메뉴 건너뛰기




Volumn 31, Issue 4, 1998, Pages 363-369

A comparative tribological study of the wear of composite cushion cups in a physiological hip joint simulator

Author keywords

Composite cushion bearing; Hip joint simulator; UHMWPE; Wear

Indexed keywords

BIPED LOCOMOTION; COMPOSITE MATERIALS; JOINTS (ANATOMY); LUBRICANTS; LUBRICATION; PHYSIOLOGICAL MODELS; POLYETHYLENES; SURGERY; TRIBOLOGY; WEAR OF MATERIALS;

EID: 0032052512     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0021-9290(98)00034-7     Document Type: Article
Times cited : (31)

References (14)
  • 3
    • 0030623710 scopus 로고    scopus 로고
    • Wear of UHMWPE acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant
    • Bigsby R.J.A., Hardaker C.S., Fisher J. Wear of UHMWPE acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant. Journal of Engineering Medicine. 211:1997;265-269.
    • (1997) Journal of Engineering Medicine , vol.211 , pp. 265-269
    • Bigsby, R.J.A.1    Hardaker, C.S.2    Fisher, J.3
  • 6
    • 0005174844 scopus 로고
    • Design and development of a versatile hip joint simulator
    • Dowson D., Jobbins B. Design and development of a versatile hip joint simulator. Journal of Engineering Medicine. 17:1988;1-6.
    • (1988) Journal of Engineering Medicine , vol.17 , pp. 1-6
    • Dowson, D.1    Jobbins, B.2
  • 7
    • 0027579519 scopus 로고
    • An evaluation of the penetration of ceramic femoral heads into polyethylene acetabular cups
    • Dowson, D., Jobbins, B., Seyed-Harraf, A., 1993. An evaluation of the penetration of ceramic femoral heads into polyethylene acetabular cups. Wear, 880-889.
    • (1993) Wear , pp. 880-889
    • Dowson, D.1    Jobbins, B.2    Seyed-Harraf, A.3
  • 10
    • 0029693843 scopus 로고    scopus 로고
    • Determination of lubricating film thickness for permeable hydrogel and non permeable polyurethane layers bonded to a rigid substrate with particular reference to cushion form hip replacements
    • McClure G., Jin Z.M., Tighe B.J. Determination of lubricating film thickness for permeable hydrogel and non permeable polyurethane layers bonded to a rigid substrate with particular reference to cushion form hip replacements. Proceedings Institution of Mechanical Engineers, Part H. 210(H):1996;89-93.
    • (1996) Proceedings Institution of Mechanical Engineers, Part H , vol.210 , Issue.H , pp. 89-93
    • McClure, G.1    Jin, Z.M.2    Tighe, B.J.3
  • 11
    • 0019001663 scopus 로고
    • Hydrophilic polyurethane elastomers for hemiarthroplasty, A preliminary in vitro wear study
    • Medley J.B., Pilliar R.M., Wong E.W., Strong A.B. Hydrophilic polyurethane elastomers for hemiarthroplasty, A preliminary in vitro wear study. Journal of Engineering Medicine. 9(2):1980;59-65.
    • (1980) Journal of Engineering Medicine , vol.9 , Issue.2 , pp. 59-65
    • Medley, J.B.1    Pilliar, R.M.2    Wong, E.W.3    Strong, A.B.4
  • 14
    • 0015052277 scopus 로고
    • The tribology (friction, lubrication and wear) of all metal artificial hip joints
    • Walker P.S., Gold B.L. The tribology (friction, lubrication and wear) of all metal artificial hip joints. Wear. 17(4):1971;285-299.
    • (1971) Wear , vol.17 , Issue.4 , pp. 285-299
    • Walker, P.S.1    Gold, B.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.