Miniaturized implantable rotary blood pump in atrial-aortic position supports and unloads the failing heart

Author keywords

assist device; heart failure; rotary blood pump

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; BLOOD PUMP; HEART FAILURE; HEART HEMODYNAMICS; HEART OUTPUT; HEART PERFUSION; NONHUMAN; PRIORITY JOURNAL; SHEEP;

EID: 0032103766     PISSN: 17085381     EISSN: None     Source Type: Journal    
DOI: 10.1177/096721099800600312     Document Type: Article
Times cited : (22)

References (10)
  • 2
    • 0029149789 scopus 로고
    • Left ventricular assistance with the transthoracic 24F Hemopump for recovery of the failing heart
    • Meyns B. P., Sergeant P. T., Daenen W. J., Flameng W. J., Left ventricular assistance with the transthoracic 24F Hemopump for recovery of the failing heart. Annals of Thoracic Surgery, 1995, 60, 392–397.
    • (1995) Annals of Thoracic Surgery , vol.60 , pp. 392-397
    • Meyns, B.P.1    Sergeant, P.T.2    Daenen, W.J.3    Flameng, W.J.4
  • 3
    • 0029033127 scopus 로고
    • Combined registry for the clinical use of mechanical ventricular assist pumps and the total artificial heart in conjunction with heart transplantation: Sixth official report 1994
    • Mehta S. M., Aufiero T. X., Pae W. E., et al, Combined registry for the clinical use of mechanical ventricular assist pumps and the total artificial heart in conjunction with heart transplantation: Sixth official report 1994. Journal of Heart and Lung Transplants, 1995, 14, 585–593.
    • (1995) Journal of Heart and Lung Transplants , vol.14 , pp. 585-593
    • Mehta, S.M.1    Aufiero, T.X.2    Pae, W.E.3
  • 4
    • 0028152833 scopus 로고
    • Potential of left ventricular assist devices as outpatient therapy while awaiting transplantation
    • Levin H. R., Chen J. M., Oz M. C., et al, Potential of left ventricular assist devices as outpatient therapy while awaiting transplantation. Annals of Thoracic Surgery, 1994, 58, 1515–1520.
    • (1994) Annals of Thoracic Surgery , vol.58 , pp. 1515-1520
    • Levin, H.R.1    Chen, J.M.2    Oz, M.C.3
  • 6
    • 0010523126 scopus 로고
    • Simultaneous reduction in anti-B1 adrenoceptor autoantibodies and cardiac functional improvement during mechanical support: Implication for weaning from assist device?
    • Mueller J., Wallukat G., Weng Y., et al, Simultaneous reduction in anti-B1 adrenoceptor autoantibodies and cardiac functional improvement during mechanical support: Implication for weaning from assist device? International Journal of Artificial Organs, 1995, 18, 453.
    • (1995) International Journal of Artificial Organs , vol.18 , pp. 453
    • Mueller, J.1    Wallukat, G.2    Weng, Y.3
  • 8
    • 0028353650 scopus 로고
    • Technical requirements and limitations of miniaturised axial flow pumps for circulatory support
    • Reul H., Technical requirements and limitations of miniaturised axial flow pumps for circulatory support. Cardiology, 1994, 84, 187–193.
    • (1994) Cardiology , vol.84 , pp. 187-193
    • Reul, H.1
  • 9
    • 0010488718 scopus 로고
    • The heart-Hemopump interaction: in vivo study of axial pump flow performance
    • Meyns B., Siess T., Reul H., et al, The heart-Hemopump interaction: in vivo study of axial pump flow performance. International Journal of Artificial Organs, 1995, 18, 452.
    • (1995) International Journal of Artificial Organs , vol.18 , pp. 452
    • Meyns, B.1    Siess, T.2    Reul, H.3
  • 10
    • 0030017832 scopus 로고    scopus 로고
    • Hemodynamic system-analysis of intraarterial microaxial pumps in vitro and in vivo
    • Siess T., Meyns B., Spielvogel K., et al, Hemodynamic system-analysis of intraarterial microaxial pumps in vitro and in vivo. Artificial Organs, 1996, 20, 650–661.
    • (1996) Artificial Organs , vol.20 , pp. 650-661
    • Siess, T.1    Meyns, B.2    Spielvogel, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.