메뉴 건너뛰기




Volumn 13, Issue 4, 1998, Pages 847-849

Merits of percentage hypochromic red cells as a marker of functional iron deficiency

Author keywords

[No Author keywords available]

Indexed keywords

IRON; RECOMBINANT ERYTHROPOIETIN;

EID: 0032041971     PISSN: 09310509     EISSN: None     Source Type: Journal    
DOI: 10.1093/ndt/13.4.847     Document Type: Article
Times cited : (54)

References (25)
  • 1
    • 0023120533 scopus 로고
    • Correction of the anemia of end-stage renal disease with recombinant human erythropoietin
    • Eschbach JW, Egrie JC, Downing MR, Browne JK, Adamson JW. Correction of the anemia of end-stage renal disease with recombinant human erythropoietin. N Engl J Med 1987; 316: 73-78
    • (1987) N Engl J Med , vol.316 , pp. 73-78
    • Eschbach, J.W.1    Egrie, J.C.2    Downing, M.R.3    Browne, J.K.4    Adamson, J.W.5
  • 3
    • 0021016658 scopus 로고
    • Serum ferritin and bone marrow iron in patients undergoing continuous ambulatory peritoneal dialysis
    • Blumberg AB, Marti HRM, Graber CG. Serum ferritin and bone marrow iron in patients undergoing continuous ambulatory peritoneal dialysis. JAMA 1983; 250: 3317-3319
    • (1983) JAMA , vol.250 , pp. 3317-3319
    • Blumberg, A.B.1    Marti, H.R.M.2    Graber, C.G.3
  • 5
    • 0017703490 scopus 로고
    • Ferritin synthesis in inflammation: Pathogenesis of impaired iron release
    • Konijn AM, Hershko C. Ferritin synthesis in inflammation: pathogenesis of impaired iron release. Br J Haem 1977; 37: 7 16
    • (1977) Br J Haem , vol.37 , pp. 716
    • Konijn, A.M.1    Hershko, C.2
  • 6
    • 0018116728 scopus 로고
    • Serum ferritin during infection: A longitudinal study
    • Birgegard G, Hallgren R, Killander A. Serum ferritin during infection: a longitudinal study. Scand J Haematol 1978; 21: 333-340
    • (1978) Scand J Haematol , vol.21 , pp. 333-340
    • Birgegard, G.1    Hallgren, R.2    Killander, A.3
  • 7
    • 0020144203 scopus 로고
    • Diagnostic methods
    • Cavill I. Diagnostic methods. Clinics Haematol 1982; 11: 259 273
    • (1982) Clinics Haematol , vol.11 , pp. 259-273
    • Cavill, I.1
  • 10
    • 0028239355 scopus 로고
    • Iron metabolism and iron substitution during erythropoietin therapy
    • Sunder-Plassmann G, Horl WH. Iron metabolism and iron substitution during erythropoietin therapy. Clin Investig 1994; 72 (Suppl): S11 S15
    • (1994) Clin Investig , vol.72 , Issue.SUPPL.
    • Sunder-Plassmann, G.1    Horl, W.H.2
  • 11
    • 1842277078 scopus 로고
    • Relationship between transferrin saturation index and red cell size and haemoglobin content in haemodialysis patients
    • Golan E, Radnay J, Goldmann J, Bernheim J, Rathaus M. Relationship between transferrin saturation index and red cell size and haemoglobin content in haemodialysis patients. Nephrol Dial Transplant 1994; 9: 1030
    • (1994) Nephrol Dial Transplant , vol.9 , pp. 1030
    • Golan, E.1    Radnay, J.2    Goldmann, J.3    Bernheim, J.4    Rathaus, M.5
  • 12
    • 0029038363 scopus 로고
    • The hypochromic red cell: A new parameter for monitoring of iron supplementation during rhEPO therapy
    • Schaefer RM, Schaefer L. The hypochromic red cell: a new parameter for monitoring of iron supplementation during rhEPO therapy. J Perinat Med 1995; 23: 83-88
    • (1995) J Perinat Med , vol.23 , pp. 83-88
    • Schaefer, R.M.1    Schaefer, L.2
  • 13
    • 0030918074 scopus 로고    scopus 로고
    • Percentage of hypochromic red blood cells as predictor of erythropoietic and iron response after i.v. iron supplementation in maintenance haemodialysis patients
    • Braun J, Lindner K, Schreiber M, Heidler RA, Horl WH. Percentage of hypochromic red blood cells as predictor of erythropoietic and iron response after i.v. iron supplementation in maintenance haemodialysis patients. Nephrol Dial Transplant 1997; 12: 1173 1181
    • (1997) Nephrol Dial Transplant , vol.12 , pp. 1173-1181
    • Braun, J.1    Lindner, K.2    Schreiber, M.3    Heidler, R.A.4    Horl, W.H.5
  • 14
    • 0030788230 scopus 로고    scopus 로고
    • The dilemma of evaluating iron status in dialysis patients - Limitations of available diagnostic procedures
    • Sunder-Plassmann G, Spitzauer S, Horl WH. The dilemma of evaluating iron status in dialysis patients - limitations of available diagnostic procedures. Nephrol Dial Transplant 1997; 12: 1575-1580
