메뉴 건너뛰기




Volumn 185, Issue 4, 1998, Pages 253-262

Concentration of metal elements in the blood and urine in the patients with cementless total knee arthroplasty

Author keywords

Blood; Cementless; Metal elements; Total knee arthroplasty; Urine

Indexed keywords

CHROMIUM; COBALT; METAL; TITANIUM;

EID: 0032130701     PISSN: 00408727     EISSN: None     Source Type: Journal    
DOI: 10.1620/tjem.185.253     Document Type: Article
Times cited : (42)

References (40)
  • 2
  • 3
    • 0024327043 scopus 로고
    • Molecular mechanism of bone resorption by the osteoclast
    • Baron, R. (1989) Molecular mechanism of bone resorption by the osteoclast. Anat. Rec., 224, 317-324.
    • (1989) Anat. Rec. , vol.224 , pp. 317-324
    • Baron, R.1
  • 4
    • 0020965469 scopus 로고
    • Serum concentrations of chromium, cobalt and nickel after total hip replacement: A six month study
    • Black, J., Maitin, E.C., Gelman, H. & Morris, D.M. (1983) Serum concentrations of chromium, cobalt and nickel after total hip replacement: A six month study. Biomaterials, 4, 160-164.
    • (1983) Biomaterials , vol.4 , pp. 160-164
    • Black, J.1    Maitin, E.C.2    Gelman, H.3    Morris, D.M.4
  • 6
    • 0025695692 scopus 로고
    • The effect of stem stiffness on femoral bone resorption after canine porouscoated total hip arthroplasty
    • Bobyn, J.D., Glassman, A.H., Goto, H., Krygier, J.J., Miller, J.E. & Brooks, C.E. (1990) The effect of stem stiffness on femoral bone resorption after canine porouscoated total hip arthroplasty. Clin. Orthop., 261, 196-213.
    • (1990) Clin. Orthop. , vol.261 , pp. 196-213
    • Bobyn, J.D.1    Glassman, A.H.2    Goto, H.3    Krygier, J.J.4    Miller, J.E.5    Brooks, C.E.6
  • 8
    • 0027474973 scopus 로고
    • Titanium lines: A manifestation of metallosis and tissue response to titanium alloy megaprostheses at the knee
    • Breen, D.J. & Stoker, D.J. (1993) Titanium lines: A manifestation of metallosis and tissue response to titanium alloy megaprostheses at the knee. Clin. Radiol., 47, 274-277.
    • (1993) Clin. Radiol. , vol.47 , pp. 274-277
    • Breen, D.J.1    Stoker, D.J.2
  • 11
    • 0027405754 scopus 로고
    • The clinical results and basic science of total hip arthroplasty with porous-coated prostheses
    • Callaghan, J.J. (1993) The clinical results and basic science of total hip arthroplasty with porous-coated prostheses. J. Bone Joint Surg. Am., 75, 299-310.
    • (1993) J. Bone Joint Surg. Am. , vol.75 , pp. 299-310
    • Callaghan, J.J.1
  • 12
    • 0019997918 scopus 로고
    • Metal concentration in synovial fluids of patients with prosthetic knee arthroplasty
    • Cracchiolo, A. & Revell, P. (1982) Metal concentration in synovial fluids of patients with prosthetic knee arthroplasty. Clin. Orthop., 170, 169-174.
    • (1982) Clin. Orthop. , vol.170 , pp. 169-174
    • Cracchiolo, A.1    Revell, P.2
  • 13
    • 0019128573 scopus 로고
    • Metal ion release after total hip replacement
    • Dobbs, H.S. & Minski, M.J. (1980) Metal ion release after total hip replacement. Biomaterials, 1, 193-198.
    • (1980) Biomaterials , vol.1 , pp. 193-198
    • Dobbs, H.S.1    Minski, M.J.2
  • 14
    • 0025679122 scopus 로고
    • Histologic, biochemical, and ion analysis of tissue and fluids retrieved during total hip arthroplasty
    • Dorr, L.D., Bloebaum, R., Emmanual, J. & Meldnum, R. (1990) Histologic, biochemical, and ion analysis of tissue and fluids retrieved during total hip arthroplasty. Clin. Orthop., 261, 82-95.
