-
1
-
-
0018737940
-
Biodegradable polymers for use in surgery: Polyglycolic/polylactic acid homo- and copolymers
-
Gilding, D. K., Reed, A. M. Biodegradable polymers for use in surgery: polyglycolic/polylactic acid homo- and copolymers. J Polymer 20:1459, 1979.
-
(1979)
J Polymer
, vol.20
, pp. 1459
-
-
Gilding, D.K.1
Reed, A.M.2
-
2
-
-
0025334647
-
Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers
-
Bostman, O., Hirvensalo, E., Màkinen, J., and Rokkanen, P. Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. J. Bone Joint Surg. 72B:592-596, 1990.
-
(1990)
J. Bone Joint Surg.
, vol.72 B
, pp. 592-596
-
-
Bostman, O.1
Hirvensalo, E.2
Màkinen, J.3
Rokkanen, P.4
-
3
-
-
0026473093
-
Biodegradable rods versus Kirshner-wire fixation of wrist fractures: A randomized trial
-
Casteleyn, P. P., Handelberg, F., Haeatjens, P. Biodegradable rods versus Kirshner-wire fixation of wrist fractures: a randomized trial. J. Bone Joint Surg. 74B:858-861, 1992.
-
(1992)
J. Bone Joint Surg.
, vol.74 B
, pp. 858-861
-
-
Casteleyn, P.P.1
Handelberg, F.2
Haeatjens, P.3
-
4
-
-
0026760266
-
Biodegradable fixation of ankle fractures: Complications in a prospective study of 25 cases
-
Frøkjær, J. Møller, B. N. Biodegradable fixation of ankle fractures: complications in a prospective study of 25 cases. Acta Orthop. Scand. 63:434-436, 1992.
-
(1992)
Acta Orthop. Scand.
, vol.63
, pp. 434-436
-
-
Frøkjær, J.1
Møller, B.N.2
-
5
-
-
0026847648
-
Effectiveness of absorbable fixation devices in Austin bunionectomies
-
Gerbert, J. Effectiveness of absorbable fixation devices in Austin bunionectomies. J. Am. Podiatr. Med. Assoc. 82:189-195, 1992.
-
(1992)
J. Am. Podiatr. Med. Assoc.
, vol.82
, pp. 189-195
-
-
Gerbert, J.1
-
6
-
-
0028566614
-
Foreign body reactions to absorbable implant fixation of osteotomies
-
Miketa, J. P., Prigoff, M. M. Foreign body reactions to absorbable implant fixation of osteotomies. J. Foot Ankle Surg. 33:623-627, 1994.
-
(1994)
J. Foot Ankle Surg.
, vol.33
, pp. 623-627
-
-
Miketa, J.P.1
Prigoff, M.M.2
-
7
-
-
0027052802
-
Synovitis of the knee after intraarticular fracture fixation with biofix: Report of two cases
-
Barford, G., Svendsen, R. N. Synovitis of the knee after intraarticular fracture fixation with biofix: report of two cases. Acta Orthop. Scand. 63:680-681, 1992.
-
(1992)
Acta Orthop. Scand.
, vol.63
, pp. 680-681
-
-
Barford, G.1
Svendsen, R.N.2
-
8
-
-
0026518970
-
Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures
-
Böstman, O. Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures. Clin. Orthop. 278:193-199, 1990.
-
(1990)
Clin. Orthop.
, vol.278
, pp. 193-199
-
-
Böstman, O.1
-
9
-
-
0026513175
-
Severe aseptic synovitis of the knee after biodegradable internal fixation
-
Fridén, T., Rydholm, U. Severe aseptic synovitis of the knee after biodegradable internal fixation. Acta Orthop. Scand. 63:94-97, 1992.
-
(1992)
Acta Orthop. Scand.
, vol.63
, pp. 94-97
-
-
Fridén, T.1
Rydholm, U.2
-
10
-
-
0027571103
-
Current concepts in bone healing: Review of the literature
-
Greenbaum, M. A., Kanat, I. O. Current concepts in bone healing: review of the literature. J. Am. Podiatr. Med. Assoc. 83:123-129, 1993.
