메뉴 건너뛰기




Volumn 45, Issue 3 PART 2, 1998, Pages 1200-1206

Investigation of approaches to reduce truncation of attenuation maps with simultaneous transmission and emission spect imaging1

Author keywords

[No Author keywords available]

Indexed keywords

CAMERAS; CARDIOLOGY; COMPUTER SIMULATION; IMAGE RECONSTRUCTION; NUCLEAR MEDICINE; OPTICAL COLLIMATORS;

EID: 0032096158     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/23.682003     Document Type: Article
Times cited : (5)

References (17)
  • 1
    • 0029564459 scopus 로고
    • Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Imaging of attenuation and methods of estimating attenuation maps, J. Nuc. Cardiology
    • M. A. King, B. M. W. Tsui and T.-S. Pan, Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Imaging of attenuation and methods of estimating attenuation maps, J. Nuc. Cardiology, vol. 2, pp. 513-524, Nov., 1995.
    • (1995) B. M. W. Tsui and T.-S. Pan , vol.2 , pp. 513-524
    • King, M.A.1
  • 2
    • 0029357147 scopus 로고
    • Reduction of truncation artifacts in fan beam transmission by using parallel beam emission data
    • T.-S Pan, M. A. King, B. C. Penney, N. Rajeevan, D.-S. Luo, J. A. Case, Reduction of truncation artifacts in fan beam transmission by using parallel beam emission data, IEEE Trans. Nuc. Sei. vol. 42, pp. 1310-1319, Aug., 1995.
    • (1995) IEEE Trans. Nuc. Sei. , vol.42 , pp. 1310-1319
    • Pan, T.-S.1    King, M.A.2    Penney, B.C.3    Rajeevan, N.4    Luo, D.-S.5    Case, J.A.6
  • 3
    • 0029017223 scopus 로고
    • Simultaneous transmission-emission Thallium-201 cardiac SPECT: Effect of attenuation correction on myocardial tracer distribution, J
    • E. F. Ficaro, J. A. Fessier, K. J. Ackermann, W. L. Rogers, J. R. Corbett and M. Schwaiger, Simultaneous transmission-emission Thallium-201 cardiac SPECT: Effect of attenuation correction on myocardial tracer distribution, J. Nue. Med., vol. 36, pp. 921-931, June, 1995.
    • (1995) Nue. Med. , vol.36 , pp. 921-931
    • Ficaro, E.F.1    Fessier, J.A.2    Ackermann, K.J.3    Rogers, W.L.4    Corbett, J.R.5    Schwaiger, M.6
  • 4
    • 33747251425 scopus 로고    scopus 로고
    • Assessment of triple head simultaneous Tc-transniission Tc-emission tomography (Tc-Tc STET), J
    • L. R. Barnden and C.C. Rowe, Assessment of triple head simultaneous Tc-transniission Tc-emission tomography (Tc-Tc STET), J. Nue. Med. vol. 38, pp. 218, May, 1997.
    • (1997) Nue. Med. , vol.38 , pp. 218
    • Barnden, L.R.1    Rowe, C.C.2
  • 5
    • 0030353813 scopus 로고    scopus 로고
    • Evaluation of the effects of patient arm attenuation in SPECT cardiac Perfusion imaging
    • D.-S. Luo, M. A. King, T.-S. Pan and W. Xia, Evaluation of the effects of patient arm attenuation in SPECT cardiac Perfusion imaging, IEEE Trans. Nuc. Sei. vol. 43, pp., 3291-3299, Dec., 1996.
    • (1996) IEEE Trans. Nuc. Sei. , vol.43 , pp. 3291-3299
    • Luo, D.-S.1    King, M.A.2    Pan, T.-S.3    Xia, W.4
  • 6
    • 0030214559 scopus 로고    scopus 로고
    • The effect of truncation reduction in fan beam transmission for attenuation correction of cardiac SPECT
    • R. J. Jaszczak, D. R. Gilland, J. W. McCormick, C. Scarfone, R. E. Coleman, The effect of truncation reduction in fan beam transmission for attenuation correction of cardiac SPECT, IEEE Trans. Nuc. Sei. vol. 43, pp. 2255-2262, Aug., 1996.
    • (1996) IEEE Trans. Nuc. Sei. , vol.43 , pp. 2255-2262
    • Jaszczak, R.J.1    Gilland, D.R.2    McCormick, J.W.3    Scarfone, C.4    Coleman, R.E.5
  • 8
