메뉴 건너뛰기




Volumn 41, Issue 1, 1998, Pages 13-19

Spatial reproducibility of the ring and tandem high-dose rate cervix applicator

Author keywords

Applicator reproducibility; Cancer of cervix; High dose rate brachytherapy

Indexed keywords

ARTICLE; BEAM THERAPY; BRACHYTHERAPY; CLINICAL ARTICLE; HUMAN; PRIORITY JOURNAL; RADIATION DOSE; UTERINE CERVIX; UTERINE CERVIX CANCER;

EID: 0032055004     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(98)00026-1     Document Type: Article
Times cited : (50)

References (14)
  • 1
    • 0002290120 scopus 로고
    • An assessment of calculated doses in intracavitary gynecologic radiotherapy
    • Ljunggren L., Wyman D., Harley L. An assessment of calculated doses in intracavitary gynecologic radiotherapy. Med. Dosim. 12:1987;15-17.
    • (1987) Med. Dosim. , vol.12 , pp. 15-17
    • Ljunggren, L.1    Wyman, D.2    Harley, L.3
  • 4
    • 0028935446 scopus 로고
    • Major geometric variation between multiple high dose-rate applications of brachytherapy in cancer of the cervix: Frequency and types of variation
    • Kim R. Y., Meyer J. T., Plott W. E., Spencer S. A., Meredith R. F., Jenelle R. L. S., Salter M. M. Major geometric variation between multiple high dose-rate applications of brachytherapy in cancer of the cervix Frequency and types of variation . Radiology. 195:1995;419-422.
    • (1995) Radiology , vol.195 , pp. 419-422
    • Kim, R.Y.1    Meyer, J.T.2    Plott, W.E.3    Spencer, S.A.4    Meredith, R.F.5    Jenelle, R.L.S.6    Salter, M.M.7
  • 5
    • 0030586015 scopus 로고    scopus 로고
    • Major geometric variations between intracavitary applications in carcinoma of the cervix: High dose rate vs. low dose rate
    • Kim R. Y., Meyer J. T., Spencer S. A., Meredith R. F., Jenelle R. L. S., Salter M. M. Major geometric variations between intracavitary applications in carcinoma of the cervix High dose rate vs. low dose rate . Int. J. Radiat. Oncol. Biol. Phys. 35:1996;1035-1038.
    • (1996) Int. J. Radiat. Oncol. Biol. Phys. , vol.35 , pp. 1035-1038
    • Kim, R.Y.1    Meyer, J.T.2    Spencer, S.A.3    Meredith, R.F.4    Jenelle, R.L.S.5    Salter, M.M.6
  • 6
    • 0021812109 scopus 로고
    • The application of the linear-quadratic dose effect equation to fractionated and protracted radiotherapy
    • Dale R. G. The application of the linear-quadratic dose effect equation to fractionated and protracted radiotherapy. Br. J. Radiother. 58:1985;515-528.
    • (1985) Br. J. Radiother. , vol.58 , pp. 515-528
    • Dale, R.G.1
  • 9
    • 0024448603 scopus 로고
    • Radiation alone in the treatment of cancer of the uterine cancer:Analysis of pelvic failure and dose response relationship
    • Kim R. Y., Trotti A., Wu C. J., Soong S. J., Salter M. M. Radiation alone in the treatment of cancer of the uterine cancer:Analysis of pelvic failure and dose response relationship. Int. J. Radiat. Oncol. Biol. Phys. 17:1989;973-978.
    • (1989) Int. J. Radiat. Oncol. Biol. Phys. , vol.17 , pp. 973-978
    • Kim, R.Y.1    Trotti, A.2    Wu, C.J.3    Soong, S.J.4    Salter, M.M.5
  • 10
    • 0026032038 scopus 로고
    • Patterns and sites of failure in cervix cancer treated in the USA in 1978
    • Montana G. S., Martz K. L., Hanks G. E. Patterns and sites of failure in cervix cancer treated in the USA in 1978. Int. J. Radiat. Oncol. Biol. Phys. 20:1991;87-93.
    • (1991) Int. J. Radiat. Oncol. Biol. Phys. , vol.20 , pp. 87-93
    • Montana, G.S.1    Martz, K.L.2    Hanks, G.E.3
  • 11
    • 0026550050 scopus 로고
    • Effect of tumor size on the prognosis of carcinoma of the uterine cervix treated with irradiation alone
    • Perez C. A., Grigsby P. W., Nene S. M., Camel H. M., Galakatos A., Kao M. S., Lockett M. A. Effect of tumor size on the prognosis of carcinoma of the uterine cervix treated with irradiation alone. Cancer. 69:1992;2796-2806.
    • (1992) Cancer , vol.69 , pp. 2796-2806
    • Perez, C.A.1    Grigsby, P.W.2    Nene, S.M.3    Camel, H.M.4    Galakatos, A.5    Kao, M.S.6    Lockett, M.A.7
  • 13
    • 0030175512 scopus 로고    scopus 로고
    • Dose-volume histogram analysis of high dose rate intracavitary brachytherapy for uterine cervix cancer
    • Terahara A., Nakano T., Ishikawa A., Morita S., Tsujii H. Dose-volume histogram analysis of high dose rate intracavitary brachytherapy for uterine cervix cancer. Int. J. Radiat. Oncol. Biol. Phys. 35:1996;549-554.
    • (1996) Int. J. Radiat. Oncol. Biol. Phys. , vol.35 , pp. 549-554
    • Terahara, A.1    Nakano, T.2    Ishikawa, A.3    Morita, S.4    Tsujii, H.5
  • 14
    • 0010639867 scopus 로고
    • High-dose-rate vs. low-dose-rate intracavitary brachytherapy for carcinoma of the cervix
    • Fu F. K., Philips T. L. High-dose-rate vs. low-dose-rate intracavitary brachytherapy for carcinoma of the cervix. Int. J. Radiat. Oncol. Biol. Phys. 20:1991;915-919.
    • (1991) Int. J. Radiat. Oncol. Biol. Phys. , vol.20 , pp. 915-919
    • Fu, F.K.1    Philips, T.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.