메뉴 건너뛰기




Volumn 41, Issue 1, 1998, Pages 154-161

In vitro biocompatibility assessment of a nickel-titanium alloy using electron microscopy in situ end-labeling (EM-ISEL)

Author keywords

Biocompatibility; Electron microscopy; Genotoxicity; Immunogold labeling; Nickel titanium

Indexed keywords

BIOCOMPATIBILITY; CHROMOSOMES; ELECTRON MICROSCOPY; GENES; IMMUNOLOGY; NICKEL ALLOYS; TITANIUM ALLOYS;

EID: 0032126424     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(199807)41:1<154::AID-JBM18>3.0.CO;2-N     Document Type: Article
Times cited : (44)

References (40)
  • 1
    • 36849132052 scopus 로고
    • Effects of low temperature phase changes on the mechanical properties of alloys near composition TiNi
    • W. J. Buehler, J. V. Gilfrick, and R. C. Wiley, "Effects of low temperature phase changes on the mechanical properties of alloys near composition TiNi," J. Appl. Phys., 34, 1475-1477 (1963).
    • (1963) J. Appl. Phys. , vol.34 , pp. 1475-1477
    • Buehler, W.J.1    Gilfrick, J.V.2    Wiley, R.C.3
  • 2
    • 49949123492 scopus 로고
    • A summary of recent research on the nitinol alloys and their potential applications in ocean engineering
    • W. J. Buehler and F. E. Wang, "A summary of recent research on the nitinol alloys and their potential applications in ocean engineering," Ocean Eng., 1, 105-120 (1968).
    • (1968) Ocean Eng. , vol.1 , pp. 105-120
    • Buehler, W.J.1    Wang, F.E.2
  • 3
    • 0016662355 scopus 로고
    • Potential applications of certain nickel-titanium (nitinol) alloys
    • S. Civjan, E. F. Huget, and L. B. DeSimon, "Potential applications of certain nickel-titanium (nitinol) alloys," J. Dent. Res., 54, 89-96 (1975).
    • (1975) J. Dent. Res. , vol.54 , pp. 89-96
    • Civjan, S.1    Huget, E.F.2    DeSimon, L.B.3
  • 4
    • 0015072885 scopus 로고
    • An evaluation of 55-cobalt substituted nitinol wire for use in orthodontics
    • G. F. Andreasen and T. B. Hilleman, "An evaluation of 55-cobalt substituted nitinol wire for use in orthodontics," J. Am. Dent. Assoc., 82, 1373-1375 (1971).
    • (1971) J. Am. Dent. Assoc. , vol.82 , pp. 1373-1375
    • Andreasen, G.F.1    Hilleman, T.B.2
  • 6
    • 0017015723 scopus 로고
    • Using the shape recovery of nitinol in the Harrington rod treatment of scoliosis
    • M. A. Schmerling, M. A. Milkov, A. E. Sanders, and J. E. Woosley, "Using the shape recovery of nitinol in the Harrington rod treatment of scoliosis," J. Biomed. Mater. Res., 10, 879-892 (1976).
    • (1976) J. Biomed. Mater. Res. , vol.10 , pp. 879-892
    • Schmerling, M.A.1    Milkov, M.A.2    Sanders, A.E.3    Woosley, J.E.4
  • 8
    • 0027261289 scopus 로고
    • A preliminary investigation of shape memory alloys in the surgical correction of scoliosis
    • J. O. Sanders, A. E. Sanders, R. More, and R. B. Ashman, "A preliminary investigation of shape memory alloys in the surgical correction of scoliosis," Spine, 18, 1640-1646 (1993).
    • (1993) Spine , vol.18 , pp. 1640-1646
    • Sanders, J.O.1    Sanders, A.E.2    More, R.3    Ashman, R.B.4
  • 10
    • 0027342981 scopus 로고
