Assessment of pulmonary mechanics in mechanical ventilation: Effects of imprecise breath detection, phase shift and noise

Author keywords

Airway flow and pressure simulation; Intrinsic PEEP; Mechanical ventilation; Pulmonary mechanics; Total compliance; Total resistance

Indexed keywords

ACOUSTIC NOISE; ALGORITHMS; COMPUTER SIMULATION; LEAST SQUARES APPROXIMATIONS; PHASE SHIFT; RESPIRATORY MECHANICS;

EID: 0032005622     PISSN: 13871307     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (21)
  • 1
    • 0016844194 scopus 로고
    • Optimum end-expiratory airway pressure in patients with acute pulmonary failure
    • Suter PM, Fairley HB, Isenberg MD. Optimum end-expiratory airway pressure in patients with acute pulmonary failure. N Engl J Med 1975; 292: 284-289
    • (1975) N Engl J Med , vol.292 , pp. 284-289
    • Suter, P.M.1    Fairley, H.B.2    Isenberg, M.D.3
  • 2
    • 0021801538 scopus 로고
    • Measurement of static compliance of the total respiratory system in patients with acute respiratory failure during mechanical ventilation. the effect of intrinsic positive end-expiratory pressure
    • Rossi A, Gottfried SB, Zocchi L et al. Measurement of static compliance of the total respiratory system in patients with acute respiratory failure during mechanical ventilation. The effect of intrinsic positive end-expiratory pressure. Am Rev Respir Dis 1985; 131: 672-677
    • (1985) Am Rev Respir Dis , vol.131 , pp. 672-677
    • Rossi, A.1    Gottfried, S.B.2    Zocchi, L.3
  • 3
    • 0028214497 scopus 로고
    • Determination of intrinsic PEEP in mechanically ventilated patients. Validation of a new optional method of the intensive care ventilator EVITA
    • Sydow M, Denecke T, Zinserling J et al. Determination of intrinsic PEEP in mechanically ventilated patients. Validation of a new optional method of the intensive care ventilator EVITA. Anaesthesist 1994; 43: 115-120
    • (1994) Anaesthesist , vol.43 , pp. 115-120
    • Sydow, M.1    Denecke, T.2    Zinserling, J.3
  • 4
    • 0026665958 scopus 로고
    • Intrinsic PEEP and unilateral lung hyperinflation. Pathophysiology and clinical significance
    • Kollef MH, Turner JF. Intrinsic PEEP and unilateral lung hyperinflation. Pathophysiology and clinical significance. Chest 1992; 102: 1220-1224
    • (1992) Chest , vol.102 , pp. 1220-1224
    • Kollef, M.H.1    Turner, J.F.2
  • 5
    • 0027367621 scopus 로고
    • Measurement of respiratory mechanics using the Puritan-Bennett 7200a ventilator
    • Chartrand D, Dionne B, Jodoin C et al. Measurement of respiratory mechanics using the Puritan-Bennett 7200a ventilator. Can J Anaesth 1993; 40: 1076-1083
    • (1993) Can J Anaesth , vol.40 , pp. 1076-1083
    • Chartrand, D.1    Dionne, B.2    Jodoin, C.3
  • 6
    • 0027670341 scopus 로고
    • Comparison of six methods to calculate airway resistance during mechanical ventilation in adults
    • Hess D, Tabor T. Comparison of six methods to calculate airway resistance during mechanical ventilation in adults. J Clin Monit 1993; 9: 275-282
    • (1993) J Clin Monit , vol.9 , pp. 275-282
    • Hess, D.1    Tabor, T.2
  • 7
    • 0028105731 scopus 로고
    • Dynamic hyperinflation and intrinsic PEEP during mechanical ventilation
    • Romand JA, Suter PM. Dynamic hyperinflation and intrinsic PEEP during mechanical ventilation. Eur J Anaesthesiol 1994; 11: 25-28
    • (1994) Eur J Anaesthesiol , vol.11 , pp. 25-28
    • Romand, J.A.1    Suter, P.M.2
  • 8
    • 0027400794 scopus 로고
    • Effects of PEEP on dynamic hyperinflation in patients with airflow limitation
    • Tan IK S, Bhatt SB, Tam YH, Oh TE. Effects of PEEP on dynamic hyperinflation in patients with airflow limitation. Br J Anaesth 1993; 70: 267-272
    • (1993) Br J Anaesth , vol.70 , pp. 267-272
    • Tan, I.K.S.1    Bhatt, S.B.2    Tam, Y.H.3    Oh, T.E.4
  • 9
    • 0019989011 scopus 로고
    • Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction
    • Pepe PE, Marini JJ. Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction. Am Rev Respir Dis 1982; 126: 166-170
    • (1982) Am Rev Respir Dis , vol.126 , pp. 166-170
    • Pepe, P.E.1    Marini, J.J.2
  • 10
    • 0016764744 scopus 로고
    • Monitoring of ventilation and lung mechanics during automatic ventilation. A new device
    • Jonson B, Nordstrom L, Olsson SG, Akerback D. Monitoring of ventilation and lung mechanics during automatic ventilation. A new device. Bull Eur Physiopath Resp 1975; 11: 729-743
    • (1975) Bull Eur Physiopath Resp , vol.11 , pp. 729-743
    • Jonson, B.1    Nordstrom, L.2    Olsson, S.G.3    Akerback, D.4
  • 11
    • 0021969865 scopus 로고
    • Noninvasive determination of respiratory system mechanics during mechanical ventilation for acute respiratory failure
    • Gottfried SB, Rossi A, Higgs BD et al. Noninvasive determination of respiratory system mechanics during mechanical ventilation for acute respiratory failure. Am Rev Respir Dis 1985; 131: 414-420
    • (1985) Am Rev Respir Dis , vol.131 , pp. 414-420
    • Gottfried, S.B.1    Rossi, A.2    Higgs, B.D.3
  • 13
    • 0016167380 scopus 로고
    • Digital computer calculation of human pulmonary mechanics using a least squares fit technique
    • Uhl RR, Lewis FJ. Digital computer calculation of human pulmonary mechanics using a least squares fit technique. Comput Biomed Res 1974; 7: 489-495
    • (1974) Comput Biomed Res , vol.7 , pp. 489-495
    • Uhl, R.R.1    Lewis, F.J.2
  • 14
    • 0026702195 scopus 로고
    • Maneuver-free determination of compliance and resistance in ventilated ARDS patients
    • Guttmann J, Eberhard L, Wolff G et al. Maneuver-free determination of compliance and resistance in ventilated ARDS patients. Chest 1992; 102: 1235-1242
    • (1992) Chest , vol.102 , pp. 1235-1242
    • Guttmann, J.1    Eberhard, L.2    Wolff, G.3
  • 15
    • 0029007208 scopus 로고
    • Respiratory mechanics by least squares fitting in mechanically ventilated patients: Applications during paralysis and during pressure support ventilation
    • Iotti GA, Braschi A, Brunner JX et al. Respiratory mechanics by least squares fitting in mechanically ventilated patients: applications during paralysis and during pressure support ventilation. Intensive Care Med 1995; 21: 406-413
    • (1995) Intensive Care Med , vol.21 , pp. 406-413
    • Iotti, G.A.1    Braschi, A.2    Brunner, J.X.3
  • 16
    • 0026705068 scopus 로고
    • Intrinsic PEEP monitored in the ventilated ARDS patient with a mathematical method
    • Eberhard L, Guttmann J, Wolff G et al. Intrinsic PEEP monitored in the ventilated ARDS patient with a mathematical method. J Appl Physiol 1992; 73: 479-485
    • (1992) J Appl Physiol , vol.73 , pp. 479-485
    • Eberhard, L.1    Guttmann, J.2    Wolff, G.3
  • 17
    • 0029278220 scopus 로고
    • Influence of flow pattern on the parameter estimates of a simple breathing mechanics model
    • Avazolini G, Barbini P, Cappello A, Cevenini G. Influence of flow pattern on the parameter estimates of a simple breathing mechanics model. IEEE Trans Biomed Eng 1995; 42: 394-402
    • (1995) IEEE Trans Biomed Eng , vol.42 , pp. 394-402
    • Avazolini, G.1    Barbini, P.2    Cappello, A.3    Cevenini, G.4
  • 20
    • 0037516142 scopus 로고
    • Respiratory resistance in mechanically ventilated patients: The effects of PEEP
    • Vincent JL, ed., Berlin: Springer
    • Pesenti A, Pelosi P. Respiratory resistance in mechanically ventilated patients: The effects of PEEP. In: Vincent JL, ed., Yearbook of Intensive Care and Emergency Medicine. Berlin: Springer, 1992: 325-330
    • (1992) Yearbook of Intensive Care and Emergency Medicine , pp. 325-330
    • Pesenti, A.1    Pelosi, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.