메뉴 건너뛰기




Volumn 74, Issue 1, 1998, Pages 38-47

Neutron fluence and energy spectra around the Varian Clinac 2100C/2300C medical accelerator

Author keywords

Accelerators; Monte Carlo; Neutrons; Shielding

Indexed keywords

ARTICLE; COMPUTER SIMULATION; ELECTRON ACCELERATOR; ENERGY; NEUTRON; PRIORITY JOURNAL;

EID: 0031974030     PISSN: 00179078     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004032-199801000-00005     Document Type: Article
Times cited : (89)

References (20)
  • 3
    • 0011289394 scopus 로고
    • Energy and spatial dependence of neutron fluxes in radiotherapy rooms for a simple dose estimate method
    • Agosteo, S.; Froglio Para, A. Energy and spatial dependence of neutron fluxes in radiotherapy rooms for a simple dose estimate method. Nucl. Inst. Meth. Phys. Res. B 93:362-369; 1994.
    • (1994) Nucl. Inst. Meth. Phys. Res. B , vol.93 , pp. 362-369
    • Agosteo, S.1    Froglio Para, A.2
  • 8
    • 0020068891 scopus 로고
    • Unwanted photon and neutron radiation resulting from collimated photon beams interacting with the body of radiotherapy patients
    • Ing, H.; Nelson. W. R.; Shore, R. A. Unwanted photon and neutron radiation resulting from collimated photon beams interacting with the body of radiotherapy patients. Med. Phys. 9:27-33; 1982.
    • (1982) Med. Phys. , vol.9 , pp. 27-33
    • Ing, H.1    Nelson, W.R.2    Shore, R.A.3
  • 9
    • 0022403355 scopus 로고
    • Neutron energies in medical electron accelerator rooms
    • LaRiviere, P. D. Neutron energies in medical electron accelerator rooms. Med. Phys. 12:769-775; 1985.
    • (1985) Med. Phys. , vol.12 , pp. 769-775
    • LaRiviere, P.D.1
  • 10
    • 0030977691 scopus 로고    scopus 로고
    • Calculations of the giant-dipole-resonance photoneutrons using a coupled EGS4-MORSE code
    • Liu, J. C.; Nelson, W. R.; Kase, K. R.; Mao, X. S. Calculations of the giant-dipole-resonance photoneutrons using a coupled EGS4-MORSE code. Radiat. Prot. Dosim. 70:49-54; 1997.
    • (1997) Radiat. Prot. Dosim. , vol.70 , pp. 49-54
    • Liu, J.C.1    Nelson, W.R.2    Kase, K.R.3    Mao, X.S.4
  • 11
    • 0030067139 scopus 로고    scopus 로고
    • Giant dipole resonance neutron yields produced by electrons as a function of target material and thickness
    • Mao, X.; Kase, K. R.; Nelson, W. R. Giant dipole resonance neutron yields produced by electrons as a function of target material and thickness. Health Phys. 70:207-214; 1996.
    • (1996) Health Phys. , vol.70 , pp. 207-214
    • Mao, X.1    Kase, K.R.2    Nelson, W.R.3
  • 12
    • 0030951805 scopus 로고    scopus 로고
    • Neutron sources in the Varian Clinac 2100C/ 2300C medical accelerator calculated by Monte Carlo
    • Mao, X.; Kase, K. R.; Liu, J. C.; Nelson, W. R.; Kleck, J. H.; Johnsen, S. Neutron sources in the Varian Clinac 2100C/ 2300C medical accelerator calculated by Monte Carlo. Health Phys. 72:523-528; 1997.
    • (1997) Health Phys. , vol.72 , pp. 523-528
    • Mao, X.1    Kase, K.R.2    Liu, J.C.3    Nelson, W.R.4    Kleck, J.H.5    Johnsen, S.6
  • 13
    • 0026458585 scopus 로고
    • Photoneutron fields in medical accelerator rooms with primary barriers constructed of concrete and metals
    • McGinley, P. H. Photoneutron fields in medical accelerator rooms with primary barriers constructed of concrete and metals. Health Phys. 63:698-701; 1992.
    • (1992) Health Phys. , vol.63 , pp. 698-701
    • McGinley, P.H.1
  • 14
    • 0021266808 scopus 로고
    • Neutrons from high-energy x-ray medical accelerators: An estimate of risk to the radiotherapy patient
    • Nath, R.; Epp, E. R.; Laughlin, J. S.; Swanson, W. P.; Bond, V. P. Neutrons from high-energy x-ray medical accelerators: An estimate of risk to the radiotherapy patient. Med. Phys. 11:231-241; 1984.
    • (1984) Med. Phys. , vol.11 , pp. 231-241
    • Nath, R.1    Epp, E.R.2    Laughlin, J.S.3    Swanson, W.P.4    Bond, V.P.5
  • 15
    • 0003511916 scopus 로고
    • Report No. 79. Bethesda, MD: National Council on Radiation Protection and Measurements
    • National Council on Radiation Protection and Measurements. Neutron contamination from medical electron accelerators, Report No. 79. Bethesda, MD: National Council on Radiation Protection and Measurements; 1984.
    • (1984) Neutron Contamination from Medical Electron Accelerators
  • 18
  • 19
    • 0026022572 scopus 로고
    • Neutron measurements around medical electron accelerators by active and passive detection techniques
    • Tosi, G.; Torresin, A.; Agosteo, S.; Foglio Para, A.; Sangiust, V.; Zeni, L; Silari, M. Neutron measurements around medical electron accelerators by active and passive detection techniques. Med. Phys. 18:54-60; 1991.
    • (1991) Med. Phys. , vol.18 , pp. 54-60
    • Tosi, G.1    Torresin, A.2    Agosteo, S.3    Foglio Para, A.4    Sangiust, V.5    Zeni, L.6    Silari, M.7
  • 20
    • 0022485431 scopus 로고
    • Measurement and calculation of neutron leakage from a medical electron accelerator
    • Uwamino, Y.; Nakamura, T.; Ohkubo, T.; Hara, A. Measurement and calculation of neutron leakage from a medical electron accelerator. Med. Phys. 13:374-384; 1986.
    • (1986) Med. Phys. , vol.13 , pp. 374-384
    • Uwamino, Y.1    Nakamura, T.2    Ohkubo, T.3    Hara, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.