메뉴 건너뛰기




Volumn 24, Issue 5, 1998, Pages 631-637

Dynamic imaging of coronary stent structures: An ECG-gated three- dimensional intracoronary ultrasound study in humans

Author keywords

Computer assisted methods; Coronary vessels; Image processing; Intracoronary ultrasound; Stents; Ultrasonography

Indexed keywords

BLOOD VESSELS; COMPUTER AIDED DIAGNOSIS; ELECTROCARDIOGRAPHY; IMAGE RECONSTRUCTION; IMPLANTS (SURGICAL); MEDICAL IMAGING;

EID: 0032100689     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(98)00038-6     Document Type: Article
Times cited : (8)

References (18)
  • 1
    • 0027566388 scopus 로고
    • Resolution limitations in intravascular ultrasound imaging
    • P.J Benkeser A.L Churchwell C Lee Resolution limitations in intravascular ultrasound imaging J Am Soc Echocardiogr 6 1993 158 165
    • (1993) J Am Soc Echocardiogr , vol.6 , pp. 158-165
    • Benkeser, P.J1    Churchwell, A.L2    Lee, C3
  • 2
    • 0029518475 scopus 로고
    • Dynamic three-dimensional reconstruction of ICUS images based on an ecg-gated pull-back device
    • N Bruining C von Birgelen C Di Mario Dynamic three-dimensional reconstruction of ICUS images based on an ecg-gated pull-back device Computers in cardiology 1995 IEEE Computer Society Press Vienna 633 636
    • (1995) , pp. 633-636
    • Bruining, N1    von Birgelen, C2    Di Mario, C3
  • 3
    • 0030393155 scopus 로고    scopus 로고
    • ECG-gated ICUS image acquisition combined with a semi-automated contour detection provides accurate analysis of vessel dimensions
    • N Bruining C von Birgelen M.T Mallus ECG-gated ICUS image acquisition combined with a semi-automated contour detection provides accurate analysis of vessel dimensions Computers in cardiology 1996 IEEE Computer Society Press Indianapolis 53 56
    • (1996) , pp. 53-56
    • Bruining, N1    von Birgelen, C2    Mallus, M.T3
  • 4
    • 0026669023 scopus 로고
    • In vitro validation of three-dimensional intravascular ultrasound for the evaluation of arterial injury after balloon angioplasty
    • K.M Coy J.C Park M.C Fishbein In vitro validation of three-dimensional intravascular ultrasound for the evaluation of arterial injury after balloon angioplasty J Am Coll Cardiol 20 1992 692 700
    • (1992) J Am Coll Cardiol , vol.20 , pp. 692-700
    • Coy, K.M1    Park, J.C2    Fishbein, M.C3
  • 5
    • 0026643132 scopus 로고
    • Assessment of coronary stent by intravascular ultrasound
    • A.N Deaner A.A Cubukcu M.R Rees Assessment of coronary stent by intravascular ultrasound Int J Cardiol 36 1992 124 126
    • (1992) Int J Cardiol , vol.36 , pp. 124-126
    • Deaner, A.N1    Cubukcu, A.A2    Rees, M.R3
  • 6
    • 0029111978 scopus 로고
    • Small stent size and intimal hyperplasia contribute to restenosis: A volumetric intravascular ultrasound analysis
    • G.R Dussaillant G.S Mintz A.D Pichard Small stent size and intimal hyperplasia contribute to restenosis A volumetric intravascular ultrasound analysis J Am Coll Cardiol 26 1995 720 724
    • (1995) J Am Coll Cardiol , vol.26 , pp. 720-724
    • Dussaillant, G.R1    Mintz, G.S2    Pichard, A.D3
  • 7
    • 0026631097 scopus 로고
    • Intravascular ultrasound imaging of coronary arteries. Is three layers the norm?
    • P.J Fitzgerald F.G St. Goar A.J Connolly Intravascular ultrasound imaging of coronary arteries. Is three layers the norm? Circulation 86 1992 154 158
    • (1992) Circulation , vol.86 , pp. 154-158
    • Fitzgerald, P.J1    St. Goar, F.G2    Connolly, A.J3
  • 8
    • 0028017581 scopus 로고
    • Benefit of intracoronary ultrasound in the deployment of Palmaz-Schatz stents
    • S.L Goldberg A Colombo S Nakamura Benefit of intracoronary ultrasound in the deployment of Palmaz-Schatz stents J Am Coll Cardiol 24 1994 996 1003
    • (1994) J Am Coll Cardiol , vol.24 , pp. 996-1003
    • Goldberg, S.L1    Colombo, A2    Nakamura, S3
  • 9
    • 0029073780 scopus 로고
    • Atherosclerosis in angiographically “normal” coronary artery reference segments: An intravascular ultrasound study with clinical correlations
    • G.S Mintz J.A Painter A.D Pichard Atherosclerosis in angiographically “normal” coronary artery reference segments An intravascular ultrasound study with clinical correlations J Am Coll Cardiol 25 1995 1479 1485
    • (1995) J Am Coll Cardiol , vol.25 , pp. 1479-1485
    • Mintz, G.S1    Painter, J.A2    Pichard, A.D3
  • 10
    • 0027488552 scopus 로고
