메뉴 건너뛰기




Volumn 91, Issue 4, 1998, Pages 389-395

Comparison of echocardiographic automatic border detection and magnetic resonance imaging. Measurements of the left ventricle in normal subjects;Comparaison des mesures ventriculaires gauches par echocardiographie en quantification acoustique et par imagerie magnetique nucleaire chez le sujet normal

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANALYTICAL ERROR; ARTICLE; AUTOMATION; CLINICAL PRACTICE; CONTROLLED STUDY; ECHOCARDIOGRAPHY; HEART LEFT VENTRICLE FUNCTION; HUMAN; INTERMETHOD COMPARISON; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; OBSERVER VARIATION;

EID: 0031981135     PISSN: 00039683     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (16)
  • 1
    • 0026632428 scopus 로고
    • Estimation of left ventricular cavity area with an on-line, semiautomated echocardiographic edge detection system
    • Vandenberg BF, Rath LS, Styhlmuller P, Melton HE Jr, Skorton DJ. Estimation of left ventricular cavity area with an on-line, semiautomated echocardiographic edge detection system. Circulation 1992 ; 86 : 159-66.
    • (1992) Circulation , vol.86 , pp. 159-166
    • Vandenberg, B.F.1    Rath, L.S.2    Styhlmuller, P.3    Melton Jr., H.E.4    Skorton, D.J.5
  • 2
    • 0027971522 scopus 로고
    • Echocardiographic on line volumetry using acoustic quantification-comparison with manual echocardiographic analysis and cineventriculography
    • Epperlein S, Wittlich N, Mohr-Kahaly S, Erbel R, Meyer J. Echocardiographic on line volumetry using acoustic quantification-comparison with manual echocardiographic analysis and cineventriculography. Z Kardiol 1994 ; 83 : 658-65.
    • (1994) Z Kardiol , vol.83 , pp. 658-665
    • Epperlein, S.1    Wittlich, N.2    Mohr-Kahaly, S.3    Erbel, R.4    Meyer, J.5
  • 3
    • 0028067136 scopus 로고
    • Echocardiography online quantification of left and right ventricular function by automatic boundary detection : Reference values and reproducibility in healthy probands
    • Hausmann B, Hach H, Voigt B, Simon R. Echocardiography online quantification of left and right ventricular function by automatic boundary detection : reference values and reproducibility in healthy probands. Z Kardiol 1994 ; 83 : 556-61.
    • (1994) Z Kardiol , vol.83 , pp. 556-561
    • Hausmann, B.1    Hach, H.2    Voigt, B.3    Simon, R.4
  • 4
    • 0028072075 scopus 로고
    • Determination of cardiac output using acoustic quantification in critically ill patients
    • Tardif JC, Cao QL, Pandian NG, Esakof DD, Pollard H. Determination of cardiac output using acoustic quantification in critically ill patients. Am J Cardiol 1994 ; 74 : 810-3.
    • (1994) Am J Cardiol , vol.74 , pp. 810-813
    • Tardif, J.C.1    Cao, Q.L.2    Pandian, N.G.3    Esakof, D.D.4    Pollard, H.5
  • 5
    • 0028453657 scopus 로고
    • Echocardiographic study of left ventricular function using automated border detection in normal subjects
    • Ferrini D, Galvani M, Catapano O, Ottani F, Rusticali F. Echocardiographic study of left ventricular function using automated border detection in normal subjects. G Ital Cardiol 1994 ; 24 : 723-31.
    • (1994) G Ital Cardiol , vol.24 , pp. 723-731
    • Ferrini, D.1    Galvani, M.2    Catapano, O.3    Ottani, F.4    Rusticali, F.5
  • 6
    • 0028147536 scopus 로고
    • Quantification of left ventricular function with an automated border detection system and comparison with radionuclide ventriculography
    • Lindower PD, Rath L, Preslar J, Burns TL, Rezai K, Vandenberg BF. Quantification of left ventricular function with an automated border detection system and comparison with radionuclide ventriculography. Am J Cardiol 1994 ; 73 : 195-9.
    • (1994) Am J Cardiol , vol.73 , pp. 195-199
    • Lindower, P.D.1    Rath, L.2    Preslar, J.3    Burns, T.L.4    Rezai, K.5    Vandenberg, B.F.6
  • 7
    • 0028152519 scopus 로고
    • Measurement of left ventricular ejection fraction by acoustic quantification and comparison with radionuclide angiography
    • Yvorchuk KJ, Davies RA, Chan KL. Measurement of left ventricular ejection fraction by acoustic quantification and comparison with radionuclide angiography. Am J Cardiol 1994 ; 74 : 1052-6.
    • (1994) Am J Cardiol , vol.74 , pp. 1052-1056
    • Yvorchuk, K.J.1    Davies, R.A.2    Chan, K.L.3
  • 8
    • 0029012867 scopus 로고
