메뉴 건너뛰기




Volumn 111, Issue 9, 1998, Pages 344-351

Measurement of the glomerular filtration rate (GFR) after administration of iodine contrast medium with the renalyzer PRX90 in healthy cats and cats with renal diseases;Die messung der glomerulären filtrationsrate (GFR) nach jodkontrastmittelgabe mit dem renalyzer PRX90 bei gesunden und nierenkranken katzen

Author keywords

Cat; Glomerular filtration rate (GFR); Iodine contrast medium; Renal clearance; Renal dysfunction; Renalyzer PRX90

Indexed keywords

ANIMALIA; FELIS CATUS; GLOMERULUS;

EID: 0032162087     PISSN: 00059366     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (37)
  • 1
    • 0022426502 scopus 로고
    • Urinary tract infection due to indwelling bladder catheter in dogs and cats
    • Barsanti, J.A., J. Blue, J. Edmunds (1985): Urinary tract infection due to indwelling bladder catheter in dogs and cats. J. Am. Vet. Med. Assoc. 187, 384-388.
    • (1985) J. Am. Vet. Med. Assoc. , vol.187 , pp. 384-388
    • Barsanti, J.A.1    Blue, J.2    Edmunds, J.3
  • 2
    • 0023947637 scopus 로고
    • Glomerular filtration rate estimated from a single plasma sample after contrast-enhanced radiological examinations
    • Boijsen, M., L. Jacobsson, U. Tylen (1988): Glomerular filtration rate estimated from a single plasma sample after contrast-enhanced radiological examinations. Clin. Physiol. 8, 309-316.
    • (1988) Clin. Physiol. , vol.8 , pp. 309-316
    • Boijsen, M.1    Jacobsson, L.2    Tylen, U.3
  • 3
    • 0018345478 scopus 로고
    • Clinical evaluation of glomerular function: 24-hour creatinine clearance in dogs
    • Bovee, K.C., T. Joyce (1979): Clinical evaluation of glomerular function: 24-hour creatinine clearance in dogs. J. Am. Vet. Med. Assoc. 174, 488-491.
    • (1979) J. Am. Vet. Med. Assoc. , vol.174 , pp. 488-491
    • Bovee, K.C.1    Joyce, T.2
  • 4
    • 0015429594 scopus 로고
    • A simple method for the determination of glomerular filtration rate
    • Bröchner-Mortensen, J. (1972): A simple method for the determination of glomerular filtration rate. Scan. J. Clin. Lab. Invest. 30, 371-374.
    • (1972) Scan. J. Clin. Lab. Invest. , vol.30 , pp. 371-374
    • Bröchner-Mortensen, J.1
  • 5
    • 0026045977 scopus 로고
    • Iohexol clearance for the determination of glomerular filtration rate in clinical practice: Evidence for a new gold standard
    • Brown, S.C.W., P.H. O'Reilley (1991): Iohexol clearance for the determination of glomerular filtration rate in clinical practice: evidence for a new gold standard. J. Urol. 146, 675-679.
    • (1991) J. Urol. , vol.146 , pp. 675-679
    • Brown, S.C.W.1    O'Reilley, P.H.2
  • 8
    • 0019041894 scopus 로고
    • Clinical assessment of renal function in the dog with a reduction in nephron number
    • English, P.B., L.J. Flippich, H.L. Thompson (1980): Clinical assessment of renal function in the dog with a reduction in nephron number. Aust. Vet. J. 56, 305-312.
    • (1980) Aust. Vet. J. , vol.56 , pp. 305-312
    • English, P.B.1    Flippich, L.J.2    Thompson, H.L.3
  • 10
    • 0026195704 scopus 로고
    • Exogenous creatinine clearance as a measure of glomerular filtration rate in dogs with reduced renal mass
    • Finco, D.R., S.A. Brown, W.A. Crowell, J.A. Barsanti (1991): Exogenous creatinine clearance as a measure of glomerular filtration rate in dogs with reduced renal mass. Am. J. Vet. Res. 52, 1029-1032.
    • (1991) Am. J. Vet. Res. , vol.52 , pp. 1029-1032
    • Finco, D.R.1    Brown, S.A.2    Crowell, W.A.3    Barsanti, J.A.4
  • 11
    • 0013637169 scopus 로고
    • Procedure for a simple method of measuring glomerular filtration rate in the dog
