메뉴 건너뛰기




Volumn 35, Issue 1, 1998, Pages 120-127

Alkaline phosphatase activity measurement in the UK by AMP-buffered methods: An appraisal of current practice

Author keywords

2 amimo 2 methyl 1 propanol; external quality assessment; Isoenzymes; Reference ranges

Indexed keywords

2 AMINO 2 METHYLPROPANOL; ADENOSINE PHOSPHATE; ALKALINE PHOSPHATASE; BUFFER; UNCLASSIFIED DRUG;

EID: 0031962586     PISSN: 00045632     EISSN: None     Source Type: Journal    
DOI: 10.1177/000456329803500117     Document Type: Article
Times cited : (8)

References (7)
  • 1
    • 84990293701 scopus 로고
    • IFCC methods for the measurement of catalytic concentration of enzymes part 5, IFCC method for alkaline phosphatase (orthophosphoric monoester phosphohydrolase, alkaline optimum, E.C.3.1.3.1.)
    • International Federation of Clinical Chemistry. IFCC methods for the measurement of catalytic concentration of enzymes part 5, IFCC method for alkaline phosphatase (orthophosphoric monoester phosphohydrolase, alkaline optimum, E.C.3.1.3.1.). J Clin Chem Clin Biochem 1983; 21: 731-48
    • (1983) J Clin Chem Clin Biochem , vol.21 , pp. 731-748
  • 2
    • 0018792666 scopus 로고
    • IFCC methods for the measurement of catalytic concentration of enzymes part 1. General considerations concerning the determination of the catalytic concentration of an enzyme in the blood serum or plasma of man
    • International Federation of Clinical Chemistry. IFCC methods for the measurement of catalytic concentration of enzymes part 1. General considerations concerning the determination of the catalytic concentration of an enzyme in the blood serum or plasma of man. Clin Chim Acta 1979; 98: 163F-74F
    • (1979) Clin Chim Acta , vol.98
  • 3
    • 2442584509 scopus 로고
    • Recommendations for measuring the catalytic concentration of alkaline phosphatase in human serum at +30 C
    • Société Française de Biologie Clinique. Enzymology Commission. Recommendations for measuring the catalytic concentration of alkaline phosphatase in human serum at +30 C. Ann Biol Clin 1982; 40: 150-4
    • (1982) Ann Biol Clin , vol.40 , pp. 150-154
  • 4
    • 0019488731 scopus 로고
    • Response-surface-optimized, zinc-enhanced assay for serum alkaline phosphatase
    • Thompson JC, Hodges CT, Dobler GL, Williamson JA. Response-surface-optimized, zinc-enhanced assay for serum alkaline phosphatase. Clin Chem 1981; 27: 1171-5
    • (1981) Clin Chem , vol.27 , pp. 1171-1175
    • Thompson, J.C.1    Hodges, C.T.2    Dobler, G.L.3    Williamson, J.A.4
  • 5
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i: 307-10
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 6
    • 0022881490 scopus 로고
    • Reference intervals for alkaline phosphatase activity determined by the IFCC and AACC reference methods
    • Tietz NW, Shuey DF. Reference intervals for alkaline phosphatase activity determined by the IFCC and AACC reference methods. Clin Chem 1986; 32: 1593-4
    • (1986) Clin Chem , vol.32 , pp. 1593-1594
    • Tietz, N.W.1    Shuey, D.F.2
  • 7
    • 0031014322 scopus 로고    scopus 로고
    • Enzyme standardization - The way forward?
    • Moss DW. Enzyme standardization - the way forward? Ann Clin Biochem 1997; 34: 13-6
    • (1997) Ann Clin Biochem , vol.34 , pp. 13-16
    • Moss, D.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.