    • (1990) Clin. Orthop. , vol.261 , pp. 82-95
    • Dorr, L.D.1    Bloebaum, R.2    Emmanual, J.3    Meldnum, R.4
  • 15
    • 0023777583 scopus 로고
    • The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless total hip arthroplasty
    • Engh, C.A. & Bobyn, J.D. (1988) The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless total hip arthroplasty. Clin. Orthop., 231, 7-28.
    • (1988) Clin. Orthop. , vol.231 , pp. 7-28
    • Engh, C.A.1    Bobyn, J.D.2
  • 16
    • 0018687995 scopus 로고
    • "Modes of failure" of cemented stem-type femoral components: A radiographic analysis of loosening
    • Gruen, T.A., McNeice, G.M. & Amstutz, H.C. (1979) "Modes of failure" of cemented stem-type femoral components: A radiographic analysis of loosening. Clin. Orthop., 141, 17-27.
    • (1979) Clin. Orthop. , vol.141 , pp. 17-27
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 17
    • 0026132108 scopus 로고
    • Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium
    • Harris, W.H. (1991) Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium [letter, comment]. J. Bone Joint Surg. Am., 73, 470-472.
    • (1991) J. Bone Joint Surg. Am. , vol.73 , pp. 470-472
    • Harris, W.H.1
  • 18
    • 0024110249 scopus 로고
    • Effects of polymethylmethacrylate exposure upon macrophages
    • Horowitz, S.M., Frondoza, C.G. & Lennox, D.W. (1988) Effects of polymethylmethacrylate exposure upon macrophages. J. Orthop. Res., 6, 827-832.
    • (1988) J. Orthop. Res. , vol.6 , pp. 827-832
    • Horowitz, S.M.1    Frondoza, C.G.2    Lennox, D.W.3
  • 19
    • 0027260321 scopus 로고
    • Studies of the mechanism by which the mechanical failure of polymethylmethacrylate leads to bone resorption
    • Horowitz, S.M., Doty, S.B., Lane, J.M. & Burstein, A.H. (1993) Studies of the mechanism by which the mechanical failure of polymethylmethacrylate leads to bone resorption. J. Bone Joint Surg. Am., 75, 802-813.
    • (1993) J. Bone Joint Surg. Am. , vol.75 , pp. 802-813
    • Horowitz, S.M.1    Doty, S.B.2    Lane, J.M.3    Burstein, A.H.4
  • 20
    • 0039368762 scopus 로고
    • Urinary metal ion levels in patients implanted with porous coated total hip prostheses
    • Jones, L.C. & Hungerford, D.S. (1987) Urinary metal ion levels in patients implanted with porous coated total hip prostheses. Trans. Orthop. Res. Soc., 32, 317.
    • (1987) Trans. Orthop. Res. Soc. , vol.32 , pp. 317
    • Jones, L.C.1    Hungerford, D.S.2
  • 24
    • 0024330679 scopus 로고
    • Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium-alloy modular femoral heads
    • Lombardi, A.V., Mallory, T.H. & Vaughn, B.K. (1989) Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium-alloy modular femoral heads. J. Bone Joint Surg. Am., 71, 1337-1342.
    • (1989) J. Bone Joint Surg. Am. , vol.71 , pp. 1337-1342
    • Lombardi, A.V.1    Mallory, T.H.2    Vaughn, B.K.3
  • 25
    • 0029120016 scopus 로고
    • Periprosthetic osteolysis in total hip arthroplasty: The role of particulate wear debris
    • Maloney, W.J. & Smith, R.L. (1995) Periprosthetic osteolysis in total hip arthroplasty: The role of particulate wear debris. J. Bone Joint Surg. Am., 77, 1448-1461.
    • (1995) J. Bone Joint Surg. Am. , vol.77 , pp. 1448-1461
    • Maloney, W.J.1    Smith, R.L.2
  • 26
    • 0026454751 scopus 로고