    • Finco, D.R., D.B. Coulter, J.A. Barsanti (1982): Procedure for a simple method of measuring glomerular filtration rate in the dog. J. Am. Anim. Hosp. Assoc. 18, 804-806.
    • (1982) J. Am. Anim. Hosp. Assoc. , vol.18 , pp. 804-806
    • Finco, D.R.1    Coulter, D.B.2    Barsanti, J.A.3
  • 12
    • 0030745282 scopus 로고    scopus 로고
    • Was ist gesichert in der Prevention der Kontrastmittelnephropathie?
    • Friedrichsohn, C.B., W. Riegel, H. Köhler (1997): Was ist gesichert in der Prevention der Kontrastmittelnephropathie? Med. Klin. 92, 329-334.
    • (1997) Med. Klin. , vol.92 , pp. 329-334
    • Friedrichsohn, C.B.1    Riegel, W.2    Köhler, H.3
  • 13
    • 3042992536 scopus 로고
    • Clinicopathologic evaluation of early renal disease in dogs
    • Grauer, G.F. (1985): Clinicopathologic evaluation of early renal disease in dogs. Comp. Cont. Educ. Pract. Vet. 7, 32-38.
    • (1985) Comp. Cont. Educ. Pract. Vet. , vol.7 , pp. 32-38
    • Grauer, G.F.1
  • 14
    • 0023825124 scopus 로고
    • Improved silver staining procedure for fast staining in PhastSystem Development Unit. I. Staining of sodium dodecyl sulfate gels
    • Heukeshoven, J., R. Dernick (1988): Improved silver staining procedure for fast staining in PhastSystem Development Unit. I. Staining of sodium dodecyl sulfate gels. Electrophoresis 9, 28-32.
    • (1988) Electrophoresis , vol.9 , pp. 28-32
    • Heukeshoven, J.1    Dernick, R.2
  • 16
    • 0025754452 scopus 로고
    • Plasma disappearance of creatinine as a renal function test in the dog
    • Labato, M.A., L.A. Ross (1991): Plasma disappearance of creatinine as a renal function test in the dog. Res. Vet. Sci. 50, 253-258.
    • (1991) Res. Vet. Sci. , vol.50 , pp. 253-258
    • Labato, M.A.1    Ross, L.A.2
  • 17
    • 0024310070 scopus 로고
    • Comparative evaluation of urographic contrast media, Inulin, and 99mTc-DTPA clearance methods for determination of glomerular filtration rate in clinical transplantation
    • Lewis, R., N. Kerr, C. Van Buren, P. Lowry, C. Sandler, O.H. Frazier. P. Powers, J. Herson, J. Corriere, R. Kerman, B. Kahan (1989): Comparative evaluation of urographic contrast media, Inulin, and 99mTc-DTPA clearance methods for determination of glomerular filtration rate in clinical transplantation. Transplantation 48, 790-796.
    • (1989) Transplantation , vol.48 , pp. 790-796
    • Lewis, R.1    Kerr, N.2    Van Buren, C.3    Lowry, P.4    Sandler, C.5    Frazier, O.H.6    Powers, P.7    Herson, J.8    Corriere, J.9    Kerman, R.10    Kahan, B.11
  • 18
    • 0019879578 scopus 로고
    • Assessment of renal function in the dog
    • MacDougall, D.F. (1981): Assessment of renal function in the dog. Vet. Rec. 108, 232-234.
    • (1981) Vet. Rec. , vol.108 , pp. 232-234
    • MacDougall, D.F.1
  • 19
    • 0017407678 scopus 로고
    • Bioavailability and pharmacokinetics of several dosage forms of ampicillin in the cat
    • Mercer, H.D., R.C. Garg, J.D. Powers (1977): Bioavailability and pharmacokinetics of several dosage forms of ampicillin in the cat. Am. J. Vet. Res. 38, 1353-1359.
    • (1977) Am. J. Vet. Res. , vol.38 , pp. 1353-1359
    • Mercer, H.D.1    Garg, R.C.2    Powers, J.D.3
  • 20
    • 2742560922 scopus 로고    scopus 로고
    • Untersuchungen zum Urinproteinmuster mit der Sodium Dodecyl Sulfat-Polyacrylamid-Gradientengel Elektrophorese (SDS-Page) bei gesunden und nierenkranken Katzen
    • Meyer-Lindenberg A., P. Wohlsein, I. Nolte (1997): Untersuchungen zum Urinproteinmuster mit der Sodium Dodecyl Sulfat-Polyacrylamid-Gradientengel Elektrophorese (SDS-Page) bei gesunden und nierenkranken Katzen. J. Vet. Med. A 44, 39-54.
    • (1997) J. Vet. Med. A , vol.44 , pp. 39-54
