메뉴 건너뛰기




Volumn 29, Issue 1, 1998, Pages 105-111

Influence of crushing and additive irradiation procedures of EPR dosimetry of tooth enamel

Author keywords

[No Author keywords available]

Indexed keywords

DOSIMETRY; ELECTRON SPIN RESONANCE SPECTROSCOPY; ERROR ANALYSIS; GAMMA RAYS; GRAIN SIZE AND SHAPE; RADIATION EFFECTS;

EID: 0031996161     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4487(97)00205-9     Document Type: Article
Times cited : (57)

References (12)
  • 2
    • 0030294086 scopus 로고    scopus 로고
    • An approach to the assessment of overall uncertainty of determination of dose using ESR technique
    • Chumak, V., Pavlenko, Ju. and Sholom, S. (1996b) An approach to the assessment of overall uncertainty of determination of dose using ESR technique. Appl. Radiat. Isot. 47, 1287-1292.
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 1287-1292
    • Chumak, V.1    Pavlenko, Ju.2    Sholom, S.3
  • 4
    • 0030293961 scopus 로고    scopus 로고
    • Preparation induced errors in EPR dosimetry of enamel: Pre and post crushing sensitivity
    • Haskell, E. H., Hayes, R. B. and Kenner, G. H. (1996) Preparation induced errors in EPR dosimetry of enamel: pre and post crushing sensitivity. Appl. Radiat, Isot. 47, 1305-1310.
    • (1996) Appl. Radiat, Isot. , vol.47 , pp. 1305-1310
    • Haskell, E.H.1    Hayes, R.B.2    Kenner, G.H.3
  • 5
    • 0031122791 scopus 로고    scopus 로고
    • Improved accuracy of EPR dosimetry using a constant rotation goniometer
    • Haskell, E. H., Hayes, R. B. and Kenner, G. H. (1997a) Improved accuracy of EPR dosimetry using a constant rotation goniometer. Radiat. Meas. 27, 325-329.
    • (1997) Radiat. Meas. , vol.27 , pp. 325-329
    • Haskell, E.H.1    Hayes, R.B.2    Kenner, G.H.3
  • 6
    • 0031118856 scopus 로고    scopus 로고
    • An EPR intercomparison using teeth irradiated prior to crushing
    • Haskell, E. H., Kenner, G. H., Hayes, R. B., Sholom, S. and Chumak, V. (1997b) An EPR intercomparison using teeth irradiated prior to crushing. Radiat. Meas. 27, 419-424.
    • (1997) Radiat. Meas. , vol.27 , pp. 419-424
    • Haskell, E.H.1    Kenner, G.H.2    Hayes, R.B.3    Sholom, S.4    Chumak, V.5
  • 8
    • 0014402704 scopus 로고
    • Mechanically induced free radicals in bone
    • Marino, A. A. and Becker, R. O. (1968) Mechanically induced free radicals in bone. Nature 218, 466-467.
    • (1968) Nature , vol.218 , pp. 466-467
    • Marino, A.A.1    Becker, R.O.2
  • 9
    • 0028594895 scopus 로고
    • Transient ESR signals induced by g-irradiation in tooth enamel and in bone
    • Oduwole, A. D. and Sales, K. D. (1994) Transient ESR signals induced by g-irradiation in tooth enamel and in bone. Quat. Geochron. 13, 647-650.
    • (1994) Quat. Geochron. , vol.13 , pp. 647-650
    • Oduwole, A.D.1    Sales, K.D.2
  • 10
    • 0002323486 scopus 로고
    • Effect of mechanically induced background signal on EPR dosimetry of tooth enamel
    • Polyakov, V., Haskell, E., Kenner, G., Huett, G. and Hayes, R. (1995) Effect of mechanically induced background signal on EPR dosimetry of tooth enamel. Radiat. Meas. 24, 249-254.
    • (1995) Radiat. Meas. , vol.24 , pp. 249-254
    • Polyakov, V.1    Haskell, E.2    Kenner, G.3    Huett, G.4    Hayes, R.5
  • 12
    • 0004173919 scopus 로고
    • ESR dosimetry using human tooth enamel
    • (eds Ikeya, M. and Miki, T.), IONICS, Tokyo
    • Tatsumi-Miyajima J. and Okajima S. (1985) ESR dosimetry using human tooth enamel. In: ESR Dating and Dosimetry (eds Ikeya, M. and Miki, T.), pp. 397-405. IONICS, Tokyo.
    • (1985) ESR Dating and Dosimetry , pp. 397-405
    • Tatsumi-Miyajima, J.1    Okajima, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.