메뉴 건너뛰기




Volumn 40, Issue 3, 1998, Pages 747-750

Independent technique of verifying high-dose rate (HDR) brachytherapy treatment plans

Author keywords

Brachytherapy; Dosimetry; Radiation therapy; Treatment planning

Indexed keywords

ARTICLE; BRACHYTHERAPY; CANCER; DOSIMETRY; PRIORITY JOURNAL; RADIATION DOSE; TREATMENT PLANNING;

EID: 0032005418     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(97)00851-1     Document Type: Article
Times cited : (5)

References (16)
  • 3
    • 0010614796 scopus 로고
    • Simple and effective verification method for GYN three catheter HDR brachytherapy applications
    • 3. Chen, E. Simple and effective verification method for GYN three catheter HDR brachytherapy applications. (Abstr.) Med. Phys. 22:903; 1995.
    • (1995) Med. Phys. , vol.22 , pp. 903
    • Chen, E.1
  • 4
    • 0010620376 scopus 로고    scopus 로고
    • Dosimetric correlation between HDR and LDR computational algorithms
    • 4. Deore, S.; Fontenla, D.; Vikram B. Dosimetric correlation between HDR and LDR computational algorithms. (Abstr.) Med. Phys. 23:1037; 1996.
    • (1996) Med. Phys. , vol.23 , pp. 1037
    • Deore, S.1    Fontenla, D.2    Vikram, B.3
  • 5
    • 0028321688 scopus 로고
    • Quality assurance of treatment plans for optimized high dose rate brachytherapy-planar implants
    • 5. Ezzell, G. A. Quality assurance of treatment plans for optimized high dose rate brachytherapy-planar implants. Med. Phys. 21:659-661; 1995.
    • (1995) Med. Phys. , vol.21 , pp. 659-661
    • Ezzell, G.A.1
  • 6
    • 0010550167 scopus 로고    scopus 로고
    • Two mathematical equations to verify computer treatment planning outputs for esophageal HDR treatment
    • 6. Khalifeh, A.; Kuwaifi, A.; Edwards, C.; Krueger, J. Two mathematical equations to verify computer treatment planning outputs for esophageal HDR treatment. (Abstr.) Med. Phys. 23:1037; 1996.
    • (1996) Med. Phys. , vol.23 , pp. 1037
    • Khalifeh, A.1    Kuwaifi, A.2    Edwards, C.3    Krueger, J.4
  • 7
    • 0026918255 scopus 로고
    • Verification of treatment plans by mathematical formulas for single catheter HDR brachytherapy
    • 7. Kubo, H. Verification of treatment plans by mathematical formulas for single catheter HDR brachytherapy. Med. Dosm. 17:151-155; 1992.
    • (1992) Med. Dosm. , vol.17 , pp. 151-155
    • Kubo, H.1
  • 8
    • 0000600225 scopus 로고
    • Simple mathematical formulas for quick-checking of single-catheter high dose rate brachytherapy treatment plans
    • 8. Kubo, H.; Chin, R. B. Simple mathematical formulas for quick-checking of single-catheter high dose rate brachytherapy treatment plans. Endocurie Hypertherm. Oncol. 8:165-169; 1992.
    • (1992) Endocurie Hypertherm. Oncol. , vol.8 , pp. 165-169
    • Kubo, H.1    Chin, R.B.2
  • 9
    • 0029804603 scopus 로고    scopus 로고
    • A method for verifying treatment times for simple high-dose-rate endobronchial brachytherapy procedures
    • 9. Miller, A. V.; Davis, M. G.; Horton, J. L. A method for verifying treatment times for simple high-dose-rate endobronchial brachytherapy procedures. Med. Phys. 23:1903-1908; 1996.
    • (1996) Med. Phys. , vol.23 , pp. 1903-1908
    • Miller, A.V.1    Davis, M.G.2    Horton, J.L.3
  • 10
    • 0029374111 scopus 로고
    • High dose rate (hdr) brachytherapy technique: For carcinoma of uterine cervix using nucletron applicators
    • 10. Nair, M. T. K.; Cheng, M. C.; Barker, A.; Rouse, B. S. High dose rate (hdr) brachytherapy technique: for carcinoma of uterine cervix using nucletron applicators. Med. Dosm. 20: 201-207; 1995.
    • (1995) Med. Dosm. , vol.20 , pp. 201-207
    • Nair, M.T.K.1    Cheng, M.C.2    Barker, A.3    Rouse, B.S.4
  • 11
  • 13
    • 0010620602 scopus 로고
    • Ir-192 high dose rate remote afterloading dose calculation verification
    • Abst.
    • 13. Scala, R. Ir-192 High dose rate remote afterloading dose calculation verification. Med. Phys. 22:902 Abst.; 1995.
    • (1995) Med. Phys. , vol.22 , pp. 902
    • Scala, R.1
  • 14
    • 0010619839 scopus 로고
    • Dose verification in HDR remote afterloading
    • Baltimore/Washington 6-8 September 1992. Veenendal, Netherlands: Nucletron International B.V.
    • 14. Young, R. D.; Witbeck, K. A. Dose verification in HDR remote afterloading. In: 7th International brachytherapy working conference, Baltimore/Washington 6-8 September 1992. Veenendal, Netherlands: Nucletron International B.V.; 1992: 277-282.
    • (1992) 7th International Brachytherapy Working Conference , pp. 277-282
    • Young, R.D.1    Witbeck, K.A.2
  • 15
    • 0029092628 scopus 로고    scopus 로고
    • A method to check treatment time calculations in Ir-192 high-dose-rate volume implants
    • 15. Venselaar, J. L. M.; Bierhuizen, H. W. J.; Klop, R. A method to check treatment time calculations in Ir-192 high-dose-rate volume implants. Med. Phys. 22: 1499-1500; 1996.
    • (1996) Med. Phys. , vol.22 , pp. 1499-1500
    • Venselaar, J.L.M.1    Bierhuizen, H.W.J.2    Klop, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.