1
-
-
0025329536
-
Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fibre layer thickness
-
Weinreb RN, Dreher AW, Coleman, A, et al. Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fibre layer thickness. Arch Ophthalmol 1990;108:557-60.
-
(1990)
Arch Ophthalmol
, vol.108
, pp. 557-560
-
-
Weinreb, R.N.1
Dreher, A.W.2
Coleman, A.3
-
2
-
-
0027055101
-
Retinal laser ellipsometry: A new method for measuring the retinal nerve fibre layer thickness distribution
-
Dreher AW, Reiter K. Retinal laser ellipsometry: a new method for measuring the retinal nerve fibre layer thickness distribution. Clin Vis Sci 1992;7:481-8.
-
(1992)
Clin Vis Sci
, vol.7
, pp. 481-488
-
-
Dreher, A.W.1
Reiter, K.2
-
3
-
-
0001188112
-
Spatially resolved birefringence of the retinal nerve fibre layer assessed with a retinal laser ellipsometer
-
Dreher AW, Reiter K, Weinreb RN. Spatially resolved birefringence of the retinal nerve fibre layer assessed with a retinal laser ellipsometer. Appl Optics 1992;31:3730-5.
-
(1992)
Appl Optics
, vol.31
, pp. 3730-3735
-
-
Dreher, A.W.1
Reiter, K.2
Weinreb, R.N.3
-
4
-
-
0029044003
-
Scanning laser polarimetry to measure the nerve fibre layer of normal and glaucomatous eyes
-
Weinreb RN, Shakiba S, Zangwill L. Scanning laser polarimetry to measure the nerve fibre layer of normal and glaucomatous eyes. Am J Ophthalmol 1995;119:627-36.
-
(1995)
Am J Ophthalmol
, vol.119
, pp. 627-636
-
-
Weinreb, R.N.1
Shakiba, S.2
Zangwill, L.3
-
5
-
-
0028864556
-
Association between quantitative nerve fibre layer measurement and visual loss in glaucoma
-
Weinreb RN, Shakiba S, Sample PA, et al. Association between quantitative nerve fibre layer measurement and visual loss in glaucoma. Am J Ophthalmol 1995;120:732-8.
-
(1995)
Am J Ophthalmol
, vol.120
, pp. 732-738
-
-
Weinreb, R.N.1
Shakiba, S.2
Sample, P.A.3
-
7
-
-
27844465826
-
Improving the reproducibility of the nerve fiber analyzer retinal nerve fibre layer profiles with a blood vessel removal algorithm
-
Waldock A, Karwatowski WSS, Potts MJ. Improving the reproducibility of the nerve fiber analyzer retinal nerve fibre layer profiles with a blood vessel removal algorithm. Invest Ophthalmol Vis Sci (Suppl) 1995;36:S973.
-
(1995)
Invest Ophthalmol Vis Sci (Suppl)
, vol.36
-
-
Waldock, A.1
Karwatowski, W.S.S.2
Potts, M.J.3
-
9
-
-
27844604894
-
Clinical interpretation of the nerve fibre layer profiles obtained with the scanning laser polarimeter
-
Waldock A, Karwatowski WSS, Potts MJ. Clinical interpretation of the nerve fibre layer profiles obtained with the scanning laser polarimeter. Invest Ophthalmol Vis Sci (Suppl) 1996;37:S1095.
-
(1996)
Invest Ophthalmol Vis Sci (Suppl)
, vol.37
-
-
Waldock, A.1
Karwatowski, W.S.S.2
Potts, M.J.3
-
11
-
-
0026963754
-
Scanning laser polarimetry of the retinal nerve fibre layer
-
Dreher AW, Reiter K. Scanning laser polarimetry of the retinal nerve fibre layer. Proc SPIE Int Soc Opt Eng 1992;1746: 34-8.
-
(1992)
Proc SPIE Int Soc Opt Eng
, vol.1746
, pp. 34-38
-
-
Dreher, A.W.1
Reiter, K.2
-
12
-
-
0027457620
-
Receiver-operating characteristic (ROC) plots:a fundamental tool in clinical medicine
-
Zweig MH, Campbell G. Receiver-operating characteristic (ROC) plots:a fundamental tool in clinical medicine. Clin Chem 1993;39:561-77.
-
(1993)
Clin Chem
, vol.39
, pp. 561-577
-
-
Zweig, M.H.1
Campbell, G.2
-
13
-
-
4243225274
-
Reproducibility improvement of the nerve fiber analyzer by applying a blood vessel removal algorithm
-
Dreher, AW, Reed GC, Zyzyck J, Zhou Q, Reiter K. Reproducibility improvement of the nerve fiber analyzer by applying a blood vessel removal algorithm. Invest Ophthalmol Vis Sci (Suppl) 1996;37:S1093.
-
(1996)
Invest Ophthalmol Vis Sci (Suppl)
, vol.37
-
-
Dreher, A.W.1
Reed, G.C.2
Zyzyck, J.3
Zhou, Q.4
Reiter, K.5
-
14
-
-
0026410735
-
Comparison of analytic algorithms for detecting glaucomatous visual field loss
-
Katz J, Sommer A, Gaasterland DE, Anderson DR. Comparison of analytic algorithms for detecting glaucomatous visual field loss. Arch Ophthalmol 1991;109:1684-9.
-
(1991)
Arch Ophthalmol
, vol.109
, pp. 1684-1689
-
-
Katz, J.1
Sommer, A.2
Gaasterland, D.E.3
Anderson, D.R.4
-
15
-
-
0028310833
-
Screening for glaucoma in a medical clinic with photographs of the nerve fibre layer
-
Wang F, Quigley HA, Tielsch JM. Screening for glaucoma in a medical clinic with photographs of the nerve fibre layer. Arch Ophthalmol 1994;112:796-800.
-
(1994)
Arch Ophthalmol
, vol.112
, pp. 796-800
-
-
Wang, F.1
Quigley, H.A.2
Tielsch, J.M.3
-
16
-
-
0031049984
-
The sensitivity and specificity of nerve fibre layer measurements in glaucoma as determined with scanning laser polarimetry
-
Tjon-Fo-Sang MJ, Lemij HG. The sensitivity and specificity of nerve fibre layer measurements in glaucoma as determined with scanning laser polarimetry. Am J Ophthalmol 1997;123:62-9.
-
(1997)
Am J Ophthalmol
, vol.123
, pp. 62-69
-
-
Tjon-Fo-Sang, M.J.1
Lemij, H.G.2
|