메뉴 건너뛰기




Volumn 17, Issue 2, 1998, Pages 58-63

Sv02 monitoring: Tool for evaluating patient outcomes

Author keywords

Hemodynamics; Monitoring; Oximetry; Physiologic; Sv02

Indexed keywords

OXYGEN;

EID: 0032015918     PISSN: 07304625     EISSN: 15388646     Source Type: Journal    
DOI: 10.1097/00003465-199803000-00001     Document Type: Article
Times cited : (1)

References (11)
  • 1
    • 0027525574 scopus 로고
    • Using mixed venous oxygen saturation data to trend overall oxygenation in card iothoracic surgical patients
    • Pier A. Using mixed venous oxygen saturation data to trend overall oxygenation in card iothoracic surgical patients. Critical Care Nursing Quarterly. 1993;3:72-85.
    • (1993) Critical Care Nursing Quarterly , vol.3 , pp. 72-85
    • Pier, A.1
  • 2
    • 0027548172 scopus 로고
    • Using continuous SVO, to assess oxygen supply/demand balance in the critically ill patient
    • White K. Using continuous SVO, to assess oxygen supply/demand balance in the critically ill patient. AACN Clinical Issues. 1993;1:134-146.
    • (1993) AACN Clinical Issues , vol.1 , pp. 134-146
    • White, K.1
  • 3
  • 4
    • 85026135115 scopus 로고
    • Application and Noninvasive Alternatives. 1st ed. Philadelphia, PA: W.B. Saunders Company
    • Malley W. Clinical Blood Gases: Application and Noninvasive Alternatives. 1st ed. Philadelphia, PA: W.B. Saunders Company; 1990:94-95,284.
    • (1990) Clinical Blood Gases , vol.94-95 , pp. 284
    • Malley, W.1
  • 5
    • 85026140303 scopus 로고
    • Dantzker D., MflC-Intyre N., Bakow E. Comprehensive Respiratory Care. 1st ed. Philadelphia, PA: W. B. Sanders Company
    • Durbin C. Hemodynamic Monitoring, in Dantzker D., MflC-Intyre N., Bakow E. Comprehensive Respiratory Care. 1st ed. Philadelphia, PA: W. B. Sanders Company; 1995:237-238
    • (1995) Hemodynamic Monitoring , pp. 237-238
    • Durbin, C.1
  • 6
    • 0028710304 scopus 로고
    • Evaluating cardiopulmonary instability with continuous monitoring of mixed venous oxygen saturation
    • Henneman E, Gawlinski A. Evaluating cardiopulmonary instability with continuous monitoring of mixed venous oxygen saturation. Critical Care Nursing Clinics of North America. 1994;4: 855-862.
    • (1994) Critical Care Nursing Clinics of North America , vol.4 , pp. 855-862
    • Henneman, E.1    Gawlinski, A.2
  • 7
    • 0038422133 scopus 로고
    • Darovic G; Hemodynamic Monitoring: Invasive and Noninvas-ive Clinical Application. 1st ed. Philadelphia, PA: W.B. Saunders Company;, Chap 11
    • White K. Continuous monitoring of mixed venous oxygen saturation, in Darovic G; Hemodynamic Monitoring: Invasive and Noninvas-ive Clinical Application. 1st ed. Philadelphia, PA: W.B. Saunders Company; 1987;Chap 11.
    • (1987) Continuous Monitoring of Mixed Venous Oxygen Saturation
    • White, K.1
  • 8
    • 0026950483 scopus 로고
    • Osmanski P. Fluctuation in mixed venous oxygen saturation in critically ill medical patients: A pilot study
    • Noll M, Osmanski P. Fluctuation in mixed venous oxygen saturation in critically ill medical patients: A pilot study. American Journal of Critical Care. 1992;3: 102-106.
    • (1992) American Journal of Critical Care , vol.3 , pp. 102-106
    • Noll, M.1
  • 10
    • 0026929941 scopus 로고
    • Hemodynamic monitoring
    • What it tells you and what it doesn’t
    • Christensen B. Hemodynamic monitoring: What it tells you and what it doesn’t, part II. Journal of Post Anesthesia Nursing. 1992;5: 338-343.
    • (1992) Journal of Post Anesthesia Nursing , vol.5 , pp. 338-343
    • Christensen, B.1
  • 11
    • 85026141149 scopus 로고
    • Dantzker D. MacIntyre N. Bakow E,; Comprehensive Respiratory Care. 1st ed. Philadelphia, PA: W.B. Saunders Company;
    • Malloy R, Pierce M. Oxygen therapy, in Dantzker D. MacIntyre N. Bakow E,; Comprehensive Respiratory Care. 1st ed. Philadelphia, PA: W.B. Saunders Company; 1995:506.
    • (1995) Oxygen Therapy , pp. 506
    • Malloy, R.1    Pierce, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.