메뉴 건너뛰기




Volumn 74-76, Issue , 1998, Pages 641-649

Modeling pressure equalization in cavities

Author keywords

[No Author keywords available]

Indexed keywords

CAVITATION; FACADES; MATHEMATICAL MODELS; PRESSURE MEASUREMENT; RAIN; TIME SERIES ANALYSIS; TRANSFER FUNCTIONS;

EID: 0032051907     PISSN: 01676105     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-6105(98)00058-0     Document Type: Article
Times cited : (13)

References (6)
  • 1
    • 0028082838 scopus 로고
    • A numerical model to evaluate the performance of pressure equalized rainscreen walls
    • A. Baskaran, A numerical model to evaluate the performance of pressure equalized rainscreen walls, Building Environ. 29 (2) (1994) 159-171.
    • (1994) Building Environ. , vol.29 , Issue.2 , pp. 159-171
    • Baskaran, A.1
  • 2
    • 0025460581 scopus 로고
    • The propagation of internal pressures in buildings
    • R.I. Harris, The propagation of internal pressures in buildings, J. Wind Eng. Ind. Aerodyn. 34 (1990) 169-184.
    • (1990) J. Wind Eng. Ind. Aerodyn. , vol.34 , pp. 169-184
    • Harris, R.I.1
  • 3
    • 0019228554 scopus 로고
    • Mean and fluctuating internal pressures induced by wind
    • J.E. Cermak (Ed), Colorado
    • J.D. Holmes, Mean and fluctuating internal pressures induced by wind, in: J.E. Cermak (Ed), Wind Eng. Proc. Vth Int. Conf., Colorado, 1979, pp. 435-450.
    • (1979) Wind Eng. Proc. Vth Int. Conf. , pp. 435-450
    • Holmes, J.D.1
  • 4
    • 0028534198 scopus 로고
    • Pressure-equalized rainscreens: A study in the frequency domain
    • D.R. Inculet, A.G. Davenport, Pressure-equalized rainscreens: A study in the frequency domain, J. Wind Eng. Ind. Aerodyn. 53 (1994) 63-87.
    • (1994) J. Wind Eng. Ind. Aerodyn. , vol.53 , pp. 63-87
    • Inculet, D.R.1    Davenport, A.G.2
  • 5
    • 0038949148 scopus 로고
    • Pressure equalised rainscreen joint modelling with numerical model PERAM
    • J.C. Burgess, Pressure equalised rainscreen joint modelling with numerical model PERAM, Building Environ. 30 (3) (1995) 385-389.
    • (1995) Building Environ. , vol.30 , Issue.3 , pp. 385-389
    • Burgess, J.C.1
  • 6
    • 0042937068 scopus 로고
    • Coherence of wind induced pressures on the main buildings in urban areas: Set up of a full scale experiment
    • C.P.W. Geurts, H.S. Rutten, J.A. Wisse, Coherence of wind induced pressures on the main buildings in urban areas: Set up of a full scale experiment, East European Conf. on Wind Engineering, Vol. 2, 1994, pp. 17-27.
    • (1994) East European Conf. on Wind Engineering , vol.2 , pp. 17-27
    • Geurts, C.P.W.1    Rutten, H.S.2    Wisse, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.