메뉴 건너뛰기




Volumn 15, Issue 1, 1998, Pages 55-59

Intraoperative laser Doppler flowmetry: A predictor of ischemic injury in acute mesenteric infarction

Author keywords

Flowmetry; Intestinal ischemia; Laser; Mesenteric infarction; Microcirculation

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; CLINICAL ARTICLE; FEMALE; HUMAN; HUMAN TISSUE; INTESTINE BLOOD FLOW; INTESTINE INFARCTION; INTESTINE ISCHEMIA; INTESTINE RESECTION; LAPAROTOMY; LASER DOPPLER FLOWMETRY; MALE; MORTALITY; PERIOPERATIVE PERIOD; SECOND LOOK SURGERY; SMALL INTESTINE; SUPERIOR MESENTERIC ARTERY; TIME;

EID: 0031975649     PISSN: 02534886     EISSN: None     Source Type: Journal    
DOI: 10.1159/000018587     Document Type: Article
Times cited : (25)

References (21)
  • 1
    • 0027563417 scopus 로고
    • Acute mesenteric ischemia: Pathophysiology, diagnosis and treatment
    • Benjamin E, Oropello JM, Iberti TI: Acute mesenteric ischemia: Pathophysiology, diagnosis and treatment. Dis Mon 1993;39:131-210.
    • (1993) Dis Mon , vol.39 , pp. 131-210
    • Benjamin, E.1    Oropello, J.M.2    Iberti, T.I.3
  • 4
    • 0027254802 scopus 로고
    • Acute mesenteric ischemia
    • Stoney RJ, Cunningham CG: Acute mesenteric ischemia. Surgery 1993;114:489-490.
    • (1993) Surgery , vol.114 , pp. 489-490
    • Stoney, R.J.1    Cunningham, C.G.2
  • 5
    • 0016706729 scopus 로고
    • Prediction of intestinal viability using Doppler ultrasound techniques
    • Wright CB, Hobson RW: Prediction of intestinal viability using Doppler ultrasound techniques. Am J Surg 1975;129:642-645.
    • (1975) Am J Surg , vol.129 , pp. 642-645
    • Wright, C.B.1    Hobson, R.W.2
  • 6
    • 0016053463 scopus 로고
    • Prediction of the viability of revascularized intestine with radioactive microsphere
    • Ziarns CK, Skinner DB, Rhodes BA, James AE: Prediction of the viability of revascularized intestine with radioactive microsphere. Surg Gynecol Obstet 1974;138:576-580.
    • (1974) Surg Gynecol Obstet , vol.138 , pp. 576-580
    • Ziarns, C.K.1    Skinner, D.B.2    Rhodes, B.A.3    James, A.E.4
  • 8
    • 0027971590 scopus 로고
    • Serum D(-)-lactate levels as an aid to diagnosing acute intestinal ischemia
    • Murray MJ, Gonze MD, Nowak LR, Cobb CF: Serum D(-)-lactate levels as an aid to diagnosing acute intestinal ischemia. Am J Surg 1994; 167:575-578.
    • (1994) Am J Surg , vol.167 , pp. 575-578
    • Murray, M.J.1    Gonze, M.D.2    Nowak, L.R.3    Cobb, C.F.4
  • 9
    • 17144445363 scopus 로고
    • Continuous measurements of intestinal mucosal blood flow by laser Doppler velocimetry
    • Shepard AP, Riedel GL: Continuous measurements of intestinal mucosal blood flow by laser Doppler velocimetry. Am J Physiol 1982;242: G668-G672.
    • (1982) Am J Physiol , vol.242
    • Shepard, A.P.1    Riedel, G.L.2
  • 10
    • 0023637985 scopus 로고
    • Tissue penetration and measuring depth of laser Doppler flowmetry in the gastrointestinal application
    • Johansson K, Ahn H, Lindhagen J, Lundgren O: Tissue penetration and measuring depth of laser Doppler flowmetry in the gastrointestinal application. Scand J Gastroenterol 1987;22: 1081-1088.
    • (1987) Scand J Gastroenterol , vol.22 , pp. 1081-1088
    • Johansson, K.1    Ahn, H.2    Lindhagen, J.3    Lundgren, O.4
  • 11
    • 0019351823 scopus 로고
    • Reliable intraoperative prediction of intestinal viability using a fluorescent indicator
    • Marfuggi RA, Greenspan M: Reliable intraoperative prediction of intestinal viability using a fluorescent indicator. Surg Gynecol Obstet 1981;152:33-35.
    • (1981) Surg Gynecol Obstet , vol.152 , pp. 33-35
    • Marfuggi, R.A.1    Greenspan, M.2
  • 12
    • 0019225916 scopus 로고
    • Evaluation of a laser Doppler flowmeter for measurement of tissue blood flow