    • Echocardiographic assessment of systolic and diastolic left ventricular function using an automatic boundary detection system. Correlation with established invasive and non invasive parameters
    • Michalis LK, Thomas MR, Jewitt DE, Monaghan MJ. Echocardiographic assessment of systolic and diastolic left ventricular function using an automatic boundary detection system. Correlation with established invasive and non invasive parameters. Int J Card Imaging 1995 ; 11 : 71-80.
    • (1995) Int J Card Imaging , vol.11 , pp. 71-80
    • Michalis, L.K.1    Thomas, M.R.2    Jewitt, D.E.3    Monaghan, M.J.4
  • 9
    • 0029977284 scopus 로고    scopus 로고
    • Estimation des volumes et de la fraction d'éjection ventriculaires gauches par quantification acoustique dans l'infarctus du myocarde
    • Jennesseaux C, Metz D, Maillier B et al. Estimation des volumes et de la fraction d'éjection ventriculaires gauches par quantification acoustique dans l'infarctus du myocarde. Arch Mal Cœur 1996 ; 89 : 843-9.
    • (1996) Arch Mal Cœur , vol.89 , pp. 843-849
    • Jennesseaux, C.1    Metz, D.2    Maillier, B.3
  • 10
    • 0027236589 scopus 로고
    • Ultrasonic backscatter system for automated on-line endocardial boundary detection : Evaluation by ultrafast computed tomography
    • Marcus RH, Bednarz J, Coulden R, Shroff S, Lipton M, Lang RM. Ultrasonic backscatter system for automated on-line endocardial boundary detection : evaluation by ultrafast computed tomography. J Am Coll Cardiol 1993 ; 22 : 839-47.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 839-847
    • Marcus, R.H.1    Bednarz, J.2    Coulden, R.3    Shroff, S.4    Lipton, M.5    Lang, R.M.6
  • 11
    • 0027692535 scopus 로고
    • Left ventricular volume calculation with integrated backscatter from echocardiography
    • Stewart WJ, Rodkey SM, Gunawardena S. Left ventricular volume calculation with integrated backscatter from echocardiography. J Am Soc Echocardiogr 1993 ; 6 : 553-63.
    • (1993) J Am Soc Echocardiogr , vol.6 , pp. 553-563
    • Stewart, W.J.1    Rodkey, S.M.2    Gunawardena, S.3
  • 12
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986 ; 2 : 307-10.
    • (1986) Lancet , vol.2 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 0023219810 scopus 로고
    • Left ventricular endosystolic volume as the major determinant of survival after recovery from myocardial infarction
    • White HD, Norris RM, Brown MA, Brandt PW, Whitlock RM, Wild CJ. Left ventricular endosystolic volume as the major determinant of survival after recovery from myocardial infarction. Circulation 1987 ; 76 : 44-51.
    • (1987) Circulation , vol.76 , pp. 44-51
    • White, H.D.1    Norris, R.M.2    Brown, M.A.3    Brandt, P.W.4    Whitlock, R.M.5    Wild, C.J.6
  • 14
    • 0028137045 scopus 로고
    • On-line quantification of left ventricular volumes and ejection fraction by automated backscatter imaging-assisted boundary detection : Comparison with contrat cineventriculography
    • Vanoverschelde JL, Hanet C, Wijns W, Detry JM. On-line quantification of left ventricular volumes and ejection fraction by automated backscatter imaging-assisted boundary detection : comparison with contrat cineventriculography. Am J Cardiol 1994 ; 74 : 633-5.
    • (1994) Am J Cardiol , vol.74 , pp. 633-635
    • Vanoverschelde, J.L.1    Hanet, C.2    Wijns, W.3    Detry, J.M.4
  • 15
    • 0029285192 scopus 로고
    • Accuracy and clinical applicability of the echocardiographic automated endocardial boundary detection system : Correlation and bias analysis
    • Gonzalez-Torrecilla E, Garcia-Fernandez MA, San-Roman D et al. Accuracy and clinical applicability of the echocardiographic automated endocardial boundary detection system : correlation and bias analysis. Rev Esp Cardiol 1995 ; 48 : 235-44.
    • (1995) Rev Esp Cardiol , vol.48 , pp. 235-244
    • Gonzalez-Torrecilla, E.1    Garcia-Fernandez, M.A.2    San-Roman, D.3
  • 16
    • 7144249445 scopus 로고
    • Cyclic variation of integrated backscatter of the myocardium parallels myocardial thickening
    • Leung YD, Grimm R, Morehead AJ. Cyclic variation of integrated backscatter of the myocardium parallels myocardial thickening (abstract). Circulation 1994 ; 90 : 8278.
    • (1994) Circulation , vol.90 , pp. 8278
    • Leung, Y.D.1    Grimm, R.2    Morehead, A.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.