메뉴 건너뛰기




Volumn 120, Issue 3, 1998, Pages 327-333

An implantable transducer for measuring tension in an anterior cruciate ligament graft

Author keywords

[No Author keywords available]

Indexed keywords

BIOMECHANICS; CALIBRATION; FORCE MEASUREMENT; FRACTURE FIXATION; GRAFTS; LIGAMENTS; SURGERY; TRANSDUCERS;

EID: 0032101856     PISSN: 01480731     EISSN: 15288951     Source Type: Journal    
DOI: 10.1115/1.2797998     Document Type: Article
Times cited : (7)

References (25)
  • 1
    • 0029394761 scopus 로고
    • A new load application system for in vitro study of ligamentous injuries to the human knee joint
    • Bach, J. M., and Hull, M. L., “A new load application system for in vitro study of ligamentous injuries to the human knee joint,” ASME Journal of Biomechanical Engineering, 117:373-382, 1995.
    • (1995) ASME Journal of Biomechanical Engineering , vol.117 , pp. 373-382
    • Bach, J.M.1    Hull, M.L.2
  • 2
    • 0024691806 scopus 로고
    • Use of patellar tendon autograft for anterior cruciate ligament reconstruction in the rabbit: A long-term histologic and biomechanical study
    • Ballock, R. T., Woo, S. L.-Y., Lyon, R. M., Hollis, J. M., Akeson, W. H., “Use of patellar tendon autograft for anterior cruciate ligament reconstruction in the rabbit: A long-term histologic and biomechanical study,” J. Orthop. Res., 7:474-485, 1989.
    • (1989) J. Orthop. Res , vol.7 , pp. 474-485
    • Ballock, R.T.1    Woo, S.L.2    Lyon, R.M.3    Hollis, J.M.4    Akeson, W.H.5
  • 3
    • 0022708543 scopus 로고
    • Design and performance of a modified buckle transducer for the measurement of ligament tension
    • Barry, D., and Ahmed, A. M., “Design and performance of a modified buckle transducer for the measurement of ligament tension,” ASME Journal of Biomechanical Engineering, 108:149-152, 1986.
    • (1986) ASME Journal of Biomechanical Engineering , vol.108 , pp. 149-152
    • Barry, D.1    Ahmed, A.M.2
  • 4
    • 0025644369 scopus 로고
    • Implementation of a five degree of freedom automated system to determine knee flexibility in vitro
    • Berns, G. S., Hull, M. L., Patterson, H. A., “Implementation of a five degree of freedom automated system to determine knee flexibility in vitro,” ASME Journal of Biomechanical Engineering, 112:392-400, 1990.
    • (1990) ASME Journal of Biomechanical Engineering , vol.112 , pp. 392-400
    • Berns, G.S.1    Hull, M.L.2    Patterson, H.A.3
  • 6
    • 0024585607 scopus 로고
    • Mechanical properties of primate vascularized vs. Nonvascularized patellar tendon grafts; Changes over time
    • Butler, D. L., Grood, E. S., Noyes, F. R., Olmstead, M. L., Hohn, R. B., Arnoc-zky, S. P., Siegel, M. G., “Mechanical properties of primate vascularized vs. nonvascularized patellar tendon grafts; Changes over time,” J. Orthop. Res., 7:68-79, 1989.
    • (1989) J. Orthop. Res , vol.7 , pp. 68-79
    • Butler, D.L.1    Grood, E.S.2    Noyes, F.R.3    Olmstead, M.L.4    Hohn, R.B.5    Arnoc-Zky, S.P.6    Siegel, M.G.7
  • 7
    • 0026625326 scopus 로고
    • Accuracy of clinical isometry and preload testing during anterior cruciate ligament reconstruction
    • Flandry, F., Terry, G. C., Montgomery, R. D., Kester, M. A., Madsen, N., “Accuracy of clinical isometry and preload testing during anterior cruciate ligament reconstruction,” Clin. Orthop., 279:214-222, 1992.
    • (1992) Clin. Orthop , vol.279 , pp. 214-222
    • Flandry, F.1    Terry, G.C.2    Montgomery, R.D.3    Kester, M.A.4    Madsen, N.5
  • 8
    • 0039330460 scopus 로고    scopus 로고
    • Measurement of anterior cruciate ligament (ACL) graft loads using an arthroscopic implantable force probe
