The latest in ultrasound: Three-dimensional imaging. Part II

Author keywords

Catheter; Color Doppler images; Ultrasound

Indexed keywords

COLOR IMAGE PROCESSING; CONTRAST MEDIA; DIAGNOSIS; DOPPLER EFFECT; IMAGE RECONSTRUCTION; ULTRASONIC IMAGING;

EID: 0032077549     PISSN: 0720048X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0720-048X(98)00077-1     Document Type: Conference Paper
Times cited : (51)

References (29)
  • 1
    • 0031238472 scopus 로고    scopus 로고
    • Use of three-dimensional sonomicrometry to study the motion of the mitral valve
    • Vesely I., Fawzy H.F., Fukamachi K., Drake M. Jr Use of three-dimensional sonomicrometry to study the motion of the mitral valve. ASAIO J. 43:1997;465-469.
    • (1997) ASAIO J , vol.43 , pp. 465-469
    • Vesely, I.1    Fawzy, H.F.2    Fukamachi, K.3    Drake M., Jr.4
  • 2
    • 0030470496 scopus 로고    scopus 로고
    • Sonohysterosalpingography with transvaginal color-Doppler and three-dimensional ultrasound: State of the art
    • Bonilla-Musoles F., Raga F., Blanes J. et al. Sonohysterosalpingography with transvaginal color-Doppler and three-dimensional ultrasound: state of the art. J Gynecol Surg. 12/4:1996;227-240.
    • (1996) J Gynecol Surg , vol.124 , pp. 227-240
    • Bonilla-Musoles, F.1    Raga, F.2    Blanes, J.3
  • 3
    • 0031194435 scopus 로고    scopus 로고
    • Accuracy of three-dimensional (3D) ultrasonography in volume estimation of cervical carcinoma
    • Chou C.Y., Hsu K.F., Wang S.T. et al. Accuracy of three-dimensional (3D) ultrasonography in volume estimation of cervical carcinoma. Gynecol Oncol. 66:1997;89-93.
    • (1997) Gynecol Oncol , vol.66 , pp. 89-93
    • Chou, C.Y.1    Hsu, K.F.2    Wang, S.T.3
  • 4
    • 0031020607 scopus 로고    scopus 로고
    • The accuracy of a new system for estimating organ volume using ultrasound
    • Hughes S.W., D'Arcy T.J., Maxwell D.J. et al. The accuracy of a new system for estimating organ volume using ultrasound. Physiol Meas. 18:1997;73-84.
    • (1997) Physiol Meas , vol.18 , pp. 73-84
    • Hughes, S.W.1    D'Arcy, T.J.2    Maxwell, D.J.3
  • 5
    • 0030823771 scopus 로고    scopus 로고
    • Impact of ultrasound and computed tomography prostate volume registration on evaluation of permanent prostate implants
    • Narayana V., Robertson P.L., Winfield R.J., Mc Laughlin P.W. Impact of ultrasound and computed tomography prostate volume registration on evaluation of permanent prostate implants. Int J Radiat Oncol Biol Phys. 39:1997;341-346.
    • (1997) Int J Radiat Oncol Biol Phys , vol.39 , pp. 341-346
    • Narayana, V.1    Robertson, P.L.2    Winfield, R.J.3    Mc Laughlin, P.W.4
  • 6
    • 0031171025 scopus 로고    scopus 로고
    • 3D reconstruction of prostate from ultrasound images
    • Crivianu-Gaita D., Miclea F., Gaspar A. et al. 3D reconstruction of prostate from ultrasound images. Int J Med Inf. 45:1997;43-51.
    • (1997) Int J Med Inf , vol.45 , pp. 43-51
    • Crivianu-Gaita, D.1    Miclea, F.2    Gaspar, A.3
  • 7
    • 0026826480 scopus 로고
    • Anatomic realism comes to diagnostic imaging
    • Hohne K.H. Anatomic realism comes to diagnostic imaging. Diagn Imaging. 14:1992;115-121.
    • (1992) Diagn Imaging , vol.14 , pp. 115-121
    • Hohne, K.H.1
  • 8
    • 0028237361 scopus 로고
    • Three-dimensional ultrasonography in hepatobiliary and pancreatic diseases
    • Sackman M., Pauletzki J., Zwiebel F.M., Holl J. Three-dimensional ultrasonography in hepatobiliary and pancreatic diseases. Bildebung. 61:1994;104-109.
    • (1994) Bildebung , vol.61 , pp. 104-109
    • Sackman, M.1    Pauletzki, J.2    Zwiebel, F.M.3    Holl, J.4
  • 9
    • 0345715918 scopus 로고
