메뉴 건너뛰기




Volumn 12, Issue 8, 1998, Pages 1017-1019

Chemical composition of smoke produced by high-frequency electrosurgery in a closed gaseous environment: An in vitro study

Author keywords

Electrosurgical smoke; High frequency electrocoagulation

Indexed keywords

AIR POLLUTANT; ANIMAL; ARTICLE; CHEMISTRY; CULTURE TECHNIQUE; ELECTROSURGERY; ENVIRONMENTAL MONITORING; IN VITRO STUDY; INDOOR AIR POLLUTION; LIVER; MASS FRAGMENTOGRAPHY; METHODOLOGY; OCCUPATIONAL EXPOSURE; RADIOFREQUENCY RADIATION; RISK ASSESSMENT; SENSITIVITY AND SPECIFICITY; SMOKE; SWINE;

EID: 0032134993     PISSN: 09302794     EISSN: None     Source Type: Journal    
DOI: 10.1007/s004649900771     Document Type: Article
Times cited : (137)

References (8)
  • 1
    • 0027723595 scopus 로고
    • Recent advances in high-frequency electrosurgery: Development of automated systems
    • Cuschieri A, Haag R (1993) Recent advances in high-frequency electrosurgery: development of automated systems. J Roy Coll Surg Edinb 38: 354-364
    • (1993) J Roy Coll Surg Edinb , vol.38 , pp. 354-364
    • Cuschieri, A.1    Haag, R.2
  • 2
    • 0030073293 scopus 로고    scopus 로고
    • Preliminary study of electrocautery smoke particles produced in vitro and during laparoscopic procedures
    • DesCouteaux JG, Picard P, Poulin C, Baril M (1996) Preliminary study of electrocautery smoke particles produced in vitro and during laparoscopic procedures. Surg Endosc 19: 152-158
    • (1996) Surg Endosc , vol.19 , pp. 152-158
    • DesCouteaux, J.G.1    Picard, P.2    Poulin, C.3    Baril, M.4
  • 4
    • 85034484294 scopus 로고    scopus 로고
    • The cytotoxicity of electrosurgical smoke produced in an anoxic environment
    • (199?) (in press)
    • Hensman C, Newman EL, Shimi S, Cuschieri A (199?) The cytotoxicity of electrosurgical smoke produced in an anoxic environment. Am J Surg (in press)
    • Am J Surg
    • Hensman, C.1    Newman, E.L.2    Shimi, S.3    Cuschieri, A.4
  • 5
    • 0027645999 scopus 로고
    • Smoke production and smoke reduction in endoscopic surgery: Preliminary report
    • Ott DE (1993) Smoke production and smoke reduction in endoscopic surgery: preliminary report. Endosc Surg Allied Tech 1 230-233
    • (1993) Endosc Surg Allied Tech , vol.1 , pp. 230-233
    • Ott, D.E.1
  • 7
    • 0029773742 scopus 로고    scopus 로고
    • Chemical composition and potential hazards of electrocautery smoke
    • Sagar PM, Meagher S, Sobczak S, Wolff BG (1996) Chemical composition and potential hazards of electrocautery smoke. Br J Surg 83: 1792-1793
    • (1996) Br J Surg , vol.83 , pp. 1792-1793
    • Sagar, P.M.1    Meagher, S.2    Sobczak, S.3    Wolff, B.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.