메뉴 건너뛰기




Volumn 75, Issue 7, 1998, Pages 513-517

False-response monitoring during automated perimetry

Author keywords

Accuracy; Automated perimetry; Catch trials; False response; Precision; Reliability

Indexed keywords

COMPUTER SOFTWARE; DATA REDUCTION; FUNCTIONAL ASSESSMENT;

EID: 0032127495     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/00006324-199807000-00020     Document Type: Article
Times cited : (20)

References (10)
  • 2
    • 0027771583 scopus 로고
    • A new reliability parameter for automated perimetry: Inconsistent responses
    • Lee M, Zulauf M, Caprioli J. A new reliability parameter for automated perimetry: inconsistent responses. J Glaucoma 1993;2:279-84.
    • (1993) J Glaucoma , vol.2 , pp. 279-284
    • Lee, M.1    Zulauf, M.2    Caprioli, J.3
  • 3
    • 0001407523 scopus 로고
    • Maximum likelihood estimation of the frequency of false positive and false negative answers from the up- And-down staircases of computerized threshold perimetry
    • Heijl A, ed. Vancouver (Canada), May 9-12, 1988. Amsterdam: Kugler & Ghedini
    • Olsson J, Rootzén H, Heijl A. Maximum likelihood estimation of the frequency of false positive and false negative answers from the up- and-down staircases of computerized threshold perimetry. In: Heijl A, ed. Perimetry Update, 1988/89: Proceedings of the VIIIth International Perimetric Society Meeting, Vancouver (Canada), May 9-12, 1988. Amsterdam: Kugler & Ghedini, 1989:245-51.
    • (1989) Perimetry Update, 1988/89: Proceedings of the VIIIth International Perimetric Society Meeting , pp. 245-251
    • Olsson, J.1    Rootzén, H.2    Heijl, A.3
  • 4
    • 0028325295 scopus 로고
    • Eye movements during perimetry and the effect that fixational instability has on perimetric outcomes
    • Demirel S, Vingrys AJ. Eye movements during perimetry and the effect that fixational instability has on perimetric outcomes. J Glaucoma 1994;3:28-35.
    • (1994) J Glaucoma , vol.3 , pp. 28-35
    • Demirel, S.1    Vingrys, A.J.2
  • 5
    • 0027716210 scopus 로고
    • Characteristics of frequency-of-seeing curves in normal subjects, patients with suspected glaucoma and patients with glaucoma
    • Chauhan BC, Tompkins JD, LeBlanc RP, McCormick TA. Characteristics of frequency-of-seeing curves in normal subjects, patients with suspected glaucoma and patients with glaucoma. Invest Ophthalmol Vis Sci 1993;34:3534-40.
    • (1993) Invest Ophthalmol Vis Sci , vol.34 , pp. 3534-3540
    • Chauhan, B.C.1    Tompkins, J.D.2    Leblanc, R.P.3    McCormick, T.A.4
  • 8
    • 0025368583 scopus 로고
    • The Opticom M-600: A new LED automated perimeter
    • Vingrys AJ, Helfrich KA. The Opticom M-600: a new LED automated perimeter. Clin Exp Optom 1990;73:3-17.
    • (1990) Clin Exp Optom , vol.73 , pp. 3-17
    • Vingrys, A.J.1    Helfrich, K.A.2
  • 9
    • 0020601188 scopus 로고
    • Changes in differential threshold in patients with glaucoma during prolonged perimetry
    • Heijl A, Drance SM. Changes in differential threshold in patients with glaucoma during prolonged perimetry. Br J Ophthalmol 1983;67:512-6.
    • (1983) Br J Ophthalmol , vol.67 , pp. 512-516
    • Heijl, A.1    Drance, S.M.2
  • 10
    • 84920317860 scopus 로고
    • The effect of test duration on catch trial responses in automated perimetry
    • Katz J, Gilbert D, Quigley HA, Sommer A. The effect of test duration on catch trial responses in automated perimetry. J Glaucoma 1992;1:72-8.
    • (1992) J Glaucoma , vol.1 , pp. 72-78
    • Katz, J.1    Gilbert, D.2    Quigley, H.A.3    Sommer, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.