-
(1993)
J. Am. Podiatr. Med. Assoc.
, vol.83
, pp. 123-129
-
-
Greenbaum, M.A.1
Kanat, I.O.2
-
11
-
-
0027231664
-
Complications with the use of bioabsorbable pins in the foot
-
Parks, R. M., Nelson, G. Complications with the use of bioabsorbable pins in the foot. J. Foot Ankle Surg. 32:153-161, 1993.
-
(1993)
J. Foot Ankle Surg.
, vol.32
, pp. 153-161
-
-
Parks, R.M.1
Nelson, G.2
-
12
-
-
6844229330
-
Microhardness determination and histological tests on bone screws made of polydioxanone (PDS) in animal experiments
-
Gay, B., Bucher, H., Romen, W., Brush, H. P., Dusel, W., Gutzeit, B. Microhardness determination and histological tests on bone screws made of polydioxanone (PDS) in animal experiments. Biomaterialien und Nahtmaterial pp. 252-256, 1984.
-
(1984)
Biomaterialien und Nahtmaterial
, pp. 252-256
-
-
Gay, B.1
Bucher, H.2
Romen, W.3
Brush, H.P.4
Dusel, W.5
Gutzeit, B.6
-
13
-
-
0021791943
-
Refixation osteochondraler fragmente durch resorbierbare kunststoffstifte
-
Greve, H., Holste, J. Refixation osteochondraler fragmente durch resorbierbare kunststoffstifte. Akt Traumatol. 15:145-149, 1985.
-
(1985)
Akt Traumatol.
, vol.15
, pp. 145-149
-
-
Greve, H.1
Holste, J.2
-
14
-
-
0028214104
-
Absorbable fixation of first ray osteotomies
-
Hetherington, V. J., Shields, S. L. Wilhelm, K. R. Laporta, D. M., Nicklas, B. J. Absorbable fixation of first ray osteotomies. J. Foot Ankle Surg. 33:290-294, 1994.
-
(1994)
J. Foot Ankle Surg.
, vol.33
, pp. 290-294
-
-
Hetherington, V.J.1
Shields, S.L.2
Wilhelm, K.R.3
Laporta, D.M.4
Nicklas, B.J.5
-
15
-
-
0027308705
-
Suitability of biodegradable polydioxanone materials for the internal fixation of fractures
-
Papagelopoulos, P. J., Giannarakos, D. G., Lyritis, G. P. Suitability of biodegradable polydioxanone materials for the internal fixation of fractures. Orthop. Rev. 5:585-593, 1993.
-
(1993)
Orthop. Rev.
, vol.5
, pp. 585-593
-
-
Papagelopoulos, P.J.1
Giannarakos, D.G.2
Lyritis, G.P.3
-
16
-
-
0019439175
-
Polydioxanone (PDS), a novel monofilament synthetic absorbable suture
-
Ray, J. A., Doddi, N., Regula, D., Williams, J. A., Melveger, A. Polydioxanone (PDS), a novel monofilament synthetic absorbable suture. Surg. Gynecol. Obstet. 153:497-507, 1981.
-
(1981)
Surg. Gynecol. Obstet.
, vol.153
, pp. 497-507
-
-
Ray, J.A.1
Doddi, N.2
Regula, D.3
Williams, J.A.4
Melveger, A.5
-
17
-
-
0026587974
-
Resorbable polyesters: Composition, properties, applications
-
Amecke, B., Bendix, D., Entenmann, G. Resorbable polyesters: composition, properties, applications. Clin. Mat. 10:47-50, 1992.
-
(1992)
Clin. Mat.
, vol.10
, pp. 47-50
-
-
Amecke, B.1
Bendix, D.2
Entenmann, G.3
-
18
-
-
0029796079
-
Biodegradable pins versus Kirschner wires in hand surgery
-
Jensen, C. H, Jensen, C. M. Biodegradable pins versus Kirschner wires in hand surgery. J. Hand Surg. 21B:507-510, 1996.
