메뉴 건너뛰기




Volumn 13, Issue 3-4, 1998, Pages 259-269

Validation of antibody-based recognition by piezoelectric transducers through electroacoustic admittance analysis

Author keywords

Electroacoustic admittance; Enzymes adsorption; Immunosensors; QCM

Indexed keywords

ADSORPTION; ANTIBODIES; BIOSENSORS; ELECTROACOUSTIC TESTING; ENZYME SENSORS; ENZYMES; PIEZOELECTRIC TRANSDUCERS;

EID: 0032029948     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(97)00139-5     Document Type: Article
Times cited : (42)

References (13)
  • 2
    • 0027262446 scopus 로고
    • Study of immunoglobulin g thin layers obtained by the langmuir-blodgett method: Application to immunosensors
    • Barraud, A., Perrot, H., Billard, V., Martelet, C. and Therasse, J. (1993) Study of immunoglobulin G thin layers obtained by the Langmuir-Blodgett method: application to immunosensors, Biosensors & Bioelectronics 8, 39-48.
    • (1993) Biosensors & Bioelectronics , vol.8 , pp. 39-48
    • Barraud, A.1    Perrot, H.2    Billard, V.3    Martelet, C.4    Therasse, J.5
  • 4
    • 0026221304 scopus 로고
    • Calibration of the electrochemical quartz microbalance
    • Gabrielii, C., Keddam, M. and Torresti, R. (1991) Calibration of the electrochemical quartz microbalance. J. Electrochem. Soc. 138, 2657-2660.
    • (1991) J. Electrochem. Soc. , vol.138 , pp. 2657-2660
    • Gabrielii, C.1    Keddam, M.2    Torresti, R.3
  • 6
    • 36449008243 scopus 로고
    • Characterization of a thickness-shear mode quartz resonator with multiple nonpiezoelectric layers
    • Granstaff, V. E. and Martin, S. J. (1994) Characterization of a thickness-shear mode quartz resonator with multiple nonpiezoelectric layers. J. Appl. Phys. 75, 1319-1328.
    • (1994) J. Appl. Phys. , vol.75 , pp. 1319-1328
    • Granstaff, V.E.1    Martin, S.J.2
  • 8
    • 0027918114 scopus 로고
    • Quartz crystal microbalance for the detection of microgram quantities of human serum albumin: Relationship between the frequency change and the mass of protein adsorbed
    • Muratsugu, M., Ohta, F., Miya, Y., Hosokawa, T., Kurosawa, S., Kamo, N. and Ikeda, H. (1993) Quartz crystal microbalance for the detection of microgram quantities of human serum albumin: relationship between the frequency change and the mass of protein adsorbed. Anal. Chem. 65, 2933-2937.
    • (1993) Anal. Chem. , vol.65 , pp. 2933-2937
    • Muratsugu, M.1    Ohta, F.2    Miya, Y.3    Hosokawa, T.4    Kurosawa, S.5    Kamo, N.6    Ikeda, H.7
  • 9
    • 0024121449 scopus 로고
    • Integrated optical input grating couplers as biochemical sensors
    • Nellen, P. M., Tiefenthaler, K. and Lukosz, W. (1988) Integrated optical input grating couplers as biochemical sensors. Sens. Actuators 15, 285-292.
    • (1988) Sens. Actuators , vol.15 , pp. 285-292
    • Nellen, P.M.1    Tiefenthaler, K.2    Lukosz, W.3
  • 10
    • 0001367472 scopus 로고    scopus 로고
    • QCM operation in liquids: Constant sensitivity during formation of extended protein multilayers by affinity
    • Rickert, J., Brecht, A. and Göpel, W. (1997) QCM operation in liquids: constant sensitivity during formation of extended protein multilayers by affinity. Anal. Chem. 69, 1441-1448.
    • (1997) Anal. Chem. , vol.69 , pp. 1441-1448
    • Rickert, J.1    Brecht, A.2    Göpel, W.3
  • 11
    • 0027996780 scopus 로고
    • Recent developments in piezoelectric immunosensors
    • Suleiman, A. A. and Guilbault, G. G. (1994) Recent developments in piezoelectric immunosensors. Analyst 1991, 2279-2282.
    • (1994) Analyst , vol.1991 , pp. 2279-2282
    • Suleiman, A.A.1    Guilbault, G.G.2
  • 12
    • 0025002457 scopus 로고
    • In situ interfacial mass detection with piezoelectric transducers
    • Ward, M. D. and Buttry, D. A. (1991) In situ interfacial mass detection with piezoelectric transducers. Science 249, 1000-1007.
    • (1991) Science , vol.249 , pp. 1000-1007
    • Ward, M.D.1    Buttry, D.A.2
  • 13
    • 0026473016 scopus 로고
    • Thickness-shear mode acoustic wave sensors and flow-injection analysis
    • Yang, M. and Thompson, M. (1992) Thickness-shear mode acoustic wave sensors and flow-injection analysis. Anal. Chim. Acta 269, 167-175.
    • (1992) Anal. Chim. Acta , vol.269 , pp. 167-175
    • Yang, M.1    Thompson, M.2