메뉴 건너뛰기




Volumn 13, Issue 3, 1998, Pages 783-790

The effect of neutral earthing practices on lightning current dispersion in a low-voltage installation

Author keywords

[No Author keywords available]

Indexed keywords

CODES (STANDARDS); COMPUTER SIMULATION; ELECTROMAGNETIC DISPERSION; LIGHTNING; SURGE PROTECTION;

EID: 0032121507     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/61.686975     Document Type: Article
Times cited : (15)

References (20)
  • 1
    • 33747266943 scopus 로고
    • Electromagnetic Transient Program (EMTP), Version 2.0; Volume 1: Main Program: Volume 2: Auxiliary Routines
    • July
    • EPRI, "Electromagnetic Transient Program (EMTP), Version 2.0; Volume 1: Main Program: Volume 2: Auxiliary Routines, EPRI Report EL-6421-L, July 1989.
    • (1989) EPRI Report EL-6421-L
  • 5
    • 84888925472 scopus 로고    scopus 로고
    • Driving High Surge Currents into Long Cables: More Begets Less
    • IEEE PES Summer Meeting, Denver CO
    • Mansoor, A. and Martzloff, F.D., "Driving High Surge Currents into Long Cables: More Begets Less," Paper 96 SM399-6 PWRD, IEEE PES Summer Meeting, Denver CO, 1996.
    • (1996) Paper 96 SM399-6 PWRD
    • Mansoor, A.1    Martzloff, F.D.2
  • 7
    • 0027624005 scopus 로고
    • Coordinating Cascaded Surge Protection Devices: High-Low versus Low-High
    • July/August
    • Lai, J.S. and Martzloff, F.D., "Coordinating Cascaded Surge Protection Devices: High-Low versus Low-High," IEEE Transactions IA-29 No.4, July/August 1993, pp 680-687.
    • (1993) IEEE Transactions IA-29 , Issue.4 , pp. 680-687
    • Lai, J.S.1    Martzloff, F.D.2
  • 8
    • 6244249228 scopus 로고
    • Systemgerechter Einsatz von Ableitern in Niederspannungsnetzen
    • Birkl, J., Hasse, P., and Zahlmann, P., "Systemgerechter Einsatz von Ableitern in Niederspannungsnetzen," Elektrotechnische Zeitschrift No.17, 1994, pp 964-971
    • (1994) Elektrotechnische Zeitschrift , Issue.17 , pp. 964-971
    • Birkl, J.1    Hasse, P.2    Zahlmann, P.3
  • 9
    • 33747509498 scopus 로고    scopus 로고
    • Efficiency of Lightning Protection System as Screening Measure Against LEMP
    • September
    • Flisowski, Z., and Mazzetti, C., "Efficiency of Lightning Protection System as Screening Measure Against LEMP," Proceedings, EMC'96 ROMA, September 1996.
    • (1996) Proceedings, EMC'96 ROMA
    • Flisowski, Z.1    Mazzetti, C.2
  • 11
    • 0028892060 scopus 로고
    • Cloud-to-Ground Lightning Mechanisms of Damage and Methods of Protection
    • September
    • Kirder, E.P. and Uman, M.A., "Cloud-to-Ground Lightning Mechanisms of Damage and Methods of Protection," Seminars in Neurology, Vol. 15, No.3, September 1995.
    • (1995) Seminars in Neurology , vol.15 , Issue.3
    • Kirder, E.P.1    Uman, M.A.2
  • 12
    • 0022915233 scopus 로고
    • Low-Voltage-Side Current-Surge Phenomena in a Single-Phase Distribution Transformer System
    • April
    • Dugan, R.C. and Smith, S.D., "Low-Voltage-Side Current-Surge Phenomena in a Single-Phase Distribution Transformer System," IEEE Transactions PWRD-13, No. 2, April 1988.
    • (1988) IEEE Transactions PWRD-13 , Issue.2
    • Dugan, R.C.1    Smith, S.D.2
  • 13
    • 33747511028 scopus 로고
    • Investigation of a Family of Power Conditioners Integrated into the Utility Grid
    • Steigerwald, R.L., Ferraro, A., and Tompkins, R.E, "Investigation of a Family of Power Conditioners Integrated into the Utility Grid," Sandia Report SAND81-7031, 1981, page 20.
    • (1981) Sandia Report SAND81-7031 , pp. 20
    • Steigerwald, R.L.1    Ferraro, A.2    Tompkins, R.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.