메뉴 건너뛰기




Volumn 53, Issue 2, 1998, Pages 115-121

Fluence measurements applied to 5-20 MeV/amu ion beam dosimetry by simultaneous use of a total-absorption calorimeter and a Faraday cup

Author keywords

A few tens of MeV amu ion beams; Faraday cup; Fluence; Simultaneous use; Total absorption calorimeters; Uncertainty

Indexed keywords

CALORIMETERS; CYCLOTRONS; ELECTRON BEAMS; GAMMA RAYS; ION BEAMS; PARTICLE ACCELERATORS;

EID: 0032146137     PISSN: 0969806X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-806X(98)00015-2     Document Type: Article
Times cited : (3)

References (21)
  • 1
    • 0016949731 scopus 로고
    • Ion beam studies, part II. A calorimetric method for ion beam studies
    • Christodoulides C.E. Ion beam studies, part II. A calorimetric method for ion beam studies. Nucl. Instrum. Methods. 135:1976;13-19.
    • (1976) Nucl. Instrum. Methods. , vol.135 , pp. 13-19
    • Christodoulides, C.E.1
  • 2
    • 0010486332 scopus 로고
    • Advances in calorimetry for radiation dosimetry
    • In: Kase K.R., Bjärngard B.E., Attix F.H. (Eds.), Academic Press, Orlando, FL, ch. 4
    • Domen, S.R., 1987. Advances in calorimetry for radiation dosimetry. In: Kase K.R., Bjärngard B.E., Attix F.H. (Eds.), The Dosimetry of Ionizing Radiation, vol. II. Academic Press, Orlando, FL, ch. 4, pp. 245-320.
    • (1987) The Dosimetry of Ionizing Radiation , vol.2 , pp. 245-320
    • Domen, S.R.1
  • 10
    • 0029702397 scopus 로고    scopus 로고
    • High-energy ion irradiation effects on polymer materials, 3. The sensitivity of cellulose triacetate and poly (methyl methacrylate)
    • Kudoh H., Sasuga T., Seguchi T., Katsumura Y. High-energy ion irradiation effects on polymer materials, 3. The sensitivity of cellulose triacetate and poly (methyl methacrylate). Polymer. 37:1996;2903-2908.
    • (1996) Polymer , vol.37 , pp. 2903-2908
    • Kudoh, H.1    Sasuga, T.2    Seguchi, T.3    Katsumura, Y.4
  • 15
    • 0010487412 scopus 로고
    • LET dependence of cellulose triacetate film dosimeter response for ion beams
    • Institute of Physical and Chemical Research (RIKEN), Saitama, Japan, 22
    • Sunaga, H., Tanaka, R., Yoshida, K., Kohno, I., 1988. LET dependence of cellulose triacetate film dosimeter response for ion beams. RIKEN Accel. Prog. Rep., Institute of Physical and Chemical Research (RIKEN), Saitama, Japan, 22, p. 130.
    • (1988) RIKEN Accel. Prog. Rep. , pp. 130
    • Sunaga, H.1    Tanaka, R.2    Yoshida, K.3    Kohno, I.4
  • 17
    • 84915367526 scopus 로고
    • Methods for measuring dose and beam profiles of processing electron accelerator
    • International Atomic Energy Agency, Vienna, STI/PUB/671, IAEA, Vienna
    • Tanaka, R., Sunaga, H., Agematsu, T., 1985. Methods for measuring dose and beam profiles of processing electron accelerator. In: Proceedings of International Symposium on High-Dose Dosimetry for Radiation Processing, International Atomic Energy Agency, Vienna, 1984. STI/PUB/671, IAEA, Vienna, pp. 317-331.
    • (1984) In: Proceedings of International Symposium on High-Dose Dosimetry for Radiation Processing , pp. 317-331
    • Tanaka, R.1    Sunaga, H.2    Agematsu, T.3
  • 18
    • 0344975586 scopus 로고
    • A simultaneous electron energy and dosimeter calibration method for an electron beam irradiator
    • International Atomic Energy Agency (IAEA), Vienna, STI/PUB/846
    • Tanaka, R., Kojima, T., Sunaga, H., 1991. A simultaneous electron energy and dosimeter calibration method for an electron beam irradiator. In: Proceedings of International Symposium on High-Dose Dosimetry for Radiation Processing. International Atomic Energy Agency (IAEA), Vienna, 1990, STI/PUB/846, pp. 189-201.
    • (1990) In: Proceedings of International Symposium on High-Dose Dosimetry for Radiation Processing , pp. 189-201
    • Tanaka, R.1    Kojima, T.2    Sunaga, H.3
  • 20
    • 0031148917 scopus 로고    scopus 로고
    • Radiochromic film dosimetry for clinical proton beams
    • Vatnitsky S.M. Radiochromic film dosimetry for clinical proton beams. Appl. Radiat. Isot. 48:1997;643-651.
    • (1997) Appl. Radiat. Isot. , vol.48 , pp. 643-651
    • Vatnitsky, S.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.