12
    • 0013992053 scopus 로고
    • "Protein A" from S. aureus. I. Pseudo-immune reaction with human γ-globulin
    • Forsgren, A. & Sjoquist, J., "Protein A" from S. aureus. I. Pseudo-immune reaction with human γ-globulin. J. Immunol., 97 (1966) 822-7.
    • (1966) J. Immunol. , vol.97 , pp. 822-827
    • Forsgren, A.1    Sjoquist, J.2
  • 13
    • 0028854529 scopus 로고
    • A piezoelectric immunosensor for the detection of cortisol
    • Attili, B. S. & Suleiman, A. A., A piezoelectric immunosensor for the detection of cortisol. Anal. Lett., 28 (1995) 2149-59.
    • (1995) Anal. Lett. , vol.28 , pp. 2149-2159
    • Attili, B.S.1    Suleiman, A.A.2
  • 14
    • 0029071409 scopus 로고
    • A piezoelectric immunosensor for hepatitis viruses
    • Konig, B. & Gratzel, M., A piezoelectric immunosensor for hepatitis viruses. Anal. Chim. Acta, 309 (1995) 19-25.
    • (1995) Anal. Chim. Acta , vol.309 , pp. 19-25
    • Konig, B.1    Gratzel, M.2
  • 15
    • 0030058268 scopus 로고    scopus 로고
    • Detection of the red tide-causing plankton Chattonella marina using a piezoelectric immunosensor
    • Nakanishi, K., Karube, I., Hiroshi, S., Uohida, A. & Ishida, Y., Detection of the red tide-causing plankton Chattonella marina using a piezoelectric immunosensor. Anal. Chim, Acta, 325 (1996) 73-80.
    • (1996) Anal. Chim, Acta , vol.325 , pp. 73-80
    • Nakanishi, K.1    Karube, I.2    Hiroshi, S.3    Uohida, A.4    Ishida, Y.5
  • 16
    • 0025335588 scopus 로고
    • A new approach to the development of a reusable piezoelectric crystal biosensor
    • Prusak-Sochaczewski, E. & Luong, J. H. T., A new approach to the development of a reusable piezoelectric crystal biosensor. Anal. Lett., 23 (1990) 401-9.
    • (1990) Anal. Lett. , vol.23 , pp. 401-409
    • Prusak-Sochaczewski, E.1    Luong, J.H.T.2
  • 17
    • 0008288414 scopus 로고
    • The complement system
    • ed. J. A. Bellanti. W.B. Saunders Company, Philadelphia
    • Kunkel, S. L., Ward, P. A., Caporale, L. H. & Vogel, C-W., The complement system. Immunology III, ed. J. A. Bellanti. W.B. Saunders Company, Philadelphia, 1985, pp. 106-16.
    • (1985) Immunology III , pp. 106-116
    • Kunkel, S.L.1    Ward, P.A.2    Caporale, L.H.3    Vogel, C.-W.4
  • 18
    • 0023639408 scopus 로고
    • Piezoelectric crystal biosensor modified with protein A for determination of immunoglobulins
    • Muramatsu, H., Dicks, J. M., Tamiya, E. & Karube, I., Piezoelectric crystal biosensor modified with protein A for determination of immunoglobulins. Anal. Chem., 59 (1987) 2760-3.
    • (1987) Anal. Chem. , vol.59 , pp. 2760-2763
    • Muramatsu, H.1    Dicks, J.M.2    Tamiya, E.3    Karube, I.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.