메뉴 건너뛰기




Volumn 16, Issue 7, 1998, Pages 1220-1227

Reproducible optical fiber tips for photon scanning tunneling microscopy with very small (<5°) cone angle

Author keywords

Chemical etching; Mutlimode optical fibers; Near field microscopy; Optical fiber tips; Photon scanning tunneling microscopy (PSTM)

Indexed keywords

ATOMIC FORCE MICROSCOPY; ETCHING; LIGHT REFLECTION; PHOTONS; SCANNING TUNNELING MICROSCOPY;

EID: 0032123736     PISSN: 07338724     EISSN: None     Source Type: Journal    
DOI: 10.1109/50.701400     Document Type: Article
Times cited : (18)

References (12)
  • 1
    • 0012618901 scopus 로고
    • The atomic force microscope
    • G. Binnig, C. Quate, and C. Gerber, "The atomic force microscope," Phys. Rev. Lett., vol. 56, pp. 930-934, 1986.
    • (1986) Phys. Rev. Lett. , vol.56 , pp. 930-934
    • Binnig, G.1    Quate, C.2    Gerber, C.3
  • 3
    • 34848919386 scopus 로고
    • Review articles
    • G. Binnig, H. Rohrer, C. Gerber, and E. Weibel, Phys. Rev. Lett., vol. 49, p. 57, 1982; see also, G. Binnig and H. Rohrer, "Review articles," Physica, vol. 37, 1984.
    • (1984) Physica , vol.37
    • Binnig, G.1    Rohrer, H.2
  • 4
    • 0000853320 scopus 로고
    • New form of scanning optical microscopy
    • R. C. Reddick, R. J. Warmack, and T. L. Ferrell, "New form of scanning optical microscopy," Phys. Rev. B. vol. 39, pp. 767-770, 1989.
    • (1989) Phys. Rev. B. , vol.39 , pp. 767-770
    • Reddick, R.C.1    Warmack, R.J.2    Ferrell, T.L.3
  • 5
    • 0347279376 scopus 로고
    • An evanescent field optical microscope
    • Optical Storage and Scanning Technology, T. Wilson, Ed.
    • F. de Fornel, J. P. Goudonnet, L. Salomon, and E. Lesniewska, "An evanescent field optical microscope," in Optical Storage and Scanning Technology, T. Wilson, Ed. Proc. Soc. Photo-opt. Instrum. Eng., 1989, vol. 1139, pp. 77-84.
    • (1989) Proc. Soc. Photo-opt. Instrum. Eng. , vol.1139 , pp. 77-84
    • De Fornel, F.1    Goudonnet, J.P.2    Salomon, L.3    Lesniewska, E.4
  • 6
    • 84975562540 scopus 로고
    • General principles of scanning tunneling optical microscopy
    • J. M. Vigoureux, C. Girard, and D. Courjon, "General principles of scanning tunneling optical microscopy," Opt. Lett., vol. 14, pp. 1039-1041, 1989.
    • (1989) Opt. Lett. , vol.14 , pp. 1039-1041
    • Vigoureux, J.M.1    Girard, C.2    Courjon, D.3
  • 7
    • 0029342175 scopus 로고
    • Progress of high resolution photon scanning tunneling microscopy due to a nanometric fiber probe
    • July
    • M. Ohtsu, "Progress of high resolution photon scanning tunneling microscopy due to a nanometric fiber probe," J. Lightwave Technol., vol. 13, pp. 1200-1221, July 1995.
    • (1995) J. Lightwave Technol. , vol.13 , pp. 1200-1221
    • Ohtsu, M.1
  • 8
    • 0026897521 scopus 로고
    • Nanometric scale biosample observation using a photon scanning tunneling microscope
    • S. Jiang, H. Ohsawa, K. Yamada, T. Pangaribuan, M. Ohtsu, K. Imai, and A. Ikai, "Nanometric scale biosample observation using a photon scanning tunneling microscope," Japan J. Appl. Phys., vol. 31, pt. 1, no. 7, pp. 2282-2287, 1992.
    • (1992) Japan J. Appl. Phys. , vol.31 , Issue.7 PART 1 , pp. 2282-2287
    • Jiang, S.1    Ohsawa, H.2    Yamada, K.3    Pangaribuan, T.4    Ohtsu, M.5    Imai, K.6    Ikai, A.7
  • 9
    • 0029520939 scopus 로고
    • Control of apex shape of the fiber probe employed in photon scanning tunneling microscope by a multistep etcing method
    • Dec.
    • R. U. Maheswari, S. Mononode, and M. Ohtsu, "Control of apex shape of the fiber probe employed in photon scanning tunneling microscope by a multistep etcing method," J. Lightwave Technol., vol. 13, pp. 2308-2313, Dec. 1995.
    • (1995) J. Lightwave Technol. , vol.13 , pp. 2308-2313
    • Maheswari, R.U.1    Mononode, S.2    Ohtsu, M.3
  • 10
    • 0029185074 scopus 로고
    • High spatial resolution diagnostics using photon scanning tunneling microscope
    • Jan.
    • Y. Toda and M. Ohtsu, "High spatial resolution diagnostics using photon scanning tunneling microscope," IEEE Photon. Technol. Lett., vol. 7, pp. 84-86, Jan. 1995.
    • (1995) IEEE Photon. Technol. Lett. , vol.7 , pp. 84-86
    • Toda, Y.1    Ohtsu, M.2
  • 11
    • 0026918550 scopus 로고
    • Reproducible fabrication technique of nanometric tip diameter fiber probe for photon scanning tunneling microscope
    • A
    • T. Pangaribuan, K. Yamada, S. Jiang, H. Ohsawa, and M. Ohtsu, "Reproducible fabrication technique of nanometric tip diameter fiber probe for photon scanning tunneling microscope," Japan J. Appl. Phys., vol. 31, pt. 2, no. 9A, pp. L1302-L1304, 1992.
    • (1992) Japan J. Appl. Phys. , vol.31 , Issue.9 PART 2
    • Pangaribuan, T.1    Yamada, K.2    Jiang, S.3    Ohsawa, H.4    Ohtsu, M.5
  • 12
    • 0007190661 scopus 로고
    • Preparation of low loss optical fibers using simultaneous vapor phase deposition and fusion
    • J. B. MacChesney, P. B. O'Connor, F. V. DiMarcello, and P. D. Lazdy, "Preparation of low loss optical fibers using simultaneous vapor phase deposition and fusion," in Proc. Int. Congr. Glass, 1974, vol. 6, pp. 40-45.
    • (1974) Proc. Int. Congr. Glass , vol.6 , pp. 40-45
    • MacChesney, J.B.1    O'Connor, P.B.2    DiMarcello, F.V.3    Lazdy, P.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.