    • Biodegradation of orthodontic appliances. Part I. Biodegradation of nickel and chromium in vitro
    • R. D. Barrett, S. E. Bishara, and J. K. Quinn, "Biodegradation of orthodontic appliances. Part I. Biodegradation of nickel and chromium in vitro," Am. J. Orthod. Dentofacial Orthop., 103, 8-14 (1993).
    • (1993) Am. J. Orthod. Dentofacial Orthop. , vol.103 , pp. 8-14
    • Barrett, R.D.1    Bishara, S.E.2    Quinn, J.K.3
  • 11
    • 0027548469 scopus 로고
    • Biodegradation of orthodontic appliances. Part II. Changes in the blood level of nickel
    • S. E. Bishara, R. D. Barrett, and M. I. Selim, "Biodegradation of orthodontic appliances. Part II. Changes in the blood level of nickel," Am. J. Orthod. Dentofacial Orthop., 103, 115-119 (1993).
    • (1993) Am. J. Orthod. Dentofacial Orthop. , vol.103 , pp. 115-119
    • Bishara, S.E.1    Barrett, R.D.2    Selim, M.I.3
  • 12
    • 0028789346 scopus 로고
    • Comparative carcinogenic effects of nickel subsulfides, nickel oxide, or nickel sulfate hexahydrate chronic exposures in the lung
    • J. K. Dunnick, M. R. Elwell, A. E. Radovsky, J. M. Benson, F. F. Hahn, K. J. Nikula, E. B. Barr, and C. H. Hobbs, "Comparative carcinogenic effects of nickel subsulfides, nickel oxide, or nickel sulfate hexahydrate chronic exposures in the lung," Cancer Res., 55, 5251-5256 (1995).
    • (1995) Cancer Res. , vol.55 , pp. 5251-5256
    • Dunnick, J.K.1    Elwell, M.R.2    Radovsky, A.E.3    Benson, J.M.4    Hahn, F.F.5    Nikula, K.J.6    Barr, E.B.7    Hobbs, C.H.8
  • 13
    • 0028239748 scopus 로고
    • Mechanisms in nickel genotoxicity: The significance of interactions with DNA repair
    • A. Hartwig, I. Kruger, and D. Beyersmann, "Mechanisms in nickel genotoxicity: The significance of interactions with DNA repair," Toxicology Lett., 72, 353-358 (1994).
    • (1994) Toxicology Lett. , vol.72 , pp. 353-358
    • Hartwig, A.1    Kruger, I.2    Beyersmann, D.3
  • 14
    • 0028071247 scopus 로고
    • Nickel(II) interferes with the incision step in nucleotide excision repair in mammalian cells
    • A. Hartwig, L. H. F. Mullenders, R. Schlepegrell, U. Kasten, and D. Beyersmann, "Nickel(II) interferes with the incision step in nucleotide excision repair in mammalian cells," Cancer Res., 54, 4045-4051 (1994).
    • (1994) Cancer Res. , vol.54 , pp. 4045-4051
    • Hartwig, A.1    Mullenders, L.H.F.2    Schlepegrell, R.3    Kasten, U.4    Beyersmann, D.5
  • 16
    • 0025108239 scopus 로고
    • High-resolution dynamic and morphological G-bandings (GBG and GTG): A comparative study
    • N. Lemieux, R. Drouin, and C. L. Richer, "High-resolution dynamic and morphological G-bandings (GBG and GTG): A comparative study," Hum. Genet., 85, 261-266 (1990).
    • (1990) Hum. Genet. , vol.85 , pp. 261-266
    • Lemieux, N.1    Drouin, R.2    Richer, C.L.3
  • 17
    • 0031311308 scopus 로고    scopus 로고
    • Immunogold electron microscopy in situ end-labeling (EM-ISEL) assay for biomaterial DNA damage detection
    • to appear
    • M. Assad, N. Lemieux, and C. H. Rivard, "Immunogold electron microscopy in situ end-labeling (EM-ISEL) assay for biomaterial DNA damage detection," Biomed. Mater. Eng., to appear.