    • Fleming, B. C., Good, L., Peura, G. D., Beynnon, B.D., “Measurement of anterior cruciate ligament (ACL) graft loads using an arthroscopic implantable force probe,” Trans, of the 42nd Annual Meeting of ORS, 21:75, 1996.
    • (1996) Trans, of the 42Nd Annual Meeting of ORS , vol.21 , pp. 75
    • Fleming, B.C.1    Good, L.2    Peura, G.D.3    Beynnon, B.D.4
  • 9
    • 0027703506 scopus 로고
    • In vitro evaluation of an implantable force transducer (IFP) in a patellar tendon model
    • Glos, D. L., Butler, D. L., Grood, E. S., Levy, M. S., “In vitro evaluation of an implantable force transducer (IFP) in a patellar tendon model,” ASME Journal of Biomechanical Engineering, 115:335-342, 1993.
    • (1993) ASME Journal of Biomechanical Engineering , vol.115 , pp. 335-342
    • Glos, D.L.1    Butler, D.L.2    Grood, E.S.3    Levy, M.S.4
  • 10
    • 0031106369 scopus 로고    scopus 로고
    • Injury mechanisms in anterior cruciate ligament grafts from intercondylar roof impingement during passive knee extension
    • Goss, B. C., Hull, M. L., Howell, S. M., “Injury mechanisms in anterior cruciate ligament grafts from intercondylar roof impingement during passive knee extension,” J. Orthop. Res., 15:263-268, 1997.
    • (1997) J. Orthop. Res , vol.15 , pp. 263-268
    • Goss, B.C.1    Hull, M.L.2    Howell, S.M.3
  • 11
    • 0002883851 scopus 로고
    • Isometric placement of substitutes for the anterior cruciate ligament
    • D. W. Jackson and D. Drez, Jr., eds., St. Louis, CV Mosby
    • Graf, B., “Isometric placement of substitutes for the anterior cruciate ligament,” in: The Anterior Cruciate Deficient Knee: New Concepts in Ligament Repair, D. W. Jackson and D. Drez, Jr., eds., St. Louis, CV Mosby, 1987, pp. 102-113.
    • (1987) The Anterior Cruciate Deficient Knee: New Concepts in Ligament Repair , pp. 102-113
    • Graf, B.1
  • 12
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of three dimensional motions: Application to the knee
    • Grood, E. S., and Suntay, W. J., “A joint coordinate system for the clinical description of three dimensional motions: application to the knee,” ASME Journal of Biomechanical Engineering, 105:136-144, 1983.
    • (1983) ASME Journal of Biomechanical Engineering , vol.105 , pp. 136-144
    • Grood, E.S.1    Suntay, W.J.2
  • 13
    • 0030032281 scopus 로고    scopus 로고
    • Evaluation of the implantable force transducer for chronic tendon-force recordings
    • Herzog, W., Archambault, J. M., Leonard, T. R., Nguyen, H. K., “Evaluation of the implantable force transducer for chronic tendon-force recordings,” J. Bio-mech., 29:103-109, 1996.
    • (1996) J. Bio-Mech , vol.29 , pp. 103-109
    • Herzog, W.1    Archambault, J.M.2    Leonard, T.R.3    Nguyen, H.K.4
  • 14
    • 0028434083 scopus 로고
    • In vivo forces in the anterior cruciate ligament: Direct measurements during walking and trotting in a quadruped
    • Holden, J. P., Grood, E. S., Korvick, D. L., Cummings, J. F., Butler, D. L., Bylski-Austrow, D. I., “In vivo forces in the anterior cruciate ligament: Direct measurements during walking and trotting in a quadruped,” J. Biomech., 27:517-526, 1994.
    • (1994) J. Biomech , vol.27 , pp. 517-526
    • Holden, J.P.1    Grood, E.S.2    Korvick, D.L.3    Cummings, J.F.4    Butler, D.L.5    Bylski-Austrow, D.I.6
  • 15
    • 0028958365 scopus 로고
    • Factors affecting sensitivity of a transducer for measuring anterior cruciate ligament force
    • Holden, J. P., Grood, E. S., Cummings, J. F., “Factors affecting sensitivity of a transducer for measuring anterior cruciate ligament force,” J. Biomech., 28:99102, 1995.
    • (1995) J. Biomech , vol.28 , pp. 99102
    • Holden, J.P.1    Grood, E.S.2    Cummings, J.F.3
  • 16
    • 0002217715 scopus 로고
    • Arthroscopically assisted technique for preventing roof impingement of an anterior cruciate ligament graft illustrated by the use of an autogenous double-looped semitendinosus and gracilis graft