    • Ranking R. 3-D allows interactive slicing of sonograms
    • Fenster A, Downey D, Ranking R. 3-D allows interactive slicing of sonograms. Volume Rendering 1994;11-14.
    • (1994) Volume Rendering , pp. 11-14
    • Fenster, A.1    Downey, D.2
  • 12
    • 0027490323 scopus 로고
    • Three-dimensional sonographic reconstruction: Techniques and diagnostic applications
    • Rankin R.N., Fenster A., Downey D.B. et al. Three-dimensional sonographic reconstruction: techniques and diagnostic applications. Am J Roentgenol. 161:1993;695-702.
    • (1993) Am J Roentgenol , vol.161 , pp. 695-702
    • Rankin, R.N.1    Fenster, A.2    Downey, D.B.3
  • 13
    • 0027476738 scopus 로고
    • Clinical application of three-dimensional sonography in internal medicine
    • Zoller W.G., Lieb H., Roth C.M., Umgelter A. Clinical application of three-dimensional sonography in internal medicine. Clin Invest. 71:1993;226-232.
    • (1993) Clin Invest , vol.71 , pp. 226-232
    • Zoller, W.G.1    Lieb, H.2    Roth, C.M.3    Umgelter, A.4
  • 14
    • 0026076508 scopus 로고
    • Three-dimensional (3D) ultrasound imaging of the gallbladder and dilated biliary tree: Reconstruction from real-time B-scans
    • Fine D., Perring S., Herbetto J. et al. Three-dimensional (3D) ultrasound imaging of the gallbladder and dilated biliary tree: reconstruction from real-time B-scans. Br J Radiol. 64:1991;1056-1057.
    • (1991) Br J Radiol , vol.64 , pp. 1056-1057
    • Fine, D.1    Perring, S.2    Herbetto, J.3
  • 15
    • 0031253047 scopus 로고    scopus 로고
    • Three-dimensional endoscopic ultrasound of the esophagus. Preliminary experience
    • Hunerbein M., Gretschel S., Ghadimi B.M., Schlag P.M. Three-dimensional endoscopic ultrasound of the esophagus. Preliminary experience. Surg Endosc. 11:1997;991-994.
    • (1997) Surg Endosc , vol.11 , pp. 991-994
    • Hunerbein, M.1    Gretschel, S.2    Ghadimi, B.M.3    Schlag, P.M.4
  • 16
    • 0042955242 scopus 로고    scopus 로고
    • Three-dimensional endosonography for staging of rectal cancer
    • Hunerbein M., Schlag P.M. Three-dimensional endosonography for staging of rectal cancer. Ann Surg. 225:1997;432-438.
    • (1997) Ann Surg , vol.225 , pp. 432-438
    • Hunerbein, M.1    Schlag, P.M.2
  • 17
    • 0029778554 scopus 로고    scopus 로고
    • Evaluation and biopsy of recurrent rectal cancer using three-dimensional endosonography
    • Hunerbein M., Dohmoto M., Haensch W., Schlag P.M. Evaluation and biopsy of recurrent rectal cancer using three-dimensional endosonography. Dis Colon Rectum. 39/12:1996;1373-1378.
    • (1996) Dis Colon Rectum , vol.3912 , pp. 1373-1378
    • Hunerbein, M.1    Dohmoto, M.2    Haensch, W.3    Schlag, P.M.4
  • 18
    • 0031195548 scopus 로고    scopus 로고
    • Comparison of image processing techniques (magnetic resonance imaging, computed tomography scan and ultrasound) for 3D modeling and analysis of the human bones
    • Metha B.V., Rajani S., Sinha G. Comparison of image processing techniques (magnetic resonance imaging, computed tomography scan and ultrasound) for 3D modeling and analysis of the human bones. J Digit Imaging. 10(suppl 1):1997;203-206.
    • (1997) J Digit Imaging , vol.10 , Issue.SUPPL. 1 , pp. 203-206
    • Metha, B.V.1    Rajani, S.2    Sinha, G.3
  • 19
    • 0031023323 scopus 로고    scopus 로고
    • Visualization of the cerebral circulation using three-dimensional transcranial power Doppler ultrasound imaging
    • Lyden P.D., Nelson T.R. Visualization of the cerebral circulation using three-dimensional transcranial power Doppler ultrasound imaging. J Neuroimaging. 7(1):1997;35-39.
    • (1997) J Neuroimaging , vol.7 , Issue.1 , pp. 35-39
