Volumn 20, Issue 2, 1998, Pages 81-86

The Haematology Analyser SF-3000: Performance of the automated white blood cell differential count in comparison to the Haematology Analyser NE- 1500

Author keywords

Analyser; Differential; Haematology; NB 1500; SF 3000

Indexed keywords

ARTICLE; BASOPHIL; CELL COUNT; CELL FRACTIONATION; DIFFERENTIAL DIAGNOSIS; HUMAN; HUMAN CELL; INTERMETHOD COMPARISON; MONOCYTE; NEUTROPHIL; PRIORITY JOURNAL;

EID: 0031968644     PISSN: 01419854     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-2257.1998.00093.x     Document Type: Article
Times cited : (8)

References (14)
  • 3
    • 0026096493 scopus 로고
    • Monocyte counting: Discrepancies in results obtained with different automated instruments
    • Goossens W., van Hove L. & Verwilghen R.L. (1991) Monocyte counting: discrepancies in results obtained with different automated instruments. Journal of Clinical Pathology 44, 224-227.
    • (1991) Journal of Clinical Pathology , vol.44 , pp. 224-227
    • Goossens, W.1    Van Hove, L.2    Verwilghen, R.L.3
  • 4
    • 0002249250 scopus 로고
    • Performance evaluation of the Sysmex SE-9000™ haematology workstation
    • Houwen B., Chang L., Chen W. et al. (1994) Performance evaluation of the Sysmex SE-9000™ haematology workstation Sysmex Journal International 4, 5 17.
    • (1994) Sysmex Journal International , vol.4 , pp. 5-17
    • Houwen, B.1    Chang, L.2    Chen, W.3
  • 5
    • 0027144484 scopus 로고
    • Evaluation of performance for automated differential leukocyte counting on Sysmex NE-8000 by NCCLS recommended protocol. H20-T
    • Hu C.Y., Wang C.H., Chuang H.M. & Shen M.C. (1993) Evaluation of performance for automated differential leukocyte counting on Sysmex NE-8000 by NCCLS recommended protocol. H20-T. Clinical and Laboratory Haematology 15, 287-299.
    • (1993) Clinical and Laboratory Haematology , vol.15 , pp. 287-299
    • Hu, C.Y.1    Wang, C.H.2    Chuang, H.M.3    Shen, M.C.4
  • 7
    • 0027231354 scopus 로고
    • The white cell differential: Personal observations
    • Reardon D.M. & Warner B. (1993) The white cell differential: personal observations. Journal of Clinical Pathology 46, 289-291.
    • (1993) Journal of Clinical Pathology , vol.46 , pp. 289-291
    • Reardon, D.M.1    Warner, B.2
  • 8
    • 7144232420 scopus 로고    scopus 로고
    • Fundamental study on the automated haematology analyser SF-8000™ especially on sensitivity of detecting immature cells
    • Sano S., koyanagi I., Tsuchi M. et al. (1996) Fundamental study on the automated haematology analyser SF-8000™ especially on sensitivity of detecting immature cells. Sysmex Journal International 6, 16 27.
    • (1996) Sysmex Journal International , vol.6 , pp. 16-27
    • Sano, S.1    Koyanagi, I.2    Tsuchi, M.3
  • 10
    • 0343808064 scopus 로고
    • Performance evaluation of the Sysmex SE-9000™ haematology workstation
    • Summer J. & Garvey M.B. (1994) Performance evaluation of the Sysmex SE-9000™ haematology workstation. Sysmex Journal International 4, 127 136
    • (1994) Sysmex Journal International , vol.4 , pp. 127-136
    • Summer, J.1    Garvey, M.B.2
  • 11
    • 0025971963 scopus 로고
    • Laboratory and clinical evaluation of white blood cell differential counts. Comparison of the Coulter VCS. Technicon H-1, and 800-cell manual method
    • Swaim W.R. (1991) Laboratory and clinical evaluation of white blood cell differential counts. Comparison of the Coulter VCS. Technicon H-1, and 800-cell manual method. Amerícan Journal of Clinical Pathology 95, 381 388.
    • (1991) Amerícan Journal of Clinical Pathology , vol.95 , pp. 381-388
    • Swaim, W.R.1
  • 13
    • 17144463591 scopus 로고    scopus 로고
    • Automated live-part white blood cell (WBC) differential counts: Efficiency of software generated WBC suspect flags of the haematology analysers SE-9000, NE-8000 and Coulter STKS
    • Thalhammer-Scherrer R., Knöbl P., Korninger I., & Schwarzinger I. (1997) Automated live-part white blood cell (WBC) differential counts: efficiency of software generated WBC suspect flags of the haematology analysers SE-9000, NE-8000 and Coulter STKS. Archives of Pathology and Laboratory Medicine 121, 573-577.
    • (1997) Archives of Pathology and Laboratory Medicine , vol.121 , pp. 573-577
    • Thalhammer-Scherrer, R.1    Knöbl, P.2    Korninger, I.3    Schwarzinger, I.4
  • 14
    • 84920316100 scopus 로고    scopus 로고
    • Evaluation of the automated haematology analyser Sysmex SF-8000
    • TOA Medical Electronics Co. Ltd (1996) Evaluation of the automated haematology analyser Sysmex SF-8000. Sysmex Journal International 6, 4-15.
    • (1996) Sysmex Journal International , vol.6 , pp. 4-15