    • (1997) Nephrol Dial Transplant , vol.12 , pp. 1575-1580
    • Sunder-Plassmann, G.1    Spitzauer, S.2    Horl, W.H.3
  • 15
    • 0031109854 scopus 로고    scopus 로고
    • Hypochromic red cells as an indicator of iron deficiency
    • Navarro JF, Macia ML. Hypochromic red cells as an indicator of iron deficiency. J Rheumatol 1997; 24: 804-805
    • (1997) J Rheumatol , vol.24 , pp. 804-805
    • Navarro, J.F.1    Macia, M.L.2
  • 16
    • 0023629991 scopus 로고
    • Can automated hematology analysers discriminate thalassemia from iron deficiency?
    • Marti HR, Fischer S, Killer D, Burgi W. Can automated hematology analysers discriminate thalassemia from iron deficiency? Acta Haematol 1987; 78: 180-183
    • (1987) Acta Haematol , vol.78 , pp. 180-183
    • Marti, H.R.1    Fischer, S.2    Killer, D.3    Burgi, W.4
  • 17
    • 0026584697 scopus 로고
    • Automated measurement of red blood cell microcytosis and hypochromia in iron deficiency and β-thalassemia trait
    • d'Onofrio G, Zini G, Ricerca BM, Mancini S, Mango G. Automated measurement of red blood cell microcytosis and hypochromia in iron deficiency and β-thalassemia trait. Arch Pathol Lab Med 1992; 116: 84-89
    • (1992) Arch Pathol Lab Med , vol.116 , pp. 84-89
    • D'Onofrio, G.1    Zini, G.2    Ricerca, B.M.3    Mancini, S.4    Mango, G.5
  • 18
    • 0027008368 scopus 로고
    • Use of Technicon H*1 technology in routine thalassemia screening
    • Robertson EP, Pollock A, Yau KS, Chan LC. Use of Technicon H*1 technology in routine thalassemia screening. Med Lab Sciences 1992; 49: 259-264
    • (1992) Med Lab Sciences , vol.49 , pp. 259-264
    • Robertson, E.P.1    Pollock, A.2    Yau, K.S.3    Chan, L.C.4
  • 19
    • 0026436740 scopus 로고
    • Measurements of cell volume and hemoglobin concentration of erythrocytes from hereditary ovalocytosis and hereditary spherocytosis
    • Bunyaratvej A, Bunyaratvej P. Measurements of cell volume and hemoglobin concentration of erythrocytes from hereditary ovalocytosis and hereditary spherocytosis. J Med Assoc Thai 1992; 75 (Suppl 1): 248-252
    • (1992) J Med Assoc Thai , vol.75 , Issue.1 SUPPL. , pp. 248-252
    • Bunyaratvej, A.1    Bunyaratvej, P.2
  • 20
    • 0027231262 scopus 로고
    • Membrane properties of erythrocytes in subjects undergoing multiple blood donations with or without recombinant erythropoietin
    • Brugnara C, Kruskall MS, Johnstone RM. Membrane properties of erythrocytes in subjects undergoing multiple blood donations with or without recombinant erythropoietin. Br J Haematol 1993; 84: 118-130
    • (1993) Br J Haematol , vol.84 , pp. 118-130
    • Brugnara, C.1    Kruskall, M.S.2    Johnstone, R.M.3
  • 22
    • 0027973783 scopus 로고
    • Hydration of red cells in α and β thalassemia differs. A useful approach to distinguish between these red cell phenotypes
    • Bunyaratvej A, Fucharoen S, Greenbaum A, Mohandas N. Hydration of red cells in α and β thalassemia differs. A useful approach to distinguish between these red cell phenotypes. Am J Clin Pathol 1994; 102: 217-222
    • (1994) Am J Clin Pathol , vol.102 , pp. 217-222
    • Bunyaratvej, A.1    Fucharoen, S.2    Greenbaum, A.3    Mohandas, N.4
  • 23
    • 0029121768 scopus 로고
    • New indices from the H*2 analyzer improve differentiation between heterozygous β or δβ thalassemia and iron-deficiency anemia
    • Jimenez CV, Minchinela J, Ros J. New indices from the H*2 analyzer improve differentiation between heterozygous β or δβ thalassemia and iron-deficiency anemia. Clin Lab Haem 1995; 17: 151-155
    • (1995) Clin Lab Haem , vol.17 , pp. 151-155
    • Jimenez, C.V.1    Minchinela, J.2    Ros, J.3
  • 24
    • 0030818087 scopus 로고    scopus 로고
    • Reticulocyte hemoglobin content in the evaluation of iron status in hemodialysis patients
    • Fishbane S, Galgano C, Langley RC, Canfield W, Maesaka JK. Reticulocyte hemoglobin content in the evaluation of iron status in hemodialysis patients. Kidney Int 1997; 52: 217-222
    • (1997) Kidney Int , vol.52 , pp. 217-222
    • Fishbane, S.1    Galgano, C.2    Langley, R.C.3    Canfield, W.4    Maesaka, J.K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.