    • Howell, S. M., “Arthroscopically assisted technique for preventing roof impingement of an anterior cruciate ligament graft illustrated by the use of an autogenous double-looped semitendinosus and gracilis graft,” Oper. Tech. Sports Med., 1:58-65, 1993.
    • (1993) Oper. Tech. Sports Med , vol.1 , pp. 58-65
    • Howell, S.M.1
  • 17
    • 0000271648 scopus 로고    scopus 로고
    • Endoscopic fixation of a double-looped semitendinosus and gracilis ACL graft using bone mulch screw
    • Howell, S. M., and Gottlieb, J., “Endoscopic fixation of a double-looped semitendinosus and gracilis ACL graft using bone mulch screw,” Oper. Tech. Orthop., 6:152-160, 1996.
    • (1996) Oper. Tech. Orthop , vol.6 , pp. 152-160
    • Howell, S.M.1    Gottlieb, J.2
  • 18
    • 0020134577 scopus 로고
    • A note on the application and evaluation of the buckle transducer for knee ligament force measurement
    • Lewis, J. L., Lew, W. D., Schmidt, J., “A note on the application and evaluation of the buckle transducer for knee ligament force measurement,” ASME Journal of Biomechanical Engineering, 104:125-128, 1982.
    • (1982) ASME Journal of Biomechanical Engineering , vol.104 , pp. 125-128
    • Lewis, J.L.1    Lew, W.D.2    Schmidt, J.3
  • 19
    • 0032077358 scopus 로고    scopus 로고
    • Telemetry system for monitoring anterior cruciate ligament graft forces in vivo
    • McKee, E. L., Lindsey, D., Hull, M. L., Howell, S. M., “Telemetry system for monitoring anterior cruciate ligament graft forces in vivo,” to appear in Med. Biol. Eng. Comp., 1998.
    • (1998) Med. Biol. Eng. Comp
    • McKee, E.L.1    Lindsey, D.2    Hull, M.L.3    Howell, S.M.4
  • 21
    • 0027733655 scopus 로고
    • Tendon healing in a bone tunnel: A biomechanical and histological study in the dog
    • Rodeo, S. A., Arnoczky, S. P., Torzilli, P. A., Hidaka, C., Warren, R. F., “Tendon healing in a bone tunnel: a biomechanical and histological study in the dog,” J. Bone Joint. Surg., 75A: 1795-1803, 1993.
    • (1993) J. Bone Joint. Surg , vol.75A , pp. 1795-1803
    • Rodeo, S.A.1    Arnoczky, S.P.2    Torzilli, P.A.3    Hidaka, C.4    Warren, R.F.5
  • 22
    • 0343413299 scopus 로고
    • Evaluation of the arthroscopic force probe; a study of the factors that effect the measurement of tendon and ligament force in-vivo
    • Tohyama, H., Beynnon, B. D., Fleming, B. C., Peura, G. C., Johnson, R.J., Pope, M. H., “Evaluation of the arthroscopic force probe; a study of the factors that effect the measurement of tendon and ligament force in-vivo,” Trans, of 40th Annual Meeting of ORS, 19:644, 1994.
    • (1994) Trans, of 40Th Annual Meeting of ORS , vol.19 , pp. 644
    • Tohyama, H.1    Beynnon, B.D.2    Fleming, B.C.3    Peura, G.C.4    Johnson, R.J.5    Pope, M.H.6
  • 23
    • 0031194073 scopus 로고    scopus 로고
    • In vivo tensile behavior of a four-bundled hamstrings graft as a replacement for the anterior cruciate ligament
    • Wallace, M., Howell, S. M., Hull, M. L., “In vivo tensile behavior of a four-bundled hamstrings graft as a replacement for the anterior cruciate ligament,” J. Orthop. Res., 15: 539-545, 1997.
    • (1997) J. Orthop. Res , vol.15 , pp. 539-545
    • Wallace, M.1    Howell, S.M.2    Hull, M.L.3
  • 24
    • 0024553038 scopus 로고
    • Analysis of rehabilitation techniques after anterior cruciate reconstruction
    • Anderson, A. F., and Lipscomb, A. B., “Analysis of rehabilitation techniques after anterior cruciate reconstruction,” Am. J. Sports Med., 17:154-160, 1989.
    • (1989) Am. J. Sports Med , vol.17 , pp. 154-160
    • Anderson, A.F.1    Lipscomb, A.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.