1
-
-
0031000898
-
Nature and determinants of skin "burns" after transthoradc cardioversion
-
Pagan-Carlo LA, Stone MS, Kerber RE. Nature and determinants of skin "burns" after transthoradc cardioversion. J Am Coll Cardiol. 1997;79:689-91.
-
(1997)
J Am Coll Cardiol.
, vol.79
, pp. 689-691
-
-
Pagan-Carlo, L.A.1
Stone, M.S.2
Kerber, R.E.3
-
4
-
-
0039119116
-
Temperature and current-density distributions at electrosurgical dispersive electrode sites
-
Troy, NY.
-
Caruso PM, Pearce JA, DeWitt DP. Temperature and current-density distributions at electrosurgical dispersive electrode sites. Proc 7th New England Bioengineering Conf., Troy, NY. 1979:373-6.
-
(1979)
Proc 7th New England Bioengineering Conf.
, pp. 373-376
-
-
Caruso, P.M.1
Pearce, J.A.2
DeWitt, D.P.3
-
5
-
-
84994954258
-
The effect ofgelled-pad design on the performance of electrosurgical dispersive electrodes
-
Caruso PM, Pearce JA, DeWitt DP. The effect ofgelled-pad design on the performance of electrosurgical dispersive electrodes. Proc ASME Winter Annual Meeting. 1982:1-9.
-
(1982)
Proc ASME Winter Annual Meeting
, pp. 1-9
-
-
Caruso, P.M.1
Pearce, J.A.2
DeWitt, D.P.3
-
6
-
-
0020332065
-
Analysis and control of current distribution under circular dispersive electrodes
-
Wiley JD, Webster JG. Analysis and control of current distribution under circular dispersive electrodes. IEEE Trans. Biomed Eng. 1982;29:381-9.
-
(1982)
IEEE Trans. Biomed Eng.
, vol.29
, pp. 381-389
-
-
Wiley, J.D.1
Webster, J.G.2
-
7
-
-
0022723990
-
Modeling of thermal patterns of electrosurgical dispersive electrodes
-
Aubry-Frize M, Pussant Y. Modeling of thermal patterns of electrosurgical dispersive electrodes. Med Biol Eng Comput. May 1986;24:311-6.
-
(1986)
Med Biol Eng Comput. May
, vol.24
, pp. 311-316
-
-
Aubry-Frize, M.1
Pussant, Y.2
-
9
-
-
85069372654
-
Measurement of temperature distributions at electrosurgical dispersive electrode sites
-
Atlanta, GA
-
Overmeyer KM, Pearce JA, DeWitt DP. Measurement of temperature distributions at electrosurgical dispersive electrode sites. Proc ASME Winter Meeting, Atlanta, GA, 1977, 1-8. See also J Biomech Eng. 1979;101:60-72.
-
(1977)
Proc ASME Winter Meeting
, pp. 1-8
-
-
Overmeyer, K.M.1
Pearce, J.A.2
DeWitt, D.P.3
-
10
-
-
15644361925
-
-
Overmeyer KM, Pearce JA, DeWitt DP. Measurement of temperature distributions at electrosurgical dispersive electrode sites. Proc ASME Winter Meeting, Atlanta, GA, 1977, 1-8. See also J Biomech Eng. 1979;101:60-72.
-
(1979)
J Biomech Eng.
, vol.101
, pp. 60-72
-
-
-
11
-
-
0018511990
-
The thermal behavior of electrolyte-coated metal-foil dispersive electrodes
-
Pearce JA, Geddes LA, Bourland JD, et al. The thermal behavior of electrolyte-coated metal-foil dispersive electrodes. Med Instrum. 1979;13:298-300.
-
(1979)
Med Instrum.
, vol.13
, pp. 298-300
-
-
Pearce, J.A.1
Geddes, L.A.2
Bourland, J.D.3
-
12
-
-
0018873344
-
Thermal properties of dry metal-foil dispersive electrosurgical electrodes
-
Geddes LA, Pearce JA, Bourland JD, et al. Thermal properties of dry metal-foil dispersive electrosurgical electrodes. J Clin Eng. 1980;5(1):13-7.
-
(1980)
J Clin Eng.
, vol.5
, Issue.1
, pp. 13-17
-
-
Geddes, L.A.1
Pearce, J.A.2
Bourland, J.D.3
-
15
-
-
84953656097
-
The relative importance of time and surface temperature in the causation of skin burns
-
Moritz AR, Henriques FC. The relative importance of time and surface temperature in the causation of skin burns. Am J Pathol. 1947;23:695-720.
-
(1947)
Am J Pathol.
, vol.23
, pp. 695-720
-
-
Moritz, A.R.1
Henriques, F.C.2
-
17
-
-
0019570946
-
External noninvasive electrical stimulation of the heart
-
Zoll PM, Zoll RH. External noninvasive electrical stimulation of the heart. Crit Care Med. 1981;9:393-9.
-
(1981)
Crit Care Med.
, vol.9
, pp. 393-399
-
-
Zoll, P.M.1
Zoll, R.H.2
|