    • Nilsson GE, Tenland T, Öberg PA: Evaluation of a laser Doppler flowmeter for measurement of tissue blood flow. IEEE Trans Biomed Eng 1980;27:597-604.
    • (1980) IEEE Trans Biomed Eng , vol.27 , pp. 597-604
    • Nilsson, G.E.1    Tenland, T.2    Öberg, P.A.3
  • 13
    • 0022531660 scopus 로고
    • Measurement of colonic blood flow with laser Doppler flowmetry
    • Ahn H, Lindhagen J, Lundgren O: Measurement of colonic blood flow with laser Doppler flowmetry. Scand J Gastroenterol 1986;21: 871-880.
    • (1986) Scand J Gastroenterol , vol.21 , pp. 871-880
    • Ahn, H.1    Lindhagen, J.2    Lundgren, O.3
  • 14
    • 0018620433 scopus 로고
    • Assessment of small intestinal recovery from ischemic injury after segmental arterial, venous and arterovenous occlusion
    • Bulkley GB, Wheaton LG, Strandberg JD, Zuidema GD: Assessment of small intestinal recovery from ischemic injury after segmental arterial, venous and arterovenous occlusion. Surg Forum 1989;30:210-213.
    • (1989) Surg Forum , vol.30 , pp. 210-213
    • Bulkley, G.B.1    Wheaton, L.G.2    Strandberg, J.D.3    Zuidema, G.D.4
  • 16
    • 0027194682 scopus 로고
    • Laser Doppler flux and tissue oxygen tension as indicators of colonie perfusion in pigs
    • Krohg-Sorensen K, Line PD, Kvernebo K: Laser Doppler flux and tissue oxygen tension as indicators of colonie perfusion in pigs. Eur J Surg 1993;159:293-299.
    • (1993) Eur J Surg , vol.159 , pp. 293-299
    • Krohg-Sorensen, K.1    Line, P.D.2    Kvernebo, K.3
  • 17
    • 0029981212 scopus 로고    scopus 로고
    • Gastric microcirculatory changes during gastric tube formation: Assessment with laser Doppler flowmetry
    • Schilling MK, Redaelli CA, Maurer C, Friess H, Büchler MW: Gastric microcirculatory changes during gastric tube formation: Assessment with laser Doppler flowmetry. J Surg Res 1996;62:125-129.
    • (1996) J Surg Res , vol.62 , pp. 125-129
    • Schilling, M.K.1    Redaelli, C.A.2    Maurer, C.3    Friess, H.4    Büchler, M.W.5
  • 18
    • 0026734581 scopus 로고
    • Differential alteration in microvascular perfusion in various organs during early and late sepsis
    • Wang P, Zhou M, Rana MW, Ba ZF, Chaudry IH: Differential alteration in microvascular perfusion in various organs during early and late sepsis. Am J Physiol 1994;263:G38-G43.
    • (1994) Am J Physiol , vol.263
    • Wang, P.1    Zhou, M.2    Rana, M.W.3    Ba, Z.F.4    Chaudry, I.H.5
  • 19
    • 0025369971 scopus 로고
    • The role of second look procedures in improving survival time for patients with mesenteric venous thrombosis
    • Levy PJ, Krausz MM, Manny J: The role of second look procedures in improving survival time for patients with mesenteric venous thrombosis. Surg Gynecol Obstet 1990;170: 287-291.
    • (1990) Surg Gynecol Obstet , vol.170 , pp. 287-291
    • Levy, P.J.1    Krausz, M.M.2    Manny, J.3
  • 20
    • 0023611755 scopus 로고
    • The rationale for second-look operation in mesenteric vessel occlusion with uncertain intestinal viability at preliminary surgery
    • Lindblad B, Hakansson H: The rationale for second-look operation in mesenteric vessel occlusion with uncertain intestinal viability at preliminary surgery. Acta Chir Scand 1987; 157:531-533.
    • (1987) Acta Chir Scand , vol.157 , pp. 531-533
    • Lindblad, B.1    Hakansson, H.2
  • 21
    • 0028091419 scopus 로고
    • 'Secondlook' laparoscopy in the management of acute mesenteric ischaemia
    • MacSweeney ST, Postlethwaite JC: 'Secondlook' laparoscopy in the management of acute mesenteric ischaemia. Br J Surg 1994;81:90.
    • (1994) Br J Surg , vol.81 , pp. 90
    • MacSweeney, S.T.1    Postlethwaite, J.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.