Volumn 98, Issue 9, 1998, Pages 866-872

Assessment of small-diameter aortic mechanical prostheses: Physiological relevance of the Doppler gradient, utility of flow augmentation, and limitations of orifice area estimation

Author keywords

Echocardiography; Hemodynamics; Prosthesis

Indexed keywords

ADULT; AGED; AORTA PROSTHESIS; AORTA STENOSIS; ARTICLE; BIOMECHANICS; BLOOD FLOW; CLINICAL ARTICLE; COMPARATIVE STUDY; DIAGNOSTIC VALUE; DOPPLER ECHOCARDIOGRAPHY; ENERGY EXPENDITURE; FEMALE; HEMODYNAMICS; HUMAN; MALE; MEASUREMENT; MODEL; PRESSURE GRADIENT; PRIORITY JOURNAL; PROSTHESIS FAILURE;

EID: 0032168286     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.98.9.866     Document Type: Article
Times cited : (24)

References (21)
  • 2
    • 0024536693 scopus 로고
    • Pressure recovery distal to a stenosis: Potential cause of gradient "overestimation" by Doppler echocardiography
    • Levine RA, Jimoh A, Cape G, McMillan S, Yoganathan AP, Weyman AE. Pressure recovery distal to a stenosis: potential cause of gradient "overestimation" by Doppler echocardiography. J Am Coll Cardiol. 1989; 13:706-715.
    • (1989) J Am Coll Cardiol. , vol.13 , pp. 706-715
    • Levine, R.A.1    Jimoh, A.2    Cape, G.3    McMillan, S.4    Yoganathan, A.P.5    Weyman, A.E.6
  • 3
    • 0025552864 scopus 로고
    • Discrepancies between Doppler and catheter gradient in aortic prosthetic valves in vitro: A manifestation of localized pressure gradient and pressure recovery
    • Baumgartner H, Khan S, DeRobertis M, Czer L, Maurer G. Discrepancies between Doppler and catheter gradient in aortic prosthetic valves in vitro: a manifestation of localized pressure gradient and pressure recovery. Circulation. 1990;82:1467-1475.
    • (1990) Circulation , vol.82 , pp. 1467-1475
    • Baumgartner, H.1    Khan, S.2    Derobertis, M.3    Czer, L.4    Maurer, G.5
  • 4
    • 0028853909 scopus 로고
    • Pressure recovery in bileaflet heart valve prostheses: Localized high velocities and gradients in central and side orifices with implications for Doppler-catheter gradient relation in aortic and mitral position
    • Vandervoort PM, Greenberg NL, Powell KA, Cosgrove DM, Thomas JD. Pressure recovery in bileaflet heart valve prostheses: localized high velocities and gradients in central and side orifices with implications for Doppler-catheter gradient relation in aortic and mitral position. Circulation. 1995;92:3464-3472.
    • (1995) Circulation , vol.92 , pp. 3464-3472
    • Vandervoort, P.M.1    Greenberg, N.L.2    Powell, K.A.3    Cosgrove, D.M.4    Thomas, J.D.5
  • 5
    • 0027087342 scopus 로고
    • Pitfalls in the interpretation of Doppler gradients in prosthetic valves
    • Khan SS. Pitfalls in the interpretation of Doppler gradients in prosthetic valves. Clin Cardiol. 1992;18:23-28.
    • (1992) Clin Cardiol. , vol.18 , pp. 23-28
    • Khan, S.S.1
  • 6
    • 0021840799 scopus 로고
    • Hydraulic estimation of stenotic orifice area: A correction of the Gorlin formula
    • Cannon SR, Richard KL, Crawford M. Hydraulic estimation of stenotic orifice area: a correction of the Gorlin formula. Circulation. 1985;71: 1170-1178.
    • (1985) Circulation , vol.71 , pp. 1170-1178
    • Cannon, S.R.1    Richard, K.L.2    Crawford, M.3
  • 7
    • 0026487659 scopus 로고
    • In vitro pulsatile flow hemodynamics of five mechanical aortic heart valve prostheses
