메뉴 건너뛰기




Volumn 45, Issue 2, 1998, Pages 338-348

Two-dimensional arrays for medical ultrasound using multilayer flexible circuit interconnection

Author keywords

[No Author keywords available]

Indexed keywords

BANDWIDTH; DIELECTRIC MATERIALS; MEDICAL IMAGING; POLYIMIDES; PROBLEM SOLVING; ULTRASONIC IMAGING;

EID: 0032012560     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/58.660144     Document Type: Article
Times cited : (50)

References (23)
  • 1
    • 0029461339 scopus 로고    scopus 로고
    • Limits on the performance of near field phase aberration correction
    • 1995, pp. 1461-1465.
    • W. K. Walker and G. E. Trahey, Limits on the performance of near field phase aberration correction, Proc. IEEE Ultrason. Symp., 1995, pp. 1461-1465.
    • Proc. IEEE Ultrason. Symp.
    • Walker, W.K.1    Trahey, G.E.2
  • 3
    • 0024111013 scopus 로고    scopus 로고
    • Phase aberration correction using signals from point reflectors and diffuse scatters: Basic principles
    • vol. 35, no. 6, pp. 758-767, 1988.
    • S. W. Flax and M. O'Donnell, Phase aberration correction using signals from point reflectors and diffuse scatters: basic principles, IEEE Trans. Ultrason., Ferroelect., Freg. Contr., vol. 35, no. 6, pp. 758-767, 1988.
    • IEEE Trans. Ultrason., Ferroelect., Freg. Contr.
    • Flax, S.W.1    O'Donnell, M.2
  • 4
    • 0025485954 scopus 로고    scopus 로고
    • Experimental results with a real-time adaptive ultrasonic imaging system for viewing through distorting media
    • vol. 37, no. 5, pp. 418-427, 1990.
    • G. E. Trahey, D. Zhao, J. A. Miglin, and S. W. Smith, Experimental results with a real-time adaptive ultrasonic imaging system for viewing through distorting media, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 37, no. 5, pp. 418-427, 1990.
    • IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
    • Trahey, G.E.1    Zhao, D.2    Miglin, J.A.3    Smith, S.W.4
  • 5
    • 0026123398 scopus 로고    scopus 로고
    • A novel method for angle independent ultrasonic imaging of blood flow and tissue motion
    • vol. 38, no. 3, pp. 280-286, 1991.
    • L. N. Bohs and G. E. Trahey, A novel method for angle independent ultrasonic imaging of blood flow and tissue motion, IEEE Trans. Biomed. Eng., vol. 38, no. 3, pp. 280-286, 1991.
    • IEEE Trans. Biomed. Eng.
    • Bohs, L.N.1    Trahey, G.E.2
  • 6
    • 0025577705 scopus 로고    scopus 로고
    • Simulation of B-scan images from two-dimensional transducer arrays
    • 1990, pp. 769-774.
    • D. H. Turnbull, A. T. Kcrr, and F. S. Foster, Simulation of B-scan images from two-dimensional transducer arrays, Proc. IEEE Ultrason. Symp., 1990, pp. 769-774.
    • Proc. IEEE Ultrason. Symp.
    • Turnbull, D.H.1    Kcrr, A.T.2    Foster, F.S.3
  • 7
    • 0028749944 scopus 로고    scopus 로고
    • Optimizing sparse twodimensional transducer arrays using an effective aperture approach, in
    • 1994, pp. 1497-1501.
    • G. R. Lockwood and F. S. Foster, Optimizing sparse twodimensional transducer arrays using an effective aperture approach, in Proc. IEEE Ultrason. Symp., 1994, pp. 1497-1501.
    • Proc. IEEE Ultrason. Symp.
    • Lockwood, G.R.1    Foster, F.S.2
  • 8
    • 0026489652 scopus 로고    scopus 로고
    • Twodimensional array transducers for medical ultrasound
    • vol. 14, pp. 213-233, 1992.
    • S. W. Smith, G. E. Trahey, and O. T. von Ramm, Twodimensional array transducers for medical ultrasound, Ultrason. Imaging, vol. 14, pp. 213-233, 1992.
    • Ultrason. Imaging
    • Smith, S.W.1    Trahey, G.E.2    Von Ramm, O.T.3
  • 11
    • 0027703127 scopus 로고    scopus 로고
    • Two-dimensional array transducers using thick film connection technology
    • vol. 40, no. 6, pp. 727-734, 1993.
    • S. W. Smith and E. D. Light, Two-dimensional array transducers using thick film connection technology, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 40, no. 6, pp. 727-734, 1993.
    • IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
    • Smith, S.W.1    Light, E.D.2
  • 13
    • 77957075096 scopus 로고    scopus 로고
    • Applications of microelectronics and microfabrication to ultra.sound imaging systems
    • 1992, pp. 681-691.
    • A. L. Robinson and J.-H. Mo, Applications of microelectronics and microfabrication to ultra.sound imaging systems, Proc IEEE Ultrason. Symp., 1992, pp. 681-691.
    • Proc IEEE Ultrason. Symp.
    • Robinson, A.L.1    Mo, J.-H.2
  • 14
    • 33747964978 scopus 로고    scopus 로고
    • Two-dimensional array fabrication using flexible circuit technology
    • vol. 17, pp. 59-60, 1995 (abstr.).
    • R. E. Davidsen and S. W. Smith, Two-dimensional array fabrication using flexible circuit technology, Ultrason. Imaging Tissue Characterization, vol. 17, pp. 59-60, 1995 (abstr.).
    • Ultrason. Imaging Tissue Characterization
    • Davidsen, R.E.1    Smith, S.W.2
  • 16
    • 0025434841 scopus 로고    scopus 로고
    • Simulation of piezoelectric devices by two- And threedimensional finite elements
    • vol. 37, no. 3, pp. 233-247, 1990.
    • R. Lerch, Simulation of piezoelectric devices by two- and threedimensional finite elements, IEEE Trans. Ultrason,., Ferroelect., Freq. Contr., vol. 37, no. 3, pp. 233-247, 1990.
    • IEEE Trans. Ultrason,., Ferroelect., Freq. Contr.
    • Lerch, R.1
  • 17
  • 21
    • 0002476583 scopus 로고    scopus 로고
    • A theory for thé radiation pattern of a narrow strip acoustic transducer
    • vol. 37, no. 1, pp. 35-36, 1980.
    • A. R. Selfridge, G. S. Kino, and B. T. Khuri-Yahub, A theory for thé radiation pattern of a narrow strip acoustic transducer, Appl. Phys. Lett., vol. 37, no. 1, pp. 35-36, 1980.
    • Appl. Phys. Lett.
    • Selfridge, A.R.1    Kino, G.S.2    Khuri-Yahub, B.T.3
  • 23
    • 0030369683 scopus 로고    scopus 로고
    • A multiplexed twodimensional array for real-time volumetric and B-mode imaging
    • 1996, pp. 1523-1526.
    • R. E. Davidsen and S. W. Smith, A multiplexed twodimensional array for real-time volumetric and B-mode imaging, Proc. JEEE Ultrason. Symp., 1996, pp. 1523-1526.
    • Proc. JEEE Ultrason. Symp.
    • Davidsen, R.E.1    Smith, S.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.