메뉴 건너뛰기




Volumn 82, Issue 3, 1998, Pages 260-266

Clinical evaluation of scanning laser polarimetry: II polar profile shape analysis

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; BLOOD VESSEL; CLINICAL TRIAL; CONTROLLED STUDY; DATA BASE; FEMALE; GLAUCOMA; HUMAN; HUMAN EXPERIMENT; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; NERVE FIBER; NORMAL HUMAN; POLARIMETRY; PRIORITY JOURNAL; RETINA NERVE CELL; SCANNING LASER POLARIMETRY; STANDARDIZATION; THICKNESS;

EID: 0031955496     PISSN: 00071161     EISSN: None     Source Type: Journal    
DOI: 10.1136/bjo.82.3.260     Document Type: Article
Times cited : (13)

References (17)
  • 1
    • 0025329536 scopus 로고
    • Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fibre layer thickness
    • Weinreb RN, Dreher AW, Coleman, A, et al. Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fibre layer thickness. Arch Ophthalmol 1990;108:557-60.
    • (1990) Arch Ophthalmol , vol.108 , pp. 557-560
    • Weinreb, R.N.1    Dreher, A.W.2    Coleman, A.3
  • 2
    • 0027055101 scopus 로고
    • Retinal laser ellipsometry: A new method for measuring the retinal nerve fibre layer thickness distribution
    • Dreher AW, Reiter K. Retinal laser ellipsometry: a new method for measuring the retinal nerve fibre layer thickness distribution. Clin Vis Sci 1992;7:481-8.
    • (1992) Clin Vis Sci , vol.7 , pp. 481-488
    • Dreher, A.W.1    Reiter, K.2
  • 3
    • 0001188112 scopus 로고
    • Spatially resolved birefringence of the retinal nerve fibre layer assessed with a retinal laser ellipsometer
    • Dreher AW, Reiter K, Weinreb RN. Spatially resolved birefringence of the retinal nerve fibre layer assessed with a retinal laser ellipsometer. Appl Optics 1992;31:3730-5.
    • (1992) Appl Optics , vol.31 , pp. 3730-3735
    • Dreher, A.W.1    Reiter, K.2    Weinreb, R.N.3
  • 4
    • 0029044003 scopus 로고
    • Scanning laser polarimetry to measure the nerve fibre layer of normal and glaucomatous eyes
    • Weinreb RN, Shakiba S, Zangwill L. Scanning laser polarimetry to measure the nerve fibre layer of normal and glaucomatous eyes. Am J Ophthalmol 1995;119:627-36.
    • (1995) Am J Ophthalmol , vol.119 , pp. 627-636
    • Weinreb, R.N.1    Shakiba, S.2    Zangwill, L.3
  • 5
    • 0028864556 scopus 로고
    • Association between quantitative nerve fibre layer measurement and visual loss in glaucoma
    • Weinreb RN, Shakiba S, Sample PA, et al. Association between quantitative nerve fibre layer measurement and visual loss in glaucoma. Am J Ophthalmol 1995;120:732-8.
    • (1995) Am J Ophthalmol , vol.120 , pp. 732-738
    • Weinreb, R.N.1    Shakiba, S.2    Sample, P.A.3
  • 6
    • 0029965458 scopus 로고    scopus 로고
    • Retinal nerve fibre layer assessment by scanning laser polarimetry and standardized photography
    • Niessen AGJE, van der Berg TJTP, Langerhorst CT, Greve EL. Retinal nerve fibre layer assessment by scanning laser polarimetry and standardized photography. Am J Ophthalmol 1996;121:484-93.
    • (1996) Am J Ophthalmol , vol.121 , pp. 484-493
    • Niessen, A.G.J.E.1    Van Der Berg, T.J.T.P.2    Langerhorst, C.T.3    Greve, E.L.4
  • 7
    • 27844465826 scopus 로고
    • Improving the reproducibility of the nerve fiber analyzer retinal nerve fibre layer profiles with a blood vessel removal algorithm
    • Waldock A, Karwatowski WSS, Potts MJ. Improving the reproducibility of the nerve fiber analyzer retinal nerve fibre layer profiles with a blood vessel removal algorithm. Invest Ophthalmol Vis Sci (Suppl) 1995;36:S973.
    • (1995) Invest Ophthalmol Vis Sci (Suppl) , vol.36
    • Waldock, A.1    Karwatowski, W.S.S.2    Potts, M.J.3
  • 9
    • 27844604894 scopus 로고    scopus 로고
    • Clinical interpretation of the nerve fibre layer profiles obtained with the scanning laser polarimeter
    • Waldock A, Karwatowski WSS, Potts MJ. Clinical interpretation of the nerve fibre layer profiles obtained with the scanning laser polarimeter. Invest Ophthalmol Vis Sci (Suppl) 1996;37:S1095.
    • (1996) Invest Ophthalmol Vis Sci (Suppl) , vol.37
    • Waldock, A.1    Karwatowski, W.S.S.2    Potts, M.J.3
  • 11
    • 0026963754 scopus 로고
    • Scanning laser polarimetry of the retinal nerve fibre layer
    • Dreher AW, Reiter K. Scanning laser polarimetry of the retinal nerve fibre layer. Proc SPIE Int Soc Opt Eng 1992;1746: 34-8.
    • (1992) Proc SPIE Int Soc Opt Eng , vol.1746 , pp. 34-38
    • Dreher, A.W.1    Reiter, K.2
  • 12
    • 0027457620 scopus 로고
    • Receiver-operating characteristic (ROC) plots:a fundamental tool in clinical medicine
    • Zweig MH, Campbell G. Receiver-operating characteristic (ROC) plots:a fundamental tool in clinical medicine. Clin Chem 1993;39:561-77.
    • (1993) Clin Chem , vol.39 , pp. 561-577
    • Zweig, M.H.1    Campbell, G.2
  • 13
  • 14
    • 0026410735 scopus 로고
    • Comparison of analytic algorithms for detecting glaucomatous visual field loss
    • Katz J, Sommer A, Gaasterland DE, Anderson DR. Comparison of analytic algorithms for detecting glaucomatous visual field loss. Arch Ophthalmol 1991;109:1684-9.
    • (1991) Arch Ophthalmol , vol.109 , pp. 1684-1689
    • Katz, J.1    Sommer, A.2    Gaasterland, D.E.3    Anderson, D.R.4
  • 15
    • 0028310833 scopus 로고
    • Screening for glaucoma in a medical clinic with photographs of the nerve fibre layer
    • Wang F, Quigley HA, Tielsch JM. Screening for glaucoma in a medical clinic with photographs of the nerve fibre layer. Arch Ophthalmol 1994;112:796-800.
    • (1994) Arch Ophthalmol , vol.112 , pp. 796-800
    • Wang, F.1    Quigley, H.A.2    Tielsch, J.M.3
  • 16
    • 0031049984 scopus 로고    scopus 로고
    • The sensitivity and specificity of nerve fibre layer measurements in glaucoma as determined with scanning laser polarimetry
    • Tjon-Fo-Sang MJ, Lemij HG. The sensitivity and specificity of nerve fibre layer measurements in glaucoma as determined with scanning laser polarimetry. Am J Ophthalmol 1997;123:62-9.
    • (1997) Am J Ophthalmol , vol.123 , pp. 62-69
    • Tjon-Fo-Sang, M.J.1    Lemij, H.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.