메뉴 건너뛰기




Volumn 39-40, Issue , 1998, Pages 901-907

Effective tritium processing using polyimide films

Author keywords

[No Author keywords available]

Indexed keywords

CATALYSIS; EXPERIMENTAL REACTORS; MECHANICAL PERMEABILITY; PLASTIC FILMS; POLYIMIDES; POLYMERIC MEMBRANES;

EID: 0032156978     PISSN: 09203796     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0920-3796(97)00198-1     Document Type: Article
Times cited : (27)

References (14)
  • 1
    • 0029394396 scopus 로고
    • Operation experience on safety of tritium process laboratory in Japan Atomic Energy Research Institute
    • M. Yamada, M. Enoeda, T. Honma, T. Hayashi, Y. Matsuda, K. Okuno, Operation experience on safety of tritium process laboratory in Japan Atomic Energy Research Institute, Fusion Technol. 28 (1995) 1376.
    • (1995) Fusion Technol. , vol.28 , pp. 1376
    • Yamada, M.1    Enoeda, M.2    Honma, T.3    Hayashi, T.4    Matsuda, Y.5    Okuno, K.6
  • 3
    • 0002330331 scopus 로고
    • The tritium laboratory Karlsruhe; laboratory design and equipment
    • P. Schira, E. Hutter, G. Jourdan, R.-D. Penzhone, The tritium laboratory Karlsruhe; laboratory design and equipment, Fusion Eng. Des. 18 (1991) 19.
    • (1991) Fusion Eng. Des. , vol.18 , pp. 19
    • Schira, P.1    Hutter, E.2    Jourdan, G.3    Penzhone, R.-D.4
  • 4
    • 0029394365 scopus 로고
    • Design of a second generation secondary enclosure clean-up system
    • A.G. Heics, W.T. Shmayda, Design of a second generation secondary enclosure clean-up system, Fusion Technol. 38 (1995) 1509.
    • (1995) Fusion Technol. , vol.38 , pp. 1509
    • Heics, A.G.1    Shmayda, W.T.2
  • 5
    • 0029392791 scopus 로고
    • Tritium stripping a nitrogen glove box using palladium/zeolite and sales 198TM
    • E. Klein, J.R. Wermer, Tritium stripping a nitrogen glove box using palladium/zeolite and sales 198TM, Fusion Technol. 28 (1995) 1532.
    • (1995) Fusion Technol. , vol.28 , pp. 1532
    • Klein, E.1    Wermer, J.R.2
  • 7
    • 0029393129 scopus 로고
    • Gas separation performance of a hollow-filament type polyimide membrane module for a compact removal system
    • T. Hayashi, M. Yamada, T. Suzuki, Y. Matsuda, K. Okuno, Gas separation performance of a hollow-filament type polyimide membrane module for a compact removal system, Fusion Technol. 28 (1995) 1503.
    • (1995) Fusion Technol. , vol.28 , pp. 1503
    • Hayashi, T.1    Yamada, M.2    Suzuki, T.3    Matsuda, Y.4    Okuno, K.5
  • 9
    • 0030074146 scopus 로고    scopus 로고
    • R&D of a compact detritiation system using a gas separation membrane module for the secondary confinement
    • T. Ishida, T. Hayashi, M. Yamada, T. Suzuki, K. Okuno, R&D of a compact detritiation system using a gas separation membrane module for the secondary confinement, Fusion Technol. 30 (1996) 926.
    • (1996) Fusion Technol. , vol.30 , pp. 926
    • Ishida, T.1    Hayashi, T.2    Yamada, M.3    Suzuki, T.4    Okuno, K.5
  • 10
    • 0029391802 scopus 로고
    • Separation of hydrogen isotopes from nitrogen with polyimide membrane
    • D. Labrune, B. Limacher, H. Guidon, G. Moll, Separation of hydrogen isotopes from nitrogen with polyimide membrane, Fusion Technol. 28 (1995) 676.
    • (1995) Fusion Technol. , vol.28 , pp. 676
    • Labrune, D.1    Limacher, B.2    Guidon, H.3    Moll, G.4
  • 14
    • 0346877963 scopus 로고    scopus 로고
    • International Thermonuclear Experimental Reactor Joint Central Team, October
    • ITER-JCT, Design Description Document: Tritium Plant WBS 3.2, International Thermonuclear Experimental Reactor Joint Central Team, October, 1996.
    • (1996) Design Description Document: Tritium Plant WBS 3.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.