    • 0000900582 scopus 로고    scopus 로고
    • Long focal length asymmetric fan beam collimation for transmission acquisition with a triple camera SPECT system
    • D. R. Gilland, H. Wang, R. E. Coleman and R. J. Jaszczak, Long focal length asymmetric fan beam collimation for transmission acquisition with a triple camera SPECT system, IEEE Trans. Nuc. Sei, vol. 44, pp. 1191-1196, June, 1997.
    • (1997) IEEE Trans. Nuc. Sei , vol.44 , pp. 1191-1196
    • Gilland, D.R.1    Wang, H.2    Coleman, R.E.3    Jaszczak, R.J.4
  • 9
    • 0030026377 scopus 로고    scopus 로고
    • M. A. King, D.-S. Luo, S. T. Dahlberg and B. J. Villegas, Transmission imaging of large attenuators using a slant hole collimator on a three-headed SPECT system, Med. Phys. vol. 23, pp. 263-272, Feb., 1996.
    • (1996) Med. Phys. , vol.23 , pp. 263-272
    • King, M.A.1    Luo, D.-S.2    Dahlberg, S.T.3    Villegas, B.J.4
  • 10
    • 0031930009 scopus 로고    scopus 로고
    • Effect of truncated projections on defect detection in attenuation compensated fan-beam cardiac SPECT
    • B. M. W. Tsui and G. T. Gullberg, Jan.
    • G. K. Gregario, B. M. W. Tsui and G. T. Gullberg, Effect of truncated projections on defect detection in attenuation compensated fan-beam cardiac SPECT, J. Nuc. Med. vol. 39, pp. 166-175, Jan., 1998.
    • (1998) J. Nuc. Med. , vol.39 , pp. 166-175
    • Gregario, G.K.1
  • 12
    • 0004319395 scopus 로고
    • Design of an efficient 3-D projector and backprojector pair for SPECT, in
    • D.-S. Luo and M. A. King
    • T.-S. Pan, D.-S. Luo and M. A. King, Design of an efficient 3-D projector and backprojector pair for SPECT, in Proceedings of Fully 3 D Image Reconstruction in Radiology and Nuclear Medicine (Aix-les-Bains, Savoie, France), pp. 181-185, 1995.
    • (1995) Proceedings of Fully , vol.3 , pp. 181-185
    • Pan, T.-S.1
  • 14
    • 0023363121 scopus 로고
    • A theoretical study of some maximum likelihood algorithms for emission and transmission tomography
    • June
    • K. Lange, M. Bahn and R. Little, A theoretical study of some maximum likelihood algorithms for emission and transmission tomography, IEEE Trans. Med. Imag., vol. 6, pp. 106-114, June, 1987.
    • (1987) IEEE Trans. Med. Imag. , vol.6 , pp. 106-114
    • Lange, K.1    Bahn, M.2    Little, R.3
  • 15
    • 0028700063 scopus 로고
    • Accelerated Image Reconstruction using ordered subsets of projection data
    • Dec.
    • H. M. Hudson and R. S. Larkin, Accelerated Image Reconstruction using ordered subsets of projection data, IEEE Trans. Med. Imag., vol. 13, pp. 601-609, Dec., 1994.
    • (1994) IEEE Trans. Med. Imag. , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 16
    • 0021998326 scopus 로고
    • Quantification of rotational thallium-210 myocardial tomography
    • Jan.
    • E. V. Garcia, K. V. Train, J. Maddahi et al, Quantification of rotational thallium-210 myocardial tomography, J. Nuc. Med. vol. 26, pp. 17-26, Jan., 1985.
    • (1985) J. Nuc. Med. , vol.26 , pp. 17-26
    • Garcia, E.V.1    Train, K.V.2    Maddahi, J.3
  • 17
    • 0025810454 scopus 로고
    • Orbit related variation in spatial resolution as a source of artifactual defects in Thallium-201 SPECT
    • May
    • P. J. Maniawski, H. T. Morgan, F. J. Wackers, Orbit related variation in spatial resolution as a source of artifactual defects in Thallium-201 SPECT, J. Nuc. Med., vol. 32, pp. 871-875, May, 1991
    • (1991) J. Nuc. Med. , vol.32 , pp. 871-875
    • Maniawski, P.J.1    Morgan, H.T.2    Wackers, F.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.