1
-
-
0015591649
-
Complications of percutaneous radial artery cannulation: An objective prospective study in man
-
Bedford R, Wollman H. Complications of percutaneous radial artery cannulation: an objective prospective study in man. Anaesthesiology 1973; 38: 228-236.
-
(1973)
Anaesthesiology
, vol.38
, pp. 228-236
-
-
Bedford, R.1
Wollman, H.2
-
2
-
-
0015515725
-
Pulseless arm after brachial artery catheterisation
-
Machleder HI, Sweeney JP, Barker WF. Pulseless arm after brachial artery catheterisation. Lancet 1972; 1: 407-409.
-
(1972)
Lancet
, vol.1
, pp. 407-409
-
-
Machleder, H.I.1
Sweeney, J.P.2
Barker, W.F.3
-
3
-
-
0017722251
-
Radial artery function following percutaneous cannulation with 18- and 20-gauge catheters
-
Bedford R. Radial artery function following percutaneous cannulation with 18- and 20-gauge catheters. Anaesthesiology 1977; 47: 37-39.
-
(1977)
Anaesthesiology
, vol.47
, pp. 37-39
-
-
Bedford, R.1
-
5
-
-
0028334818
-
Arterialised earlobe blood gas analysis: An underused technique
-
Pitkin AD, Roberts CM, Wedzicha JA. Arterialised earlobe blood gas analysis: an underused technique. Thorax 1994; 49 (4): 364-366.
-
(1994)
Thorax
, vol.49
, Issue.4
, pp. 364-366
-
-
Pitkin, A.D.1
Roberts, C.M.2
Wedzicha, J.A.3
-
6
-
-
0028817632
-
Arterial versus capillary sampling for analysing blood gas pressures
-
Dar K, Williams T, Aitken R, Woods KL, Fletcher S. Arterial versus capillary sampling for analysing blood gas pressures. Br Med J 1995; 310: 24-25.
-
(1995)
Br Med J
, vol.310
, pp. 24-25
-
-
Dar, K.1
Williams, T.2
Aitken, R.3
Woods, K.L.4
Fletcher, S.5
-
10
-
-
0027158238
-
Use of a combined oxygen and carbon dioxide transcutaneous electrode in the estimation of gas exchange during exercise
-
Sridhar MK, Carter R, Moran F, Banham SW. Use of a combined oxygen and carbon dioxide transcutaneous electrode in the estimation of gas exchange during exercise. Thorax 1993; 48: 643-647.
-
(1993)
Thorax
, vol.48
, pp. 643-647
-
-
Sridhar, M.K.1
Carter, R.2
Moran, F.3
Banham, S.W.4
-
11
-
-
0019622489
-
Transcutaneous oxygen monitoring of critically ill adults, with and without low flow shock
-
Tremper KK, Shoemaker WC. Transcutaneous oxygen monitoring of critically ill adults, with and without low flow shock. Crit Care Med 1981; 9 (10): 706-709.
-
(1981)
Crit Care Med
, vol.9
, Issue.10
, pp. 706-709
-
-
Tremper, K.K.1
Shoemaker, W.C.2
-
13
-
-
0006759499
-
The measurement of transcutaneous oxygen and carbon dioxide tension during exercise testing
-
Carter R. The measurement of transcutaneous oxygen and carbon dioxide tension during exercise testing. Breath 1989; 38: 2-5.
-
(1989)
Breath
, vol.38
, pp. 2-5
-
-
Carter, R.1
-
16
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
18
-
-
0027190021
-
2 measurements at 37 degrees C and 44 degrees C in patients with claudication in consideration of provocation tests
-
2 measurements at 37 degrees C and 44 degrees C in patients with claudication in consideration of provocation tests. Vasa 1993; 22 (2): 129-36.
-
(1993)
Vasa
, vol.22
, Issue.2
, pp. 129-136
-
-
Caspary, L.1
Creutzig, A.2
Alexander, K.3
|