메뉴 건너뛰기




Volumn 31, Issue 4, 1998, Pages 268-274

Shaping ability of Quantec Series 2000 rotary nickel-titanium instruments in simulated root canals: Part 2

Author keywords

Aberrations; Canal shaping; Endodontics; Nickel titanium; Root canals; Rotary instruments

Indexed keywords

NICKEL; TITANIUM; TITANIUM NICKELIDE;

EID: 0032128703     PISSN: 01432885     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-2591.1998.00152.x     Document Type: Article
Times cited : (41)

References (21)
  • 2
    • 0024757225 scopus 로고
    • The validity of using simulated root canals as models for ultrasonic instrumentation
    • AHMAD M (1989) The validity of using simulated root canals as models for ultrasonic instrumentation. Journal of Endodontics 15, 544-7.
    • (1989) Journal of Endodontics , vol.15 , pp. 544-547
    • Ahmad, M.1
  • 3
    • 0024660425 scopus 로고
    • Shaping of simulated root canals in resin blocks using the step-back technique with K-flles manipulated in a simple in/out motion
    • ALODEH MHA, DOLLER R, DUMMER PMH (1989) Shaping of simulated root canals in resin blocks using the step-back technique with K-flles manipulated in a simple in/out motion. International Endodontic Journal 22, 107-17.
    • (1989) International Endodontic Journal , vol.22 , pp. 107-117
    • Alodeh, M.H.A.1    Doller, R.2    Dummer, P.M.H.3
  • 4
    • 0024725671 scopus 로고
    • A comparison of the ability of K-files and Hedstrom files to shape simulated root canals in resin blocks
    • ALODEH MHA, DUMMER PMH (1989) A comparison of the ability of K-files and Hedstrom files to shape simulated root canals in resin blocks. International Endodontic Journal 22, 226-35.
    • (1989) International Endodontic Journal , vol.22 , pp. 226-235
    • Alodeh, M.H.A.1    Dummer, P.M.H.2
  • 6
    • 0024723451 scopus 로고
    • Shaping of simulated root canals in resin blocks using files activated by a sonic hand-piece
    • DUMMER PMH, ALODEH MHA, DOLLER R (1989) Shaping of simulated root canals in resin blocks using files activated by a sonic hand-piece. International Endodontic Journal 5, 211-25.
    • (1989) International Endodontic Journal , vol.5 , pp. 211-225
    • Dummer, P.M.H.1    Alodeh, M.H.A.2    Doller, R.3
  • 8
    • 0027597444 scopus 로고
    • Comparison of two sonic hand-pieces during the preparation of simulated root canals
    • DUMMER PMH, HUTCHINGS R, HARTLES FR (1993) Comparison of two sonic hand-pieces during the preparation of simulated root canals. International Endodontic Journal 26, 159-68.
    • (1993) International Endodontic Journal , vol.26 , pp. 159-168
    • Dummer, P.M.H.1    Hutchings, R.2    Hartles, F.R.3
  • 9
    • 0021982743 scopus 로고
    • The effect of different files on the preparation shape of severely curved canals
    • ELDEEB ME, BORAAS JC (1985) The effect of different files on the preparation shape of severely curved canals. International Endodontic Journal 18, 1-7.
    • (1985) International Endodontic Journal , vol.18 , pp. 1-7
    • Eldeeb, M.E.1    Boraas, J.C.2
  • 10
    • 0029283312 scopus 로고
    • A comparison of canal preparation with nickel-titanium and stainless steel instruments
    • ESPOSITO PT, CUNNINGHAM CJ (1995) A comparison of canal preparation with nickel-titanium and stainless steel instruments. Journal of Endodontics 21, 173-6.
    • (1995) Journal of Endodontics , vol.21 , pp. 173-176
    • Esposito, P.T.1    Cunningham, C.J.2
  • 11
    • 0029264974 scopus 로고
    • A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven and K-Flex endodontic instruments
    • GLOSSON CR, HALLER RH, DOVE SB, DEL RIO CE (1995) A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven and K-Flex endodontic instruments. Journal of Endodontics 21, 146-51.
    • (1995) Journal of Endodontics , vol.21 , pp. 146-151
    • Glosson, C.R.1    Haller, R.H.2    Dove, S.B.3    Del Rio, C.E.4
  • 12
    • 0020346392 scopus 로고
    • Instrumentation of root canals in molars using a step-down technique
