Volumn 7, Issue 2, 1998, Pages 151-157

Durability/wear testing of heart valve substitutes

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIOPROSTHESIS; COMPLIANCE (PHYSICAL); FOOD AND DRUG ADMINISTRATION; HEART OUTPUT; HEART VALVE PROSTHESIS; PIEZOELECTRICITY; PRIORITY JOURNAL;

EID: 0031961462     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (13)

References (10)
  • 1
    • 0029937159 scopus 로고    scopus 로고
    • In vitro testing of heart valve wear outside of the manufacturer's laboratory-requirements and controversies
    • Reul H, Eichler M, Potthast K, Schmitz C, Rau G. In vitro testing of heart valve wear outside of the manufacturer's laboratory-requirements and controversies. J Heart Valve Dis 1996;5(Suppl. I):S97-S104
    • (1996) J Heart Valve Dis , vol.5 , Issue.1 SUPPL.
    • Reul, H.1    Eichler, M.2    Potthast, K.3    Schmitz, C.4    Rau, G.5
  • 2
    • 0029156389 scopus 로고
    • The effect of left ventricular dp/dt on the in vitro dynamics of Björk-Shiley convexo-concave mitral valves
    • Rau G, Reul H, Eichler M, Schreck S, Wieting DW. The effect of left ventricular dp/dt on the in vitro dynamics of Björk-Shiley convexo-concave mitral valves. J Heart Valve Dis 1995;4(Suppl. I):S17-S20
    • (1995) J Heart Valve Dis , vol.4 , Issue.1 SUPPL.
    • Rau, G.1    Reul, H.2    Eichler, M.3    Schreck, S.4    Wieting, D.W.5
  • 3
    • 0029100302 scopus 로고
    • Dynamics of Björk-Shiley convexo-concave mitral valves in sheep
    • Schreck S, Inderbitzen R, Chien H, et al. Dynamics of Björk-Shiley convexo-concave mitral valves in sheep. J Heart Valve Dis 1995;4(Suppl. I):S21-S25
    • (1995) J Heart Valve Dis , vol.4 , Issue.1 SUPPL.
    • Schreck, S.1    Inderbitzen, R.2    Chien, H.3
  • 5
    • 0023213698 scopus 로고
    • Patterns of failure in Ionescu-Shiley bovine pericardial bioprosthetic valves
    • Walley VM, Keon WJ. Patterns of failure in Ionescu-Shiley bovine pericardial bioprosthetic valves. J Thorac Cardiovasc Surg 1987;93:S925-S933
    • (1987) J Thorac Cardiovasc Surg , vol.93
    • Walley, V.M.1    Keon, W.J.2
  • 6
    • 0027642707 scopus 로고
    • Numerical simulation of leaflet flexure in bioprosthetic valves mounted in rigid and expansile stents
    • Krucinski S, Vesely I, Dokainish MA, Campbell G. Numerical simulation of leaflet flexure in bioprosthetic valves mounted in rigid and expansile stents. J Biomech 1993;26(8):S929-S943
    • (1993) J Biomech , vol.26 , Issue.8
    • Krucinski, S.1    Vesely, I.2    Dokainish, M.A.3    Campbell, G.4
  • 7
    • 0024441115 scopus 로고
    • Analysis of the bending behaviour of porcine xenograft leaflets and of natural aortic valve material. Bending stiffness, neutral axis and shear measurements
    • Vesely I, Boughner DR. Analysis of the bending behaviour of porcine xenograft leaflets and of natural aortic valve material. Bending stiffness, neutral axis and shear measurements. J Biomech 1989;22(6/7):S655-S671
    • (1989) J Biomech , vol.22 , Issue.6-7
    • Vesely, I.1    Boughner, D.R.2
  • 8
    • 0023755406 scopus 로고
    • Tissue buckling as a mechanism of bioprosthetic valve failure
    • Vesely L, Boughner DR, Song T, Tissue buckling as a mechanism of bioprosthetic valve failure. Ann Thorac Surg 1988;46:S302-S308
    • (1988) Ann Thorac Surg , vol.46
    • Vesely, L.1    Boughner, D.R.2    Song, T.3
  • 10
    • 0029112749 scopus 로고
    • Bioprosthetic valve tissue viscoelasticity: Implications on accelerated pulse duplicator testing
    • Vesely I, Boughner DR, Leeson-Dietrich J. Bioprosthetic valve tissue viscoelasticity: Implications on accelerated pulse duplicator testing. Ann Thorac Surg 1995;60(2):S379-S382
    • (1995) Ann Thorac Surg , vol.60 , Issue.2
    • Vesely, I.1    Boughner, D.R.2    Leeson-Dietrich, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.