메뉴 건너뛰기




Volumn 43, Issue 4, 1998, Pages 223-228

The use of titanium mesh sheet in the frontozygomatico-orbital region. Case reports

Author keywords

Case reports; Facial fractures; Reconstructive surgery; Titanium mesh sheet

Indexed keywords

TITANIUM;

EID: 0032135194     PISSN: 00450421     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1834-7819.1998.tb00168.x     Document Type: Article
Times cited : (17)

References (30)
  • 2
    • 0021930711 scopus 로고
    • Experimental and clinical results of new advances in the treatment of facial trauma
    • Ewers R, Härle F. Experimental and clinical results of new advances in the treatment of facial trauma. Plast Reconstr Surg 1985;75:25-31.
    • (1985) Plast Reconstr Surg , vol.75 , pp. 25-31
    • Ewers, R.1    Härle, F.2
  • 3
    • 0022442729 scopus 로고
    • The use of Champy miniplates for osteosynthesis in craniofacial deformities and trauma
    • Jackson IT, Somers PC, Kjar JG. The use of Champy miniplates for osteosynthesis in craniofacial deformities and trauma. Plast Reconstr Surg 1986;77:729-36.
    • (1986) Plast Reconstr Surg , vol.77 , pp. 729-736
    • Jackson, I.T.1    Somers, P.C.2    Kjar, J.G.3
  • 4
    • 0015639144 scopus 로고
    • Osteosynthesis with mimaturized screwed plates in maxillofacial surgery
    • Michelet FX, Deymes J, Dessus B. Osteosynthesis with mimaturized screwed plates in maxillofacial surgery. J Maxillofac Surg 1973;1:79-84.
    • (1973) J Maxillofac Surg , vol.1 , pp. 79-84
    • Michelet, F.X.1    Deymes, J.2    Dessus, B.3
  • 5
    • 0025948561 scopus 로고
    • Titanium mesh (Ti Mesh) osteosynthesis: A fast and adaptable method of semi-rigid fixation
    • Patel MF, Langdon JD. Titanium mesh (Ti Mesh) osteosynthesis: a fast and adaptable method of semi-rigid fixation. Br J Oral Maxillofac Surg 1991;29:316-24.
    • (1991) Br J Oral Maxillofac Surg , vol.29 , pp. 316-324
    • Patel, M.F.1    Langdon, J.D.2
  • 6
    • 2442686812 scopus 로고
    • Vitalium mesh mandibular prosthesis
    • Hahn GW. Vitalium mesh mandibular prosthesis. Prosth Dent 1964;14:777-80.
    • (1964) Prosth Dent , vol.14 , pp. 777-780
    • Hahn, G.W.1
  • 7
    • 0014478474 scopus 로고
    • Mandibular fractures fixation with malleable metal mesh
    • Hahn GW, Corgill DA. Mandibular fractures fixation with malleable metal mesh. J Oral Surg 1969;27:180-94.
    • (1969) J Oral Surg , vol.27 , pp. 180-194
    • Hahn, G.W.1    Corgill, D.A.2
  • 9
    • 0020503013 scopus 로고
    • Treatment of mandibular fractures with malleable titanium mesh plates: A review of 120 cases
    • Cobetto GA, McGlary SA, Zallen RD. Treatment of mandibular fractures with malleable titanium mesh plates: a review of 120 cases. J Oral Maxillofac Surg 1983;41:597-600.
    • (1983) J Oral Maxillofac Surg , vol.41 , pp. 597-600
    • Cobetto, G.A.1    McGlary, S.A.2    Zallen, R.D.3
  • 10
    • 0017069217 scopus 로고
    • Treatment of mandibular fractures with use of malleable titanium mesh: Report of 56 cases
    • Zallen RD, Fitzgerald BE. Treatment of mandibular fractures with use of malleable titanium mesh: report of 56 cases. J Oral Surg 1976;34:748-54.
    • (1976) J Oral Surg , vol.34 , pp. 748-754
    • Zallen, R.D.1    Fitzgerald, B.E.2
  • 11
    • 0018128354 scopus 로고
    • Application of a new type of titanium porosity plate in oral surgery
    • Ito T, Soga K, Maekawa N. Application of a new type of titanium porosity plate in oral surgery. Int J Oral Surg 1978;7:323-6.
    • (1978) Int J Oral Surg , vol.7 , pp. 323-326
    • Ito, T.1    Soga, K.2    Maekawa, N.3
  • 12
    • 0017126722 scopus 로고
    • Reconstruction of defects of the mandible
    • Margolis IB, Smith RI, Davis WC. Reconstruction of defects of the mandible. Surgery 1976;79:638-43.
    • (1976) Surgery , vol.79 , pp. 638-643
    • Margolis, I.B.1    Smith, R.I.2    Davis, W.C.3
  • 13
    • 0020684141 scopus 로고
    • New concepts in the reconstruction of mandibular defects following tumor resection
    • Raveh Y, Strich H, Sutter F, Greiner R. New concepts in the reconstruction of mandibular defects following tumor resection. J Oral Maxillofac Surg 1983;41:3-16.
    • (1983) J Oral Maxillofac Surg , vol.41 , pp. 3-16
    • Raveh, Y.1    Strich, H.2    Sutter, F.3    Greiner, R.4
  • 14
    • 0027180277 scopus 로고
    • Immediate reconstruction following maxillectomy: A new method
    • Tideman H, Samman N, Cheung LK. Immediate reconstruction following maxillectomy: a new method. Int J Oral Maxillofac Surg 1993;22:221-5.
    • (1993) Int J Oral Maxillofac Surg , vol.22 , pp. 221-225