    • Three-dimensional intravascular ultrasonography: Reconstruction of endovascular stents in vitro and in vivo
    • G.S Mintz A.D Pichard L.F Satler Three-dimensional intravascular ultrasonography Reconstruction of endovascular stents in vitro and in vivo J Clin Ultrasound 21 1993 609 615
    • (1993) J Clin Ultrasound , vol.21 , pp. 609-615
    • Mintz, G.S1    Pichard, A.D2    Satler, L.F3
  • 11
    • 0029871176 scopus 로고    scopus 로고
    • Usefulness of on-line three-dimensional reconstruction of intracoronary ultrasound for guidance of stent deployment
    • F Prati C Di Mario R Gil Usefulness of on-line three-dimensional reconstruction of intracoronary ultrasound for guidance of stent deployment Am J Cardiol 77 1996 455 461
    • (1996) Am J Cardiol , vol.77 , pp. 455-461
    • Prati, F1    Di Mario, C2    Gil, R3
  • 12
    • 0028105943 scopus 로고
    • Three-dimensional reconstruction of intracoronary ultrasound images. Rationale, approaches, problems, and directions
    • J.R Roelandt C Di Mario N.G Pandian Three-dimensional reconstruction of intracoronary ultrasound images. Rationale, approaches, problems, and directions Circulation 90 1994 1044 1055
    • (1994) Circulation , vol.90 , pp. 1044-1055
    • Roelandt, J.R1    Di Mario, C2    Pandian, N.G3
  • 13
    • 0026005798 scopus 로고
    • Three-dimensional reconstruction of human coronary and peripheral arteries from images recorded during two-dimensional intravascular ultrasound examination
    • K Rosenfield D.W Losordo K Ramaswamy Three-dimensional reconstruction of human coronary and peripheral arteries from images recorded during two-dimensional intravascular ultrasound examination Circulation 84 1991 1938 1956
    • (1991) Circulation , vol.84 , pp. 1938-1956
    • Rosenfield, K1    Losordo, D.W2    Ramaswamy, K3
  • 14
    • 0031002875 scopus 로고    scopus 로고
    • An evaluation of the potential and limitations of three-dimensional reconstructions from intracoronary ultrasound images
    • A.B Thrush D.E Bonnet M.R Elliot An evaluation of the potential and limitations of three-dimensional reconstructions from intracoronary ultrasound images Ultrasound Med Biol 23 1997 437 445
    • (1997) Ultrasound Med Biol , vol.23 , pp. 437-445
    • Thrush, A.B1    Bonnet, D.E2    Elliot, M.R3
  • 15
    • 0029095328 scopus 로고
    • Three-dimensional reconstruction of coronary arteries with intravascular ultrasound
    • C von Birgelen R Erbel C Di Mario Three-dimensional reconstruction of coronary arteries with intravascular ultrasound Herz 20 1995 277 289
    • (1995) Herz , vol.20 , pp. 277-289
    • von Birgelen, C1    Erbel, R2    Di Mario, C3
  • 16
    • 0029902667 scopus 로고    scopus 로고
    • Optimized expansion of the Wallstent compared with the Palmaz-Schatz stent: On-line observations with two- and three-dimensional intracoronary ultrasound after angiographic guidance
    • C von Birgelen R Gil P Ruygrok Optimized expansion of the Wallstent compared with the Palmaz-Schatz stent On-line observations with two- and three-dimensional intracoronary ultrasound after angiographic guidance Am Heart J 131 1996 1067 1075
    • (1996) Am Heart J , vol.131 , pp. 1067-1075
    • von Birgelen, C1    Gil, R2    Ruygrok, P3
  • 17
    • 17544396118 scopus 로고    scopus 로고
    • Electrocardiogram-gated intravascular ultrasound image acquisition after coronary stent deployment facilitates on-line three-dimensional reconstruction and automated lumen quantification
    • C von Birgelen G.S Mintz A Nicosia Electrocardiogram-gated intravascular ultrasound image acquisition after coronary stent deployment facilitates on-line three-dimensional reconstruction and automated lumen quantification J Am Coll Cardiol 30 1997 436 443
    • (1997) J Am Coll Cardiol , vol.30 , pp. 436-443
    • von Birgelen, C1    Mintz, G.S2    Nicosia, A3
  • 18
    • 0030671369 scopus 로고    scopus 로고
    • ECG-gated three-dimensional intravascular ultrasound: Feasibility and reproducibility of an automated analysis of coronary lumen and atherosclerotic plaque dimensions in humans
    • C von Birgelen E.A de Vrey G.S Mintz ECG-gated three-dimensional intravascular ultrasound Feasibility and reproducibility of an automated analysis of coronary lumen and atherosclerotic plaque dimensions in humans Circulation 96 1997 2944 2952
    • (1997) Circulation , vol.96 , pp. 2944-2952
    • von Birgelen, C1    de Vrey, E.A2    Mintz, G.S3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.