    • Biomed. Mater. Eng.
    • Assad, M.1    Lemieux, N.2    Rivard, C.H.3
  • 18
    • 0022872823 scopus 로고
    • Easy transfer of selected mitoses from light to electron microscopy
    • P. E. Messier, P. Jean, and C. L. Richer, "Easy transfer of selected mitoses from light to electron microscopy," Cytogenet. Cell Genet., 43, 207-210 (1986).
    • (1986) Cytogenet. Cell Genet. , vol.43 , pp. 207-210
    • Messier, P.E.1    Jean, P.2    Richer, C.L.3
  • 19
    • 0030152618 scopus 로고    scopus 로고
    • Cytocompatibility of Ti-6Al-4V and Ti-5Al-2.5Fe alloys according to three surface treatments, using human fibroblasts and osteoblasts
    • K. Bordji, J. Y. Jouzeau, D. Mainard, E. Payan, P. Netter, K. T. Rie, T. Stucky, and M. Hage-Ali, "Cytocompatibility of Ti-6Al-4V and Ti-5Al-2.5Fe alloys according to three surface treatments, using human fibroblasts and osteoblasts," Biomaterials, 17, 929-940 (1996).
    • (1996) Biomaterials , vol.17 , pp. 929-940
    • Bordji, K.1    Jouzeau, J.Y.2    Mainard, D.3    Payan, E.4    Netter, P.5    Rie, K.T.6    Stucky, T.7    Hage-Ali, M.8
  • 20
    • 0028813516 scopus 로고
    • Titanium as the material of choice for cementless femoral components in total hip arthroplasty
    • W. C. Head, D. J. Bauk, and R. H. Emerson, Jr., "Titanium as the material of choice for cementless femoral components in total hip arthroplasty," Clin. Orthop. Rel. Res., 311, 85-90 (1995).
    • (1995) Clin. Orthop. Rel. Res. , vol.311 , pp. 85-90
    • Head, W.C.1    Bauk, D.J.2    Emerson Jr., R.H.3
  • 21
    • 0028434177 scopus 로고
    • Evaluation of carcinogenicity and chronic toxicity associated with orthopedic implants in mice
    • K. Takamura, K. Hayashi, N. Ishinishi, T. Yamada, and Y. Sugioka, "Evaluation of carcinogenicity and chronic toxicity associated with orthopedic implants in mice," J. Biomed. Mater. Res., 28, 583-589 (1994).
    • (1994) J. Biomed. Mater. Res. , vol.28 , pp. 583-589
    • Takamura, K.1    Hayashi, K.2    Ishinishi, N.3    Yamada, T.4    Sugioka, Y.5
  • 22
    • 84939677652 scopus 로고
    • Comparative cell culture effects of shape memory metal (nitinol®), nickel and titanium: A biocompatibility estimation
    • J. L. M. Putters, D. M. K. S. Kaulesar Sukul, G. R. de Zeeuw, A. Bijma, and P. A. Besselink, "Comparative cell culture effects of shape memory metal (nitinol®), nickel and titanium: A biocompatibility estimation," Eur. Surg. Res., 24, 378-382 (1992).
    • (1992) Eur. Surg. Res. , vol.24 , pp. 378-382
    • Putters, J.L.M.1    Kaulesar Sukul, D.M.K.S.2    De Zeeuw, G.R.3    Bijma, A.4    Besselink, P.A.5
  • 26
    • 77957175234 scopus 로고
    • Carcinogenicity of metal alloys in orthopedic prostheses: Clinical and experimental studies
    • F. W. Sunderman, "Carcinogenicity of metal alloys in orthopedic prostheses: Clinical and experimental studies," Fundam. Appl. Toxicol., 13, 205-216 (1989).
    • (1989) Fundam. Appl. Toxicol. , vol.13 , pp. 205-216
    • Sunderman, F.W.1
  • 27
    • 0026684913 scopus 로고
    • Metal carcinogenesis: Mechanistic implications