    • GOERIG AC, MICHELICH RJ, SCHULTZ HH (1982) Instrumentation of root canals in molars using a step-down technique. Journal of Endodontics 8, 550-4.
    • (1982) Journal of Endodontics , vol.8 , pp. 550-554
    • Goerig, A.C.1    Michelich, R.J.2    Schultz, H.H.3
  • 13
    • 0022141717 scopus 로고
    • The validity of simulated root canals for the investigation of the prepared root canal shape
    • LIM SS, WEBBER J (1985) The validity of simulated root canals for the investigation of the prepared root canal shape. International Endodontic Journal 18, 240-6.
    • (1985) International Endodontic Journal , vol.18 , pp. 240-246
    • Lim, S.S.1    Webber, J.2
  • 14
    • 0022068379 scopus 로고
    • The 'balanced force' concept of instrumentation of curved canals
    • ROANE JB, SABALA CL, DUNCANSON MG (1985) The 'balanced force' concept of instrumentation of curved canals. Journal of Endodontics 11, 203-11.
    • (1985) Journal of Endodontics , vol.11 , pp. 203-211
    • Roane, J.B.1    Sabala, C.L.2    Duncanson, M.G.3
  • 15
    • 0039786250 scopus 로고
    • Canal debridement and disinfection
    • COHEN S, BURNS RC, eds: St Louis: The CV Mosby Company
    • SCHILDER H, YEE FS (1984) Canal debridement and disinfection. In COHEN S, BURNS RC, eds: Pathways of the Pulp. 3rd edn., 175, St Louis: The CV Mosby Company.
    • (1984) Pathways of the Pulp. 3rd Edn. , pp. 175
    • Schilder, H.1    Yee, F.S.2
  • 16
    • 0030622001 scopus 로고    scopus 로고
    • Shaping ability of ProFile 0.04 Taper Series 29 rotary nickel-titanium instruments in simulated root canals. Part 2
    • THOMPSON SA, DUMMER PMH (1997) Shaping ability of ProFile 0.04 Taper Series 29 rotary nickel-titanium instruments in simulated root canals. Part 2. International Endodontic Journal 30, 8-15.
    • (1997) International Endodontic Journal , vol.30 , pp. 8-15
    • Thompson, S.A.1    Dummer, P.M.H.2
  • 17
    • 0031301819 scopus 로고    scopus 로고
    • Shaping ability of Lightspeed rotary nickel-titanium instruments in simulated root canals. Part 2
    • THOMPSON SA, DUMMER PMH (1998a) Shaping ability of Lightspeed rotary nickel-titanium instruments in simulated root canals. Part 2. Journal of Endodontics 23, 742-7.
    • (1998) Journal of Endodontics , vol.23 , pp. 742-747
    • Thompson, S.A.1    Dummer, P.M.H.2
  • 18
    • 0031990192 scopus 로고    scopus 로고
    • Shaping ability of Mity Roto 360° and Naviflex rotary nickel-titanium instruments in simulated root canals. Part 2
    • in press
    • THOMPSON SA, DUMMER PMH (1998b) Shaping ability of Mity Roto 360° and Naviflex rotary nickel-titanium instruments in simulated root canals. Part 2. Journal of Endodontics, in press.
    • (1998) Journal of Endodontics
    • Thompson, S.A.1    Dummer, P.M.H.2
  • 19
    • 0031174854 scopus 로고    scopus 로고
    • Shaping ability of NT Engine and McXim rotary nickel-titanium instruments in simulated root canals. Part 2
    • THOMPSON SA, DUMMER PMH (1998c) Shaping ability of NT Engine and McXim rotary nickel-titanium instruments in simulated root canals. Part 2. International Endodontic Journal 30, 270-8.
    • (1998) International Endodontic Journal , vol.30 , pp. 270-278
    • Thompson, S.A.1    Dummer, P.M.H.2
  • 20
    • 0032128947 scopus 로고    scopus 로고
    • Shaping ability of Quantec Series 2000 rotary nickel-titanium instruments in simulated root canals. Part 1
    • THOMPSON SA, DUMMER PMH (1998d) Shaping ability of Quantec Series 2000 rotary nickel-titanium instruments in simulated root canals. Part 1. International Endodontic Journal 31, 259-67.
    • (1998) International Endodontic Journal , vol.31 , pp. 259-267
    • Thompson, S.A.1    Dummer, P.M.H.2
  • 21
    • 0016545006 scopus 로고
    • The effect of preparation procedures on original canal shape and on apical foramen shape
    • WEINE FS, KELLY RF, LIO PJ (1975) The effect of preparation procedures on original canal shape and on apical foramen shape. Journal of Endodontics 1, 255-62.
    • (1975) Journal of Endodontics , vol.1 , pp. 255-262
    • Weine, F.S.1    Kelly, R.F.2    Lio, P.J.3