    • Severe metallosis due to abnormal abrasion of the femoral head in a dual bearing hip prosthesis. A case report
    • Matsuda, Y., Yamamuro, T., Kasai, R., Matsusue, Y. & Okumura, H. (1992) Severe metallosis due to abnormal abrasion of the femoral head in a dual bearing hip prosthesis. A case report. J. Arthroplasty, 7, 439-445.
    • (1992) J. Arthroplasty , vol.7 , pp. 439-445
    • Matsuda, Y.1    Yamamuro, T.2    Kasai, R.3    Matsusue, Y.4    Okumura, H.5
  • 27
    • 0026013091 scopus 로고
    • Systemic effects of implanted prostheses made of cobalt-chromium alloys
    • Michel, R., Nolte, M., Reich, M. & Loer, F. (1991) Systemic effects of implanted prostheses made of cobalt-chromium alloys. Arch. Orthop. Trauma Surg., 110, 61-74.
    • (1991) Arch. Orthop. Trauma Surg. , vol.110 , pp. 61-74
    • Michel, R.1    Nolte, M.2    Reich, M.3    Loer, F.4
  • 28
    • 0016968013 scopus 로고
    • The pathology of the joint tissue and its clinical relevance in prosthesis failure
    • Mirra, J.M., Amstutz, H.C., Matos, M. & Gold, R. (1976) The pathology of the joint tissue and its clinical relevance in prosthesis failure. Clin. Orthop., 117, 221-240.
    • (1976) Clin. Orthop. , vol.117 , pp. 221-240
    • Mirra, J.M.1    Amstutz, H.C.2    Matos, M.3    Gold, R.4
  • 30
    • 0016803288 scopus 로고
    • A study on the effects of particulate metals of orthopaedic interest on murine macrophages in vitro
    • Rae, T. (1975) A study on the effects of particulate metals of orthopaedic interest on murine macrophages in vitro. J. Bone Joint Surg. Br., 57, 444-450.
    • (1975) J. Bone Joint Surg. Br. , vol.57 , pp. 444-450
    • Rae, T.1
  • 31
    • 0022570775 scopus 로고
    • The biological response to titanium and titanium-aluminum-vanadium alloy particles
    • Rae, T. (1986) The biological response to titanium and titanium-aluminum-vanadium alloy particles. Biomaterials, 7, 30-36.
    • (1986) Biomaterials , vol.7 , pp. 30-36
    • Rae, T.1
  • 32
    • 0027296132 scopus 로고
    • Particulate metallic debris in cemented total hip arthroplasty
    • Salvati, E.A., Betts, F. & Doty, S.B. (1993) Particulate metallic debris in cemented total hip arthroplasty. Clin. Orthop., 293, 160-173.
    • (1993) Clin. Orthop. , vol.293 , pp. 160-173
    • Salvati, E.A.1    Betts, F.2    Doty, S.B.3
  • 35
    • 0001033238 scopus 로고
    • Metal ion release after porous total knee arthroplasty: A prospective controlled assessment
    • Stulberg, B.N., Watson, J.T. & Shull, S.L. (1987) Metal ion release after porous total knee arthroplasty: A prospective controlled assessment. Trans. Orthop. Res. Soc., 33, 314.
    • (1987) Trans. Orthop. Res. Soc. , vol.33 , pp. 314
    • Stulberg, B.N.1    Watson, J.T.2    Shull, S.L.3
  • 37
    • 0018890994 scopus 로고
    • Mononucleus phagocytes, osteoclasts and bone resorption
    • Tetlebaum, S.L. & Kahn, A.J. (1980) Mononucleus phagocytes, osteoclasts and bone resorption. Miner. Electro. Metab., 3, 2-9.
    • (1980) Miner. Electro. Metab. , vol.3 , pp. 2-9
    • Tetlebaum, S.L.1    Kahn, A.J.2
  • 39
    • 0025874154 scopus 로고
    • Metal wear and tissue response in failed titanium alloy total hip replacements
    • Witt, J.D. & Swann, M. (1991) Metal wear and tissue response in failed titanium alloy total hip replacements. J. Bone Joint Surg. Br., 73, 559-563.
    • (1991) J. Bone Joint Surg. Br. , vol.73 , pp. 559-563
    • Witt, J.D.1    Swann, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.