메뉴 건너뛰기




Volumn 92, Issue 3, 1998, Pages 584-587

Transcutaneous monitoring of blood gases: Is it comparable with arterialized earlobe sampling?

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTERIAL BLOOD; ARTERIAL CARBON DIOXIDE TENSION; ARTERIAL OXYGEN TENSION; ARTICLE; BLOOD GAS ANALYSIS; BLOOD SAMPLING; CARBON DIOXIDE TENSION; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; EAR LOBE; FEMALE; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; MALE; NORMAL HUMAN; PRIORITY JOURNAL; RELIABILITY; TRANSCUTANEOUS OXYGEN MONITORING;

EID: 0031955701     PISSN: 09546111     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0954-6111(98)90313-4     Document Type: Article
Times cited : (17)

References (18)
  • 1
    • 0015591649 scopus 로고
    • Complications of percutaneous radial artery cannulation: An objective prospective study in man
    • Bedford R, Wollman H. Complications of percutaneous radial artery cannulation: an objective prospective study in man. Anaesthesiology 1973; 38: 228-236.
    • (1973) Anaesthesiology , vol.38 , pp. 228-236
    • Bedford, R.1    Wollman, H.2
  • 2
    • 0015515725 scopus 로고
    • Pulseless arm after brachial artery catheterisation
    • Machleder HI, Sweeney JP, Barker WF. Pulseless arm after brachial artery catheterisation. Lancet 1972; 1: 407-409.
    • (1972) Lancet , vol.1 , pp. 407-409
    • Machleder, H.I.1    Sweeney, J.P.2    Barker, W.F.3
  • 3
    • 0017722251 scopus 로고
    • Radial artery function following percutaneous cannulation with 18- and 20-gauge catheters
    • Bedford R. Radial artery function following percutaneous cannulation with 18- and 20-gauge catheters. Anaesthesiology 1977; 47: 37-39.
    • (1977) Anaesthesiology , vol.47 , pp. 37-39
    • Bedford, R.1
  • 5
    • 0028334818 scopus 로고
    • Arterialised earlobe blood gas analysis: An underused technique
    • Pitkin AD, Roberts CM, Wedzicha JA. Arterialised earlobe blood gas analysis: an underused technique. Thorax 1994; 49 (4): 364-366.
    • (1994) Thorax , vol.49 , Issue.4 , pp. 364-366
    • Pitkin, A.D.1    Roberts, C.M.2    Wedzicha, J.A.3
  • 6
    • 0028817632 scopus 로고
    • Arterial versus capillary sampling for analysing blood gas pressures
    • Dar K, Williams T, Aitken R, Woods KL, Fletcher S. Arterial versus capillary sampling for analysing blood gas pressures. Br Med J 1995; 310: 24-25.
    • (1995) Br Med J , vol.310 , pp. 24-25
    • Dar, K.1    Williams, T.2    Aitken, R.3    Woods, K.L.4    Fletcher, S.5
  • 10
    • 0027158238 scopus 로고
    • Use of a combined oxygen and carbon dioxide transcutaneous electrode in the estimation of gas exchange during exercise
    • Sridhar MK, Carter R, Moran F, Banham SW. Use of a combined oxygen and carbon dioxide transcutaneous electrode in the estimation of gas exchange during exercise. Thorax 1993; 48: 643-647.
    • (1993) Thorax , vol.48 , pp. 643-647
    • Sridhar, M.K.1    Carter, R.2    Moran, F.3    Banham, S.W.4
  • 11
    • 0019622489 scopus 로고
    • Transcutaneous oxygen monitoring of critically ill adults, with and without low flow shock
    • Tremper KK, Shoemaker WC. Transcutaneous oxygen monitoring of critically ill adults, with and without low flow shock. Crit Care Med 1981; 9 (10): 706-709.
    • (1981) Crit Care Med , vol.9 , Issue.10 , pp. 706-709
    • Tremper, K.K.1    Shoemaker, W.C.2
  • 13
    • 0006759499 scopus 로고
    • The measurement of transcutaneous oxygen and carbon dioxide tension during exercise testing
    • Carter R. The measurement of transcutaneous oxygen and carbon dioxide tension during exercise testing. Breath 1989; 38: 2-5.
    • (1989) Breath , vol.38 , pp. 2-5
    • Carter, R.1
  • 16
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 0027190021 scopus 로고
    • 2 measurements at 37 degrees C and 44 degrees C in patients with claudication in consideration of provocation tests
    • 2 measurements at 37 degrees C and 44 degrees C in patients with claudication in consideration of provocation tests. Vasa 1993; 22 (2): 129-36.
    • (1993) Vasa , vol.22 , Issue.2 , pp. 129-136
    • Caspary, L.1    Creutzig, A.2    Alexander, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.