    • Meyer-Lindenberg, A.1    Wohlsein, P.2    Nolte, I.3
  • 22
    • 0022529348 scopus 로고
    • Accuracy and reproducibility of a new contrast clearance method for the determination of glomerular filtration rate
    • O'Reilley, P.H., P.J.C. Brooman, P.J. Martin, A.J. Pollard, N.B. Farah, G.C. Mason (1986): Accuracy and reproducibility of a new contrast clearance method for the determination of glomerular filtration rate. Brit. Med. J. 293, 234-236.
    • (1986) Brit. Med. J. , vol.293 , pp. 234-236
    • O'Reilley, P.H.1    Brooman, P.J.C.2    Martin, P.J.3    Pollard, A.J.4    Farah, N.B.5    Mason, G.C.6
  • 23
    • 0014769792 scopus 로고
    • The clearance of creatinine, inulin, paraaminohippurate and phensulphothalein in the cat
    • Osbaldiston, G.W., W. Fuhrmann (1970): The clearance of creatinine, inulin, paraaminohippurate and phensulphothalein in the cat. Can. J. Comp. Med. 34, 138-141.
    • (1970) Can. J. Comp. Med. , vol.34 , pp. 138-141
    • Osbaldiston, G.W.1    Fuhrmann, W.2
  • 26
    • 0019629613 scopus 로고
    • Relationship of selected clinical renal function tests to glomerular filtration rate and renal blood flow in cats
    • Ross, L.A., D.R. Finco (1981): Relationship of selected clinical renal function tests to glomerular filtration rate and renal blood flow in cats. Am. J. Vet. Res. 42, 1704-1710.
    • (1981) Am. J. Vet. Res. , vol.42 , pp. 1704-1710
    • Ross, L.A.1    Finco, D.R.2
  • 27
    • 0022727805 scopus 로고
    • Evaluation of renal function in cats, using quantitative urinanalysis
    • Russo, E.A., G.E. Lees, D. Highthower (1986): Evaluation of renal function in cats, using quantitative urinanalysis. Am. J. Vet. Res. 47, 1308-1312.
    • (1986) Am. J. Vet. Res. , vol.47 , pp. 1308-1312
    • Russo, E.A.1    Lees, G.E.2    Highthower, D.3
  • 28
    • 3042950178 scopus 로고
    • Labordiagnostische Möglichkeiten für Praktiker bei Nierenerkrankungen des Hundes und der Katze. Wien
    • Schwendenwein, I. (1989): Labordiagnostische Möglichkeiten für Praktiker bei Nierenerkrankungen des Hundes und der Katze. Wien. Tierärztl. Mschr. 76, 244-248.
    • (1989) Tierärztl. Mschr. , vol.76 , pp. 244-248
    • Schwendenwein, I.1
  • 33
    • 0019427333 scopus 로고
    • 51Cr-EDTA clearance and its relation to several endogenous parameters of glomerular filtration
    • 51Cr-EDTA clearance and its relation to several endogenous parameters of glomerular filtration. Res Vet Sci 30, 152-157.
    • (1981) Res Vet Sci , vol.30 , pp. 152-157
    • Van Den Brom, W.E.1    Biewenga, W.J.2
  • 36
    • 2442661190 scopus 로고
    • Eignung und Aussagekraft der Jodkontrastmittel-Clearance zur Messung der glomerulären Filtrationsrate beim Hund
    • Westhoff, A., A. Meyer-Lindenberg, I. Nolte, P. Wohlsein, T. Trautwein, W. Grüneberg (1994): Eignung und Aussagekraft der Jodkontrastmittel-Clearance zur Messung der glomerulären Filtrationsrate beim Hund. Kleintier-Prax. 39, 593-606.
    • (1994) Kleintier-Prax. , vol.39 , pp. 593-606
    • Westhoff, A.1    Meyer-Lindenberg, A.2    Nolte, I.3    Wohlsein, P.4    Trautwein, T.5    Grüneberg, W.6
  • 37
    • 0347255953 scopus 로고
    • Messung der glomerulären Filtrationsrate (GFR) beim Hund mittels nichtradioaktiver Jod-Kontrastmittel Clearance durch den Renalyzer PRX90
    • Westhoff, A., A. Meyer-Lindenberg, P. Wohlsein, I. Nolte (1993): Messung der glomerulären Filtrationsrate (GFR) beim Hund mittels nichtradioaktiver Jod-Kontrastmittel Clearance durch den Renalyzer PRX90. Mh. Vet. Med. 48, 573-582.
    • (1993) Mh. Vet. Med. , vol.48 , pp. 573-582
    • Westhoff, A.1    Meyer-Lindenberg, A.2    Wohlsein, P.3    Nolte, I.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.