    • Walker PG, Yoganathan AP. In vitro pulsatile flow hemodynamics of five mechanical aortic heart valve prostheses. Eur J Cardiothorac Surg. 1992; 6(suppl I):I-113-I-123.
    • (1992) Eur J Cardiothorac Surg. , vol.6 , Issue.1 SUPPL.
    • Walker, P.G.1    Yoganathan, A.P.2
  • 9
    • 0024436151 scopus 로고
    • Rest and exercise evaluation of St Jude Medical and Medtronic Hall prostheses: Influence of primary lesion, valvular type, valvular size, and left ventricular function
    • Tatineni S, Barner HB, Pearson AC, Halbe D, Woodruff R, Labovitz AJ. Rest and exercise evaluation of St Jude Medical and Medtronic Hall prostheses: influence of primary lesion, valvular type, valvular size, and left ventricular function. Circulation. 1989;80(suppl I):I-16-I-23.
    • (1989) Circulation , vol.80 , Issue.1 SUPPL.
    • Tatineni, S.1    Barner, H.B.2    Pearson, A.C.3    Halbe, D.4    Woodruff, R.5    Labovitz, A.J.6
  • 12
    • 0023324456 scopus 로고
    • Theoretical evaluation of energy loss methods in the analysis of prosthetic heart valves
    • Leefe S, Gentle C. Theoretical evaluation of energy loss methods in the analysis of prosthetic heart valves. J Biomed Eng. 1987;9:121-127.
    • (1987) J Biomed Eng. , vol.9 , pp. 121-127
    • Leefe, S.1    Gentle, C.2
  • 13
    • 50449114923 scopus 로고
    • Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts
    • Gorlin R, Gorlin SG. Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. Am Heart J. 1951;41:1-29.
    • (1951) Am Heart J. , vol.41 , pp. 1-29
    • Gorlin, R.1    Gorlin, S.G.2
  • 14
    • 0017198809 scopus 로고
    • Determination of pressure gradient in mitral stenosis with a non-invasive ultrasound Doppler technique
    • Holen J, Aaslid R, Landmark K, Simonsen S. Determination of pressure gradient in mitral stenosis with a non-invasive ultrasound Doppler technique. Acta Med Scand. 1976;199:455-460.
    • (1976) Acta Med Scand. , vol.199 , pp. 455-460
    • Holen, J.1    Aaslid, R.2    Landmark, K.3    Simonsen, S.4
  • 17
    • 0024158242 scopus 로고
    • Overestimation by Doppler echocardiography of pressure gradients across Starr-Edwards prosthetic valves in the aortic position
    • Rothbart RM, Smucker ML, Gibson RS. Overestimation by Doppler echocardiography of pressure gradients across Starr-Edwards prosthetic valves in the aortic position. Am J Cardiol. 1988;61:475-476.
    • (1988) Am J Cardiol. , vol.61 , pp. 475-476
    • Rothbart, R.M.1    Smucker, M.L.2    Gibson, R.S.3
  • 18
    • 0024661880 scopus 로고
    • A computerized physiologic pulse duplicator for in-vitro hydrodynamic and ultrasonic studies of prosthetic heart valves
    • Arabia FA, Talbot TL, Stewart SF, Nast EP, Clark RE. A computerized physiologic pulse duplicator for in-vitro hydrodynamic and ultrasonic studies of prosthetic heart valves. Biomed Instrum Technol. 1989;23: 205-215.
    • (1989) Biomed Instrum Technol. , vol.23 , pp. 205-215
    • Arabia, F.A.1    Talbot, T.L.2    Stewart, S.F.3    Nast, E.P.4    Clark, R.E.5
  • 19
    • 84909751872 scopus 로고
    • Bernoulli gradient calculations for mechanical aortic valves: In vitro Doppler study
    • Abstract
    • Yoganathan AP, Jones M, Sahn DJ, Ridgeway A, Jimoh A, Tamura T. Bernoulli gradient calculations for mechanical aortic valves: in vitro Doppler study. Circulation. 1986;74(suppl II):II-391. Abstract.
    • (1986) Circulation , vol.74 , Issue.2 SUPPL.
    • Yoganathan, A.P.1    Jones, M.2    Sahn, D.J.3    Ridgeway, A.4    Jimoh, A.5    Tamura, T.6