    • Tideman, H.1    Samman, N.2    Cheung, L.K.3
  • 15
    • 0024535598 scopus 로고
    • Free grafting of traumatically displaced or resected mandibular condyles
    • Boyne PJ, Free grafting of traumatically displaced or resected mandibular condyles. J Oral Maxillofac Surg 1989;47:228-32.
    • (1989) J Oral Maxillofac Surg , vol.47 , pp. 228-232
    • Boyne, P.J.1
  • 16
    • 0022726091 scopus 로고
    • Titanium mesh and particulate cancellous bone and marrow grafts to augment the maxillary alveolar ridge
    • Gongloff RK, Cole M, Whitlow W, Boyne PJ. Titanium mesh and particulate cancellous bone and marrow grafts to augment the maxillary alveolar ridge. Int J Oral Maxillofac Surg 1986;15:263-8.
    • (1986) Int J Oral Maxillofac Surg , vol.15 , pp. 263-268
    • Gongloff, R.K.1    Cole, M.2    Whitlow, W.3    Boyne, P.J.4
  • 17
    • 0018873170 scopus 로고
    • Experience with functionally stable plate ostcosynthesis after forward displacement of the upper jaw
    • Hörster W. Experience with functionally stable plate ostcosynthesis after forward displacement of the upper jaw. J Maxillofac Surg 1980;8:176-81.
    • (1980) J Maxillofac Surg , vol.8 , pp. 176-181
    • Hörster, W.1
  • 18
    • 0022487138 scopus 로고
    • Modification of the maxillary step osteotomy and stabilization with titanium mesh
    • Stringer DE, Boyne PJ. Modification of the maxillary step osteotomy and stabilization with titanium mesh. J Oral Maxillofac Surg 1986;44:487-8.
    • (1986) J Oral Maxillofac Surg , vol.44 , pp. 487-488
    • Stringer, D.E.1    Boyne, P.J.2
  • 20
    • 0023709076 scopus 로고
    • The surgical correction of mandibular prognathism using rigid internal fixation - A report of a new technique together with its long-term stability
    • Reitzik M. The surgical correction of mandibular prognathism using rigid internal fixation - a report of a new technique together with its long-term stability. Ann Roy Coll Surg Eng 1988;70:380-5.
    • (1988) Ann Roy Coll Surg Eng , vol.70 , pp. 380-385
    • Reitzik, M.1
  • 21
    • 0022413393 scopus 로고
    • The influence of induced micromovement upon the healing of experimental tibial fractures
    • Goodship AE, Kenwright J. The influence of induced micromovement upon the healing of experimental tibial fractures. J Bone Joint Surg 1985;67B:650-5.
    • (1985) J Bone Joint Surg , vol.67 B , pp. 650-655
    • Goodship, A.E.1    Kenwright, J.2
  • 24
    • 0021932732 scopus 로고
    • A technique for osseous restoration of deficient edentulous maxillary ridges
    • Boyne PJ, Cole MD, Stringer D, Shafqat JP. A technique for osseous restoration of deficient edentulous maxillary ridges. J Oral Maxillofac Surg 1985;43:87-91.
    • (1985) J Oral Maxillofac Surg , vol.43 , pp. 87-91
    • Boyne, P.J.1    Cole, M.D.2    Stringer, D.3    Shafqat, J.P.4
  • 25
    • 0024424057 scopus 로고
    • Stress shielding effect of rigid internal fixation plates on mandibular bone grafts. A photon absorption densitometry and quantitative computerized tomographic evaluation
    • Kennady MC, Tucker MR, Lester GE, Buckley MJ. Stress shielding effect of rigid internal fixation plates on mandibular bone grafts. A photon absorption densitometry and quantitative computerized tomographic evaluation. Int J Oral Maxillofac Surg 1989;18:307-10.
    • (1989) Int J Oral Maxillofac Surg , vol.18 , pp. 307-310
    • Kennady, M.C.1    Tucker, M.R.2    Lester, G.E.3    Buckley, M.J.4
  • 26
    • 0019394993 scopus 로고
    • Effect of plates on cortical hone perfusion
    • Jacobs RR, Rahn BA, Perren SM. Effect of plates on cortical hone perfusion. J Trauma 1981;21:91-5.
    • (1981) J Trauma , vol.21 , pp. 91-95
    • Jacobs, R.R.1    Rahn, B.A.2    Perren, S.M.3
  • 27
    • 0025079047 scopus 로고
    • Production of high quality ground sections of bone containing metal implants to demonstrate osseo-integration: A simplified method
    • Allison RT, Sugar AW. Production of high quality ground sections of bone containing metal implants to demonstrate osseo-integration: a simplified method. Med Lab Sci 1990;47:168-71.
    • (1990) Med Lab Sci , vol.47 , pp. 168-171
    • Allison, R.T.1    Sugar, A.W.2
  • 28
    • 0020620181 scopus 로고
    • The interface zone of inorganic implants in vivo: Titanium implants in bone
    • Albrektsson T, Brånernark PI, Hanson HA, et al. The interface zone of inorganic implants in vivo: titanium implants in bone. Ann Biomed Eng 1983;11.1-27.
    • (1983) Ann Biomed Eng , vol.11 , pp. 1-27
    • Albrektsson, T.1    Brånernark, P.I.2    Hanson, H.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.