    • Lyden, P.D.1    Nelson, T.R.2
  • 20
    • 0029970224 scopus 로고    scopus 로고
    • Three-dimensional ultrasonic angiography using power-mode Doppler
    • Ritchie C.J., Edwards W.S., Mack L.A., Cyr D.R., Kim Y. Three-dimensional ultrasonic angiography using power-mode Doppler. Ultrasound Med Biol. 22(3):1996;277-286.
    • (1996) Ultrasound Med Biol , vol.22 , Issue.3 , pp. 277-286
    • Ritchie, C.J.1    Edwards, W.S.2    Mack, L.A.3    Cyr, D.R.4    Kim, Y.5
  • 21
    • 0029395713 scopus 로고
    • The clinical value of three-dimensional intravascular ultrasound imaging
    • Reid D.B., Douglas M., Diethrich E.B. The clinical value of three-dimensional intravascular ultrasound imaging. J Endovasc Surg. 2(4):1995;356-364.
    • (1995) J Endovasc Surg , vol.2 , Issue.4 , pp. 356-364
    • Reid, D.B.1    Douglas, M.2    Diethrich, E.B.3
  • 22
    • 0030299978 scopus 로고    scopus 로고
    • 3-D reconstruction of intracranial vessels using a color Doppler energy method-initial experiences
    • Berger G., Rosch P., Steffgen L. 3-D reconstruction of intracranial vessels using a color Doppler energy method-initial experiences. Ultraschall Med. 17(6):1996;277-280.
    • (1996) Ultraschall Med , vol.17 , Issue.6 , pp. 277-280
    • Berger, G.1    Rosch, P.2    Steffgen, L.3
  • 23
    • 0030813329 scopus 로고    scopus 로고
    • A new method for imaging intracranial cerebral arteries - 3-dimensional transcranial duplex ultrasonography with image enhancement
    • Delcker A., Turowski B. A new method for imaging intracranial cerebral arteries - 3-dimensional transcranial duplex ultrasonography with image enhancement. Ultraschall Med. 19(3):1997;110-115.
    • (1997) Ultraschall Med , vol.19 , Issue.3 , pp. 110-115
    • Delcker, A.1    Turowski, B.2
  • 24
    • 8544234956 scopus 로고    scopus 로고
    • Diagnostic value of three-dimensional transcranial contrast duplex sonography
    • Delcker A., Turowski B. Diagnostic value of three-dimensional transcranial contrast duplex sonography. J Neuroimaging. 7(3):1997;139-144.
    • (1997) J Neuroimaging , vol.7 , Issue.3 , pp. 139-144
    • Delcker, A.1    Turowski, B.2
  • 25
    • 0031014489 scopus 로고    scopus 로고
    • Three-dimensional ultrasound angiography (power mode) for the quantification of carotid artery atherosclerosis
    • Griewing B., Schminke U., Morgenstern C., Walker M.L., Kessler C. Three-dimensional ultrasound angiography (power mode) for the quantification of carotid artery atherosclerosis. J Neuroimaging. 7(1):1997;40-45.
    • (1997) J Neuroimaging , vol.7 , Issue.1 , pp. 40-45
    • Griewing, B.1    Schminke, U.2    Morgenstern, C.3    Walker, M.L.4    Kessler, C.5
  • 26
    • 0027298133 scopus 로고
    • Dynamic 3D imaging of peripheral vessels using color-coded Doppler ultrasound
    • Trattnig S., Braunschweig R., Fleiter T. Dynamic 3D imaging of peripheral vessels using color-coded Doppler ultrasound. Ultraschall Med. 14(2):1993;85-89.
    • (1993) Ultraschall Med , vol.14 , Issue.2 , pp. 85-89
    • Trattnig, S.1    Braunschweig, R.2    Fleiter, T.3
  • 28
    • 0030771413 scopus 로고    scopus 로고
    • Vascular imaging by ultrasound: 3D reconstruction of flow velocity fields for endothelial shear stress calculation
    • Adam D.R., Burnstein P. Vascular imaging by ultrasound: 3D reconstruction of flow velocity fields for endothelial shear stress calculation. Adv Exp Med Biol. 430:1997;177-185.
    • (1997) Adv Exp Med Biol , vol.430 , pp. 177-185
    • Adam, D.R.1    Burnstein, P.2
  • 29
    • 0030296466 scopus 로고    scopus 로고
    • The effect of vascular curvature on three-dimensional reconstruction of intravascular ultrasound images