메뉴 건너뛰기




Volumn 41, Issue 1, 1998, Pages 233-237

Evaluation of eye shields made of tungsten and aluminum in high-energy electron beams

Author keywords

Backscattered electrons; Electron beams; Eye Shielding; Lead; Transmission; Tungsten

Indexed keywords

ALUMINUM; LEAD; TUNGSTEN;

EID: 0032054761     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(97)00905-X     Document Type: Article
Times cited : (30)

References (12)
  • 1
    • 0018852041 scopus 로고
    • Individualized eye shields for use in electron beam therapy as well as low-energy photon irradiation
    • Asbell S. O., Siu J., Lightfoot D. A., Brady L. W. Individualized eye shields for use in electron beam therapy as well as low-energy photon irradiation. Int. J. Radiat. Oncol. 6:1980;519-521.
    • (1980) Int. J. Radiat. Oncol. , vol.6 , pp. 519-521
    • Asbell, S.O.1    Siu, J.2    Lightfoot, D.A.3    Brady, L.W.4
  • 2
    • 0022655824 scopus 로고
    • Dose distribution under external eye shields for high energy electrons
    • Rustgi S. N. Dose distribution under external eye shields for high energy electrons. Int. J. Radiat. Oncol. 12:1986;141-144.
    • (1986) Int. J. Radiat. Oncol. , vol.12 , pp. 141-144
    • Rustgi, S.N.1
  • 3
    • 0016717986 scopus 로고
    • Lead shielding thickness for dose reduction of 7-28 MeV electrons
    • Giarratano J. C., Duerkes R. J., Almond P. R. Lead shielding thickness for dose reduction of 7-28 MeV electrons. Med. Phys. 2:1975;336-337.
    • (1975) Med. Phys. , vol.2 , pp. 336-337
    • Giarratano, J.C.1    Duerkes, R.J.2    Almond, P.R.3
  • 4
    • 0020078495 scopus 로고
    • Backscattering in electron beam therapy for energies between 3 and 35 MeV
    • Klevenhagen S. C., Lambert G. D., Arbari A. Backscattering in electron beam therapy for energies between 3 and 35 MeV. Phys. Med. Biol. 27:1982;363-373.
    • (1982) Phys. Med. Biol. , vol.27 , pp. 363-373
    • Klevenhagen, S.C.1    Lambert, G.D.2    Arbari, A.3
  • 7
    • 0028355398 scopus 로고
    • Systemic delivery of polypeptide drugs through ocular route
    • Chiou G. C. Systemic delivery of polypeptide drugs through ocular route. J. Ocular Pharmacol. 10:1994;93-99.
    • (1994) J. Ocular Pharmacol. , vol.10 , pp. 93-99
    • Chiou, G.C.1
  • 8
    • 0028902207 scopus 로고
    • Leaded eye cosmetics: A cultural cause of elevated lead levels in children
    • Sprinkle R. V. Leaded eye cosmetics A cultural cause of elevated lead levels in children . J. Family Pract. 41:1995;358-362.
    • (1995) J. Family Pract. , vol.41 , pp. 358-362
    • Sprinkle, R.V.1
  • 9
    • 0014662669 scopus 로고
    • Film dosimetry of high-energy electrons
    • Dutreix J., Dutreix A. Film dosimetry of high-energy electrons. Ann. NY Acad. Sci. 161:1969;33-43.
    • (1969) Ann. NY Acad. Sci. , vol.161 , pp. 33-43
    • Dutreix, J.1    Dutreix, A.2
  • 11
    • 0017163013 scopus 로고
    • Field shaping in electron beam therapy
    • Khan F. M., Moore V. C., Levitt S. H. Field shaping in electron beam therapy. Br. J. Radiol. 49:1976;883-886.
    • (1976) Br. J. Radiol. , vol.49 , pp. 883-886
    • Khan, F.M.1    Moore, V.C.2    Levitt, S.H.3
  • 12
    • 0016480599 scopus 로고
    • Physical measurements and clinical observations on the backscatter of 10 MeV electrons from lead shielding
    • Weatherburn H., McMillan K. T. P., Stedford B., Durrant K. R. Physical measurements and clinical observations on the backscatter of 10 MeV electrons from lead shielding. Br. J. Radiol. 48:1975;229-230.
    • (1975) Br. J. Radiol. , vol.48 , pp. 229-230
    • Weatherburn, H.1    McMillan, K.T.P.2    Stedford, B.3    Durrant, K.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.