메뉴 건너뛰기




Volumn 74, Issue 2-3, 1998, Pages 333-335

Management of cardiac pacemaker in a patient with spinal cord stimulator implant

Author keywords

Angina; Cardiac pacemaker; Claudication; Ischaemic heart disease; Peripheral vascular disease; Spinal cord stimulator

Indexed keywords

AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CASE REPORT; HEART MUSCLE ISCHEMIA; HEART PACING; HUMAN; LEG ISCHEMIA; MALE; NERVE STIMULATION; PAIN; PRIORITY JOURNAL; SPINAL CORD STIMULATION;

EID: 0031952497     PISSN: 03043959     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0304-3959(97)00171-1     Document Type: Article
Times cited : (34)

References (9)
  • 1
    • 0025302359 scopus 로고
    • Management of spinal cord stimulators in patients with cardiac pacemakers
    • Anderson C., Oxhøj J., Arnsbo P. Management of spinal cord stimulators in patients with cardiac pacemakers. PACE. 13:1990;574-577.
    • (1990) PACE , vol.13 , pp. 574-577
    • Anderson, C.1    Oxhøj, J.2    Arnsbo, P.3
  • 2
    • 0021856640 scopus 로고
    • Epidural electrical stimulation in severe ischaemia. Evidence of pain relief, increased blood flow and a possible limb saving effect
    • Augustinsson L.E., Holm J., Carlsson C.A., Jivegard L. Epidural electrical stimulation in severe ischaemia. Evidence of pain relief, increased blood flow and a possible limb saving effect. Ann. Surg. 202:1985;104-111.
    • (1985) Ann. Surg. , vol.202 , pp. 104-111
    • Augustinsson, L.E.1    Holm, J.2    Carlsson, C.A.3    Jivegard, L.4
  • 3
    • 0023275904 scopus 로고
    • The NASPE/BPEG generic pacemaker code for antibradyarrhythmia and adaptive-rate pacing and antitachyarrhythmia devices
    • Bernstein A.D., Camm A.J., Fletcher R.D., Gold R.D., Rickards A.F., Smyth N.P.D., Speilman S.R., Sutton R. The NASPE/BPEG generic pacemaker code for antibradyarrhythmia and adaptive-rate pacing and antitachyarrhythmia devices. PACE. 10:1987;794-799.
    • (1987) PACE , vol.10 , pp. 794-799
    • Bernstein, A.D.1    Camm, A.J.2    Fletcher, R.D.3    Gold, R.D.4    Rickards, A.F.5    Smyth, N.P.D.6    Speilman, S.R.7    Sutton, R.8
  • 5
    • 0021216276 scopus 로고
    • The clinical incidence and significance of myopotential sensing with unipolar pacemakers
    • Fetter J., Bodeldyk G.L., Engman F.J. The clinical incidence and significance of myopotential sensing with unipolar pacemakers. PACE. 7:1984;871-881.
    • (1984) PACE , vol.7 , pp. 871-881
    • Fetter, J.1    Bodeldyk, G.L.2    Engman, F.J.3
  • 6
    • 0029073850 scopus 로고
    • Effects of spinal cord stimulation (SCS) in patients with inoperable severe lower limb ischaemia: A prospective randomised controlled study
    • Jivegard L.E.H., Augustinsson L.E., Holm J., Risberg B., Ortenwall P. Effects of spinal cord stimulation (SCS) in patients with inoperable severe lower limb ischaemia: a prospective randomised controlled study. Eur. J. Vasc. Endovasc. Surg. 9:1995;421-425.
    • (1995) Eur. J. Vasc. Endovasc. Surg. , vol.9 , pp. 421-425
    • Jivegard, L.E.H.1    Augustinsson, L.E.2    Holm, J.3    Risberg, B.4    Ortenwall, P.5
  • 7
    • 0015887129 scopus 로고
    • Suppression of a demand pacemaker by transurethral electrocautery
    • Lerner S.M. Suppression of a demand pacemaker by transurethral electrocautery. Anesth. Analg. 52:1973;703-706.
    • (1973) Anesth. Analg. , vol.52 , pp. 703-706
    • Lerner, S.M.1
  • 8
    • 0023947355 scopus 로고
    • Can transcutaneous electrical nerve stimulation be safely used in patients with permanent pacemakers?
    • Rasmussen M.J., Hayes D.L., Vliestra R.E., Thorsteinsson G. Can transcutaneous electrical nerve stimulation be safely used in patients with permanent pacemakers? Mayo Clin. Proc. 63:1988;443-465.
    • (1988) Mayo Clin. Proc. , vol.63 , pp. 443-465
    • Rasmussen, M.J.1    Hayes, D.L.2    Vliestra, R.E.3    Thorsteinsson, G.4
  • 9
    • 0027281921 scopus 로고
    • Technical and clinical problems in patients with simultaneous implantation of a cardiac pacemaker and spinal cord stimulator
    • Romanó M., Zucco F., Baldini M.R., Allaria B. Technical and clinical problems in patients with simultaneous implantation of a cardiac pacemaker and spinal cord stimulator. PACE. 16:1993;1639-1644.
    • (1993) PACE , vol.16 , pp. 1639-1644
    • Romanó, M.1    Zucco, F.2    Baldini, M.R.3    Allaria, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.