-
(1996)
J. Hand Surg.
, vol.21 B
, pp. 507-510
-
-
Jensen, C.H.1
Jensen, C.M.2
-
19
-
-
0030207155
-
Foreign-body reaction to absorbable fixation devices
-
Frederick, J., Hulst, T. J., Sundareson, A. S. Foreign-body reaction to absorbable fixation devices. Letter to the Editor, J. Am. Podiatr. Med. Assoc. 86:396-398, 1996.
-
(1996)
J. Am. Podiatr. Med. Assoc.
, vol.86
, pp. 396-398
-
-
Frederick, J.1
Hulst, T.J.2
Sundareson, A.S.3
-
20
-
-
0029147153
-
Orthosorb: A case of foreign-body reaction
-
Kalla, T. P., Janzen, D. L. Orthosorb: a case of foreign-body reaction. J. Foot Ankle Surg. 34:366-370, 1995
-
(1995)
J. Foot Ankle Surg.
, vol.34
, pp. 366-370
-
-
Kalla, T.P.1
Janzen, D.L.2
-
21
-
-
0025961327
-
Ultra-high-strength absorbable self-reinforced polyglycolide (SR-PGA) composite rods for internal fixation of bone fractures: In vitro and in vivo study
-
Törmalä, P., Vasenius, J., Vainionpää, S., Laiho, J., Pohjonen, T., Rokkanen, P. Ultra-high-strength absorbable self-reinforced polyglycolide (SR-PGA) composite rods for internal fixation of bone fractures: in vitro and in vivo study. J. Biomed. Mater. Res. 25:1-22, 1991.
-
(1991)
J. Biomed. Mater. Res.
, vol.25
, pp. 1-22
-
-
Törmalä, P.1
Vasenius, J.2
Vainionpää, S.3
Laiho, J.4
Pohjonen, T.5
Rokkanen, P.6
-
22
-
-
84947355490
-
The effect of site of implantation and animal age on properties of polydioxanone pins
-
Bhatia, S., Shalaby S. W., Powers, D. L., Lancaster, R. L., Ferguson, R. L. The effect of site of implantation and animal age on properties of polydioxanone pins. J. Biomater. Sci. Polymer Edn. 6:435-446, 1994.
-
(1994)
J. Biomater. Sci. Polymer Edn.
, vol.6
, pp. 435-446
-
-
Bhatia, S.1
Shalaby, S.W.2
Powers, D.L.3
Lancaster, R.L.4
Ferguson, R.L.5
-
23
-
-
0025969466
-
Fixation of the Austin osteotomy with bioresorbable pins
-
Brunetti, V. A., Trepal, M. J., Jules, K. T. Fixation of the Austin osteotomy with bioresorbable pins. J. Foot Surg. 30:56-65, 1991.
-
(1991)
J. Foot Surg.
, vol.30
, pp. 56-65
-
-
Brunetti, V.A.1
Trepal, M.J.2
Jules, K.T.3
-
24
-
-
0027480519
-
L-osteotomy with absorbable fixation for correction of tailor's bunion
-
Friend, G., Grace, K., Stone, H. A. L-osteotomy with absorbable fixation for correction of tailor's bunion. J. Foot Ankle Surg., 32:14-19, 1993.
-
(1993)
J. Foot Ankle Surg.
, vol.32
, pp. 14-19
-
-
Friend, G.1
Grace, K.2
Stone, H.A.3
-
25
-
-
0025100335
-
Absorbable pin: A new method of fixation for digital arthrodesis
-
Patton, G. W., Shaffer, M. W., Kostakos, D. P. Absorbable pin: a new method of fixation for digital arthrodesis. J. Foot Surg. 29:122-127, 1990.
-
(1990)
J. Foot Surg.
, vol.29
, pp. 122-127
-
-
Patton, G.W.1
Shaffer, M.W.2
Kostakos, D.P.3
|