메뉴 건너뛰기




Volumn 22, Issue 2, 1998, Pages 115-121

Two motion-detection algorithms for projection-reconstruction magnetic resonance imaging: Theory and experimental verification

Author keywords

Artifacts; Magnetic resonance imaging; Medical imaging; Motion; Motion detection; Radiology

Indexed keywords

COMPUTER AIDED DIAGNOSIS; IMAGE RECONSTRUCTION; MEDICAL IMAGING; PERSONAL COMPUTERS; RADIOLOGY;

EID: 0032029023     PISSN: 08956111     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0895-6111(98)00013-5     Document Type: Article
Times cited : (6)

References (24)
  • 2
    • 0027426040 scopus 로고
    • Generalized k-space analysis and correction of motion effects in MR imaging
    • Lauzon M.L., Rutt B.K. Generalized k-space analysis and correction of motion effects in MR imaging. Magn Reson Med. 30:1993;438-446.
    • (1993) Magn Reson Med , vol.30 , pp. 438-446
    • Lauzon, M.L.1    Rutt, B.K.2
  • 3
    • 0029428613 scopus 로고
    • The motion sensitivity of magnetic resonance imaging: A comparison between fourier transform imaging and projection reconstruction
    • Montreal
    • Van de Walle R, Voet T, Lemahieu I. The motion sensitivity of magnetic resonance imaging: A comparison between fourier transform imaging and projection reconstruction. In: Proceedings IEEE EMBC and CMBEC, 17th Conference, Montreal, 1995:457-458.
    • (1995) In: Proceedings IEEE EMBC and CMBEC, 17th Conference , pp. 457-458
    • Van De Walle, R.1    Voet, T.2    Lemahieu, I.3
  • 7
    • 0023836361 scopus 로고
    • Acquisition order and motional artifact reduction in spin warp images
    • Dixon W.T., Brummer M.E., Malko J.A. Acquisition order and motional artifact reduction in spin warp images. Magn Reson Med. 6:1988;74-83.
    • (1988) Magn Reson Med , vol.6 , pp. 74-83
    • Dixon, W.T.1    Brummer, M.E.2    Malko, J.A.3
  • 8
    • 0023217321 scopus 로고
    • Improving MR image quality in the presence of motion using rephasing gradients
    • Haacke E.M., Lenz G.W. Improving MR image quality in the presence of motion using rephasing gradients. Am J Radiol. 148:1987;1251-1258.
    • (1987) Am J Radiol , vol.148 , pp. 1251-1258
    • Haacke, E.M.1    Lenz, G.W.2
  • 9
    • 0025916173 scopus 로고
    • Reduction of flow artifacts in NMR diffusion imaging using view-angle tilted line-integral projection reconstruction
    • Jung K.J., Cho Z.H. Reduction of flow artifacts in NMR diffusion imaging using view-angle tilted line-integral projection reconstruction. Magn Reson Med. 19:1991;349-360.
    • (1991) Magn Reson Med , vol.19 , pp. 349-360
    • Jung, K.J.1    Cho, Z.H.2
  • 10
    • 0026688914 scopus 로고
    • Motion artifact suppression: A review of post-processing techniques
    • Hedley M, Yan H Motion artifact suppression: A review of post-processing techniques. Magn Reson Imaging. 10:1992;627-635.
    • (1992) Magn Reson Imaging , vol.10 , pp. 627-635
    • Hedley, M.1    Yan, H.2
  • 11
    • 0026117505 scopus 로고
    • Motion artifact correction in MRI using generalized projections
    • Hedley M., Yan H., Rosenfeld D. Motion artifact correction in MRI using generalized projections. IEEE Trans Med Imaging. 10:1991;40-46.
    • (1991) IEEE Trans Med Imaging , vol.10 , pp. 40-46
    • Hedley, M.1    Yan, H.2    Rosenfeld, D.3
  • 12
    • 0345143723 scopus 로고
    • An automatic phase correction method in NMRI
    • Lui J., Koenig J.L. An automatic phase correction method in NMRI. J Magn Reson. 86:1990;593-604.
    • (1990) J Magn Reson , vol.86 , pp. 593-604
    • Lui, J.1    Koenig, J.L.2
  • 13
    • 0027531603 scopus 로고
    • Correction of translational motion artifacts in multi-slice spin-echo imaging using self-calibration
    • Zang L.-H., Fielden J., Wilbrink J., Takane A., Koizumi H. Correction of translational motion artifacts in multi-slice spin-echo imaging using self-calibration. Magn Reson Med. 29:1993;327-334.
    • (1993) Magn Reson Med , vol.29 , pp. 327-334
    • Zang, L.-H.1    Fielden, J.2    Wilbrink, J.3    Takane, A.4    Koizumi, H.5
  • 14
    • 0027258745 scopus 로고
    • Use of a projection reconstruction method to decrease motion sensitivity in diffusion-weighted MRI
    • Gmitro A.F., Alexander A.L. Use of a projection reconstruction method to decrease motion sensitivity in diffusion-weighted MRI. Magn Reson Med. 29:1993;835-838.
    • (1993) Magn Reson Med , vol.29 , pp. 835-838
    • Gmitro, A.F.1    Alexander, A.L.2
  • 15
    • 0027093023 scopus 로고
    • Projection reconstruction techniques for reduction of motion effects in MRI
    • Glover G.H., Pauly J.M. Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson Med. 28:1992;275-289.
    • (1992) Magn Reson Med , vol.28 , pp. 275-289
    • Glover, G.H.1    Pauly, J.M.2
  • 16
    • 0022686199 scopus 로고
    • High-speed spiral-scan echo planar NMR imaging
    • Ahn C.B., Kim J.H., Cho Z.H. High-speed spiral-scan echo planar NMR imaging. IEEE Trans Med Imaging. 5(1):1986;2-7.
    • (1986) IEEE Trans Med Imaging , vol.5 , Issue.1 , pp. 2-7
    • Ahn, C.B.1    Kim, J.H.2    Cho, Z.H.3
  • 18
    • 0024453449 scopus 로고
    • Adaptive technique for high-definition MR imaging of moving structures
    • Ehman R.L., Felmlee J.P. Adaptive technique for high-definition MR imaging of moving structures. Radiology. 173:1989;255-263.
    • (1989) Radiology , vol.173 , pp. 255-263
    • Ehman, R.L.1    Felmlee, J.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.