Volumn 145, Issue 4, 1998, Pages 141-146

Impulse breakdown of short rod-plane gaps and the influence of humidity

Author keywords

50 breakdown voltages; Humidity correction factors; Impulse voltages; Rod plane gaps

Indexed keywords

ATMOSPHERIC HUMIDITY; ELECTRIC BREAKDOWN; ELECTRIC CORONA; STATISTICAL METHODS;

EID: 0032120542     PISSN: 13502344     EISSN: None     Source Type: Journal    
DOI: 10.1049/ip-smt:19982106     Document Type: Article
Times cited : (10)

References (12)
  • 2
    • 0017016983 scopus 로고
    • Particularities of air insulation behaviour
    • MENEMENLIS, C., and HARBEC, G.: 'Particularities of air insulation behaviour'. IEEE Trans., 1976, PAS-95, (6), pp. 1814-1821
    • (1976) IEEE Trans. , vol.PAS-95 , Issue.6 , pp. 1814-1821
    • Menemenlis, C.1    Harbec, G.2
  • 5
    • 0022135113 scopus 로고
    • Influence of air density on the impulse strength of external insulation
    • PIGINI, A., SARTORIO, G., MORENO, M., RAMIREZ, M., CORTINA, R., and GARBAGNATI, E.: 'Influence of air density on the impulse strength of external insulation', IEEE Trans., 1985, PAS-104, (10), pp. 2888-2900
    • (1985) IEEE Trans. , vol.PAS-104 , Issue.10 , pp. 2888-2900
    • Pigini, A.1    Sartorio, G.2    Moreno, M.3    Ramirez, M.4    Cortina, R.5    Garbagnati, E.6
  • 6
    • 33746155252 scopus 로고
    • Influence of humidity on the breakdown mechanism of small rod-plane gaps stressed by positive impulse voltages
    • STASSINOPOULOS, C.A., ANDREADOU, K., and SERGAKI, A.: 'Influence of humidity on the breakdown mechanism of small rod-plane gaps stressed by positive impulse voltages', etz Archiv, 1990, 12, pp. 273-277
    • (1990) Etz Archiv , vol.12 , pp. 273-277
    • Stassinopoulos, C.A.1    Andreadou, K.2    Sergaki, A.3
  • 8
    • 33645660741 scopus 로고
    • The breakdown voltage of air in a 50cm rod-plane gap over a practical range of air density and humidity
    • Braunschweig, paper 14.02
    • GELDENHUYS, H.J.: 'The breakdown voltage of air in a 50cm rod-plane gap over a practical range of air density and humidity.' Proceedings of 5th international symposium on High voltage engineering. Braunschweig, 1987, paper 14.02
    • (1987) Proceedings of 5th International Symposium on High Voltage Engineering
    • Geldenhuys, H.J.1
  • 9
    • 32144431540 scopus 로고
    • Corona, breakdown and humidity in the rod-plane gap
    • ALLEN, N.L.: 'Corona, breakdown and humidity in the rod-plane gap', IEE Proc. A, 1986, 133, (8), pp. 562-568
    • (1986) IEE Proc. A , vol.133 , Issue.8 , pp. 562-568
    • Allen, N.L.1
  • 11
    • 0028496535 scopus 로고
    • Influence of humidity on the breakdown mechanism of medium length rod-plane gaps stressed by positive impulse voltages
    • MIKROPOULOS, P.N., and STASSINOFOULOS, C.A.: 'Influence of humidity on the breakdown mechanism of medium length rod-plane gaps stressed by positive impulse voltages', IEE Proc. Sci. Meas. Technol., 1994, 141, (5), pp 407-417
    • (1994) IEE Proc. Sci. Meas. Technol. , vol.141 , Issue.5 , pp. 407-417
    • Mikropoulos, P.N.1    Stassinofoulos, C.A.2
  • 12
    • 0016983080 scopus 로고
    • Humidity influence on switching impulse breakdown of a 50 cm rod-plane gap
    • HAHN, G., ZACKE, P., FISHER, A., and BOECKER, H.: Humidity influence on switching impulse breakdown of a 50 cm rod-plane gap', IEEE Trans., 1978, PAS-95, (4), pp. 1145-1152
    • (1978) IEEE Trans. , vol.PAS-95 , Issue.4 , pp. 1145-1152
    • Hahn, G.1    Zacke, P.2    Fisher, A.3    Boecker, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.