Periotest method: Implant-supported framework fit evaluation in vivo

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ANALYSIS OF VARIANCE; ARTICLE; BONE REGENERATION; DENTAL CARE; DENTURE; FEMALE; HUMAN; IMAGE PROCESSING; INSTRUMENTATION; LASER; MALE; MANDIBLE; MIDDLE AGED; PROSTHESIS; REGRESSION ANALYSIS; REPRODUCIBILITY; TOOTH PROSTHESIS; VIDEORECORDING;

EID: 0032089109     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-3913(98)70071-X     Document Type: Article
Times cited : (15)

References (19)
  • 1
    • 0028185282 scopus 로고
    • Prosthodontic complications in osseointegrated dental implant treatment
    • Carlsson B., and Carlsson G.E. Prosthodontic complications in osseointegrated dental implant treatment. Int J Oral Maxillofac Implants 9 (1994) 90-94
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 90-94
    • Carlsson, B.1    Carlsson, G.E.2
  • 2
    • 0023546198 scopus 로고
    • Osseointegration of bone implants: a review of alternative mode of fixation
    • Albrektsson T., and Albrektsson B. Osseointegration of bone implants: a review of alternative mode of fixation. Acta Orthop Scand 58 (1987) 567-577
    • (1987) Acta Orthop Scand , vol.58 , pp. 567-577
    • Albrektsson, T.1    Albrektsson, B.2
  • 3
    • 0016718745 scopus 로고
    • An evaluation of clinical tooth mobility measurements
    • Laster L., Laudenbach K.W., and Stoller N.H. An evaluation of clinical tooth mobility measurements. J Periodontol 46 (1975) 603-607
    • (1975) J Periodontol , vol.46 , pp. 603-607
    • Laster, L.1    Laudenbach, K.W.2    Stoller, N.H.3
  • 5
    • 0015209415 scopus 로고
    • The estimation of cement film thickness by an in vivo technique
    • McLean J.M., and von Fraunhofer J.A. The estimation of cement film thickness by an in vivo technique. Br Dent J 131 (1971) 107-111
    • (1971) Br Dent J , vol.131 , pp. 107-111
    • McLean, J.M.1    von Fraunhofer, J.A.2
  • 6
    • 28644436196 scopus 로고
    • Special Publication from the Deutscher Zahnarztekalender, Tubingen
    • Schulte W. The Periotest method (1989), Special Publication from the Deutscher Zahnarztekalender, Tubingen 3-14
    • (1989) The Periotest method , pp. 3-14
    • Schulte, W.1
  • 8
    • 0030229407 scopus 로고    scopus 로고
    • The Periotest method: implant supported framework precision of fit evaluation
    • May K.B., Edge M.J., Lang B.R., and Wang R.F. The Periotest method: implant supported framework precision of fit evaluation. J Prosthdont 5 (1996) 206-213
    • (1996) J Prosthdont , vol.5 , pp. 206-213
    • May, K.B.1    Edge, M.J.2    Lang, B.R.3    Wang, R.F.4
  • 9
    • 58149426003 scopus 로고
    • A study of the accuracy of hydrocolloid impressions
    • Skinner E.W., and Hoblit N.E. A study of the accuracy of hydrocolloid impressions. J Prosthet Dent 6 (1956) 80-86
    • (1956) J Prosthet Dent , vol.6 , pp. 80-86
    • Skinner, E.W.1    Hoblit, N.E.2
  • 14
    • 0031301642 scopus 로고    scopus 로고
    • Fit of implant frameworks fabricated by different techniques
    • Riedy S.J., Lang B.R., Vasalic M., and Lang B.E. Fit of implant frameworks fabricated by different techniques. J Prosthet Dent 78 (1997) 596-604
    • (1997) J Prosthet Dent , vol.78 , pp. 596-604
    • Riedy, S.J.1    Lang, B.R.2    Vasalic, M.3    Lang, B.E.4
  • 15
    • 0029174071 scopus 로고
    • Mechanical state assessment of the implant-bone continuum: a better understanding of the Periotest method
    • Trico J., Laohapand P., van Steenberghe D., Querynen M., and Naert I. Mechanical state assessment of the implant-bone continuum: a better understanding of the Periotest method. Int J Oral Maxillofac Implants 10 (1995) 43-49
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 43-49
    • Trico, J.1    Laohapand, P.2    van Steenberghe, D.3    Querynen, M.4    Naert, I.5
  • 16
    • 0029264675 scopus 로고
    • Damping characteristics of bone-to-implant interfaces. A clinical study with the Periotest device
    • van Steenberghe D., Trico J., Naert I., and Nys M. Damping characteristics of bone-to-implant interfaces. A clinical study with the Periotest device. Clin Oral Implants Res 6 (1995) 31-39
    • (1995) Clin Oral Implants Res , vol.6 , pp. 31-39
    • van Steenberghe, D.1    Trico, J.2    Naert, I.3    Nys, M.4
  • 18
    • 0025654203 scopus 로고
    • Periotest method as a measure of osseointegrated oral implant stability. Int
    • Olivé J., and Aparicio C. Periotest method as a measure of osseointegrated oral implant stability. Int. J Oral Maxillofac Implants 5 (1990) 390-400
    • (1990) J Oral Maxillofac Implants , vol.5 , pp. 390-400
    • Olivé, J.1    Aparicio, C.2
  • 19
    • 0025622922 scopus 로고
    • Tissue integration of non-submerged implants. 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants
    • Buser D., Weber H.P., and Lang N.P. Tissue integration of non-submerged implants. 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants. Clin Oral Implants Res 1 (1990) 33-40
    • (1990) Clin Oral Implants Res , vol.1 , pp. 33-40
    • Buser, D.1    Weber, H.P.2    Lang, N.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.