메뉴 건너뛰기




Volumn 38, Issue 5-6, 1998, Pages 657-662

The importance of surface roughness for implant incorporation

(1)  Wennerberg, Ann a  

a NONE

Author keywords

[No Author keywords available]

Indexed keywords

IMPLANTS (SURGICAL); LASER APPLICATIONS; LIVING SYSTEMS STUDIES; ROUGHNESS MEASUREMENT;

EID: 0032068520     PISSN: 08906955     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0890-6955(97)00114-4     Document Type: Article
Times cited : (81)

References (11)
  • 4
    • 0025900565 scopus 로고
    • Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature
    • Buser, D., Schenk, R.K., Steinemann, S., Fiorellini, J.P., Fox, C.H. Stich, H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature. J Biomed Mater Res 25 (1991) pp. 889-902.
    • (1991) J Biomed Mater Res , vol.25 , pp. 889-902
    • Buser, D.1    Schenk, R.K.2    Steinemann, S.3    Fiorellini, J.P.4    Fox, C.H.5    Stich, H.6
  • 6
    • 0001047699 scopus 로고
    • Die trenn-dünnschliff-technik zur herstellung histologischer präparate von nicht schneidbaren geweben und materialien
    • Donath, K. Die trenn-dünnschliff-technik zur herstellung histologischer präparate von nicht schneidbaren geweben und materialien. Der Präparator 34, (1988) pp. 197-206.
    • (1988) Der Präparator , vol.34 , pp. 197-206
    • Donath, K.1
  • 7
    • 0024061747 scopus 로고
    • Clinical and statistical analyses of human clinical trials with single crystal aluminum oxide endosteal dental implants: Five-year results
    • Koth, D.L., McKinney, R.V., Steflik, D.E. Clinical and statistical analyses of human clinical trials with single crystal aluminum oxide endosteal dental implants: Five-year results. J Prosthet Dent 60, (1988) pp. 226-234.
    • (1988) J Prosthet Dent , vol.60 , pp. 226-234
    • Koth, D.L.1    McKinney, R.V.2    Steflik, D.E.3
  • 9
    • 0025394897 scopus 로고
    • Clinical report on the success of 47 consecutive placed core-vent implants followed from 3 months to 4 years
    • Malmquist, J., Sennerby, L. Clinical report on the success of 47 consecutive placed core-vent implants followed from 3 months to 4 years. Int J Oral Maxillofac Implants 5, (1990) pp. 53-60.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 53-60
    • Malmquist, J.1    Sennerby, L.2
  • 11
    • 84974977520 scopus 로고
    • Biocompatibitity: Performance in the surgical reconstruction of man
    • Williams, D.F. Biocompatibitity: Performance in the surgical reconstruction of man. Interdisciplinary Science Reviews 15, (1990) pp. 20-33.
    • (1990) Interdisciplinary Science Reviews , vol.15 , pp. 20-33
    • Williams, D.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.