메뉴 건너뛰기




Volumn 53, Issue 1-2, 1998, Pages 39-47

Improving the removal efficiency of industrial-scale cyclones for particles smaller than five micrometre

Author keywords

Bleed flow; Cyclone; Fine particles; Gas cleaning; Separation efficiency

Indexed keywords

AGGLOMERATION; COMPUTATIONAL FLUID DYNAMICS; DUST COLLECTORS; DUST CONTROL; FLOW PATTERNS; PARTICULATE EMISSIONS; VORTEX FLOW; WALL FLOW;

EID: 0031999404     PISSN: 03017516     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0301-7516(97)00055-0     Document Type: Article
Times cited : (28)

References (4)
  • 1
    • 0022181989 scopus 로고
    • Cyclone collection efficiency: Comparison of experimental results with theoretical predictions
    • Dirgo, J., Leith, D., 1985. Cyclone collection efficiency: comparison of experimental results with theoretical predictions. Aerosol Sci. Technol. 4, 401.
    • (1985) Aerosol Sci. Technol. , vol.4 , pp. 401
    • Dirgo, J.1    Leith, D.2
  • 2
    • 0023993504 scopus 로고
    • Prediction of particle removal in cyclone separators
    • Mothes, R., Löffler, F., 1988. Prediction of particle removal in cyclone separators. Int. Chem. Eng. 28 (2), 231.
    • (1988) Int. Chem. Eng. , vol.28 , Issue.2 , pp. 231
    • Mothes, R.1    Löffler, F.2
  • 3
    • 0042353548 scopus 로고
    • Proposal submitted to Nederlandse Onderneming Voor Energie en Milieu BV (NOVEM), Sept., 1994
    • Plomp, A., van der Laken, R.A., Beumer, M.I.L., 1994. Proposal submitted to Nederlandse Onderneming Voor Energie en Milieu BV (NOVEM), Sept., 1994.
    • (1994)
    • Plomp, A.1    Van Der Laken, R.A.2    Beumer, M.I.L.3
  • 4
    • 0042353549 scopus 로고
    • March
    • Fluent Users Guide, Version 4.3, March, 1995.
    • (1995) Version 4.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.