Novel cardiac assist valve with a purge flow in the valve sinus

Author keywords

[No Author keywords available]

Indexed keywords

CARDIOLOGY; COMPUTATIONAL FLUID DYNAMICS; HEMODYNAMICS;

EID: 0032170022     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002480-199809000-00069     Document Type: Article
Times cited : (11)

References (15)
  • 1
    • 0030038731 scopus 로고    scopus 로고
    • Can we develop a permanent pulsatile rotary blood pump? Yes, we can
    • Poirier VL: Can we develop a permanent pulsatile rotary blood pump? Yes, we can. Artif Organs 20: 475-480, 1996.
    • (1996) Artif Organs , vol.20 , pp. 475-480
    • Poirier, V.L.1
  • 2
    • 0031283317 scopus 로고    scopus 로고
    • Technical obstacles on the road towards a permanent left ventricular assist device
    • New York, Springer Verlag
    • Affeld K, Ziemann A, Goubergrits L: Technical obstacles on the road towards a permanent left ventricular assist device, in Heart and Vessel, New York, Springer Verlag, 1997, pp. 37-39.
    • (1997) Heart and Vessel , pp. 37-39
    • Affeld, K.1    Ziemann, A.2    Goubergrits, L.3
  • 5
    • 0014482889 scopus 로고
    • The fluid mechanics of the aortic valve
    • Bellhouse BJ, Talbot L: The fluid mechanics of the aortic valve. J Fluid Mech 35: 721-735, 1969.
    • (1969) J Fluid Mech , vol.35 , pp. 721-735
    • Bellhouse, B.J.1    Talbot, L.2
  • 6
    • 84974046175 scopus 로고
    • Two-dimensional model experiments on the closing of the aortic valve
    • van Steenhoven AA, van Dongen MEH, Spaan JAE: Two-dimensional model experiments on the closing of the aortic valve. ESAO 3: 127-131, 1976.
    • (1976) ESAO , vol.3 , pp. 127-131
    • Van Steenhoven, A.A.1    Van Dongen, M.E.H.2    Spaan, J.A.E.3
  • 7
    • 0018286866 scopus 로고
    • Model studies of the closing behaviour of the aortic valve
    • van Steenhoven AA, van Dongen MEH: Model studies of the closing behaviour of the aortic valve. J Fluid Mech 90: 21-32, 1979.
    • (1979) J Fluid Mech , vol.90 , pp. 21-32
    • Van Steenhoven, A.A.1    Van Dongen, M.E.H.2
  • 8
    • 0020351446 scopus 로고
    • The effect of some hemodynamic factors on the behavour of the aortic valve
    • van Steenhoven AA, Veenstra PC, Reneman RS: The effect of some hemodynamic factors on the behavour of the aortic valve. J Biomech 15: 941-950, 1982.
    • (1982) J Biomech , vol.15 , pp. 941-950
    • Van Steenhoven, A.A.1    Veenstra, P.C.2    Reneman, R.S.3
  • 9
    • 0026539639 scopus 로고
    • Fluid mechanics of left ventricular assist system outflow housings
    • Sturm C, Li W, Woodard JC, Hwang NH: Fluid mechanics of left ventricular assist system outflow housings. ASAIO J 38: M225-227, 1992.
    • (1992) ASAIO J , vol.38
    • Sturm, C.1    Li, W.2    Woodard, J.C.3    Hwang, N.H.4
  • 10
    • 0344035181 scopus 로고
    • The unileaflet heart valve bioprosthesis: New concept
    • New York, Yorke Medical Books, 1982
    • Gabbay S, Frater RWM: The unileaflet heart valve bioprosthesis: new concept, in Cardiac Bioprosthesis, New York, Yorke Medical Books, 1982, pp. 411-424, 1982.
    • (1982) Cardiac Bioprosthesis , pp. 411-424
    • Gabbay, S.1    Frater, R.W.M.2
  • 12
    • 0027742432 scopus 로고
    • Computer controlled versatile pulse duplicator for precision testing of artificial heart valves
    • Schichl K, Affeld KA: Computer controlled versatile pulse duplicator for precision testing of artificial heart valves. Int J Artif Organs 16: 722-728, 1993.
    • (1993) Int J Artif Organs , vol.16 , pp. 722-728
    • Schichl, K.1    Affeld, K.A.2
  • 14
    • 0024705695 scopus 로고
    • The use of image processing in the investigation of artificial heart valve flow
    • Affeld K, Walker P, Schichl K: The use of image processing in the investigation of artificial heart valve flow. Trans ASAIO 35: 294-298, 1989.
    • (1989) Trans ASAIO , vol.35 , pp. 294-298
    • Affeld, K.1    Walker, P.2    Schichl, K.3