    • E. Snow, "Metal carcinogenesis: Mechanistic implications," Pharmacol. Ther., 53, 31-65 (1992).
    • (1992) Pharmacol. Ther. , vol.53 , pp. 31-65
    • Snow, E.1
  • 28
  • 29
    • 0027638758 scopus 로고
    • In vitro immuno-cytotoxicity of iron evaluated by DNA synthesis of human T lymphocytes stimulated via CD2 and CD3
    • G. S. Carvalho and I. Bravo, "In vitro immuno-cytotoxicity of iron evaluated by DNA synthesis of human T lymphocytes stimulated via CD2 and CD3," J. Mater. Sci. Mater. Med., 4, 366-371 (1993).
    • (1993) J. Mater. Sci. Mater. Med. , vol.4 , pp. 366-371
    • Carvalho, G.S.1    Bravo, I.2
  • 31
    • 2642582913 scopus 로고    scopus 로고
    • Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures
    • J. Ryhanen, E. Niemi, W. Serlo, E. Niemela, P. Sandvik, H. Pernu, and T. Salo, "Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures," J. Biomed. Mater. Res., 35, 451-457 (1997).
    • (1997) J. Biomed. Mater. Res. , vol.35 , pp. 451-457
    • Ryhanen, J.1    Niemi, E.2    Serlo, W.3    Niemela, E.4    Sandvik, P.5    Pernu, H.6    Salo, T.7
  • 33
    • 0030332536 scopus 로고    scopus 로고
    • Corrosion resistance improvement of NiTi osteosynthesis staples by plasma polymerized tetrafluoroethylene coating
    • F. Villermaux, M. Tabrizian, L. H. Yahia, G. Czeremuszkin, and D. Piron, "Corrosion resistance improvement of NiTi osteosynthesis staples by plasma polymerized tetrafluoroethylene coating," Biomed. Mater. Eng., 6, 241-254 (1996).
    • (1996) Biomed. Mater. Eng. , vol.6 , pp. 241-254
    • Villermaux, F.1    Tabrizian, M.2    Yahia, L.H.3    Czeremuszkin, G.4    Piron, D.5
  • 34
    • 0030270078 scopus 로고    scopus 로고
    • Biocompatibility testing of NiTi screws using immunohistochemistry on sections containing metallic implants
    • M. Berger-Gorbet, B. Broxup, C. H. Rivard, and L. H. Yahia, "Biocompatibility testing of NiTi screws using immunohistochemistry on sections containing metallic implants," J. Biomed. Mater. Res., 32, 243-248 (1996).
    • (1996) J. Biomed. Mater. Res. , vol.32 , pp. 243-248
    • Berger-Gorbet, M.1    Broxup, B.2    Rivard, C.H.3    Yahia, L.H.4
  • 35
    • 7144256063 scopus 로고    scopus 로고
    • Unpublished data
    • L. H. Yahia, Unpublished data.
    • Yahia, L.H.1
  • 36
    • 0031033349 scopus 로고    scopus 로고
    • Histomorphometric analysis of the response of rat tibiae to shape memory alloy (nitinol)
    • F. Takeshita, H. Takata, Y. Ayukawa, and T. Suetsugu, "Histomorphometric analysis of the response of rat tibiae to shape memory alloy (nitinol)," Biomaterials, 18, 21-25 (1997).
    • (1997) Biomaterials , vol.18 , pp. 21-25
    • Takeshita, F.1    Takata, H.2    Ayukawa, Y.3    Suetsugu, T.4
  • 40
    • 0029278135 scopus 로고
    • Cranial bone apposition and ingrowth in a porous nickel-titanium implant
    • S. J. Simske and R. Sachdeva, "Cranial bone apposition and ingrowth in a porous nickel-titanium implant," J. Biomed. Mater. Res., 29, 527-533 (1995).
    • (1995) J. Biomed. Mater. Res. , vol.29 , pp. 527-533
    • Simske, S.J.1    Sachdeva, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.