메뉴 건너뛰기




Volumn 39, Issue 1, 1998, Pages 203-207

Mean regional cerebral blood flow images of normal subjects using Technetium-99m-HMPAO by automated image registration

Author keywords

Automated image registration; HMPAO brain SPECT; Image alignment; Regional cerebral blood flow

Indexed keywords

HEXAMETHYLPROPYLENE AMINE OXIME TECHNETIUM TC 99M;

EID: 0031951123     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (26)

References (25)
  • 1
    • 0028943028 scopus 로고
    • Morphology oriented analysis of cerebral SPET using matched magnetic resonance images
    • Stollberger R, Fazekas F, Payer F, Flooh E. Morphology oriented analysis of cerebral SPET using matched magnetic resonance images. Nucl Med Commun 1995;16:265-272.
    • (1995) Nucl Med Commun , vol.16 , pp. 265-272
    • Stollberger, R.1    Fazekas, F.2    Payer, F.3    Flooh, E.4
  • 2
    • 0027270354 scopus 로고
    • Sequential measurements of cerebral blood flow in the acute phase of subarachnoid haemmorrhage
    • Talacchi A. Sequential measurements of cerebral blood flow in the acute phase of subarachnoid haemmorrhage. J Neurosurg Sci 1993;37:9-18.
    • (1993) J Neurosurg Sci , vol.37 , pp. 9-18
    • Talacchi, A.1
  • 4
    • 0028321755 scopus 로고
    • Stereotactic PET atlas of the human brain: Aid for visual interpretation of functional brain images
    • Minoshima S, Kieppe RA, Fery KA, Ishihara M, Kuhl DE. Stereotactic PET atlas of the human brain: aid for visual interpretation of functional brain images. J Nucl Med 1994;35:949-954.
    • (1994) J Nucl Med , vol.35 , pp. 949-954
    • Minoshima, S.1    Kieppe, R.A.2    Fery, K.A.3    Ishihara, M.4    Kuhl, D.E.5
  • 5
    • 0027940111 scopus 로고
    • Anatomic standardization: Linear scaling and nonlinear warping of functional brain images
    • Minoshima S, Kieppe RA, Fery KA, Kuhl DE. Anatomic standardization: linear scaling and nonlinear warping of functional brain images. J Nucl Med 1994;35:1528-1537.
    • (1994) J Nucl Med , vol.35 , pp. 1528-1537
    • Minoshima, S.1    Kieppe, R.A.2    Fery, K.A.3    Kuhl, D.E.4
  • 6
    • 0028053208 scopus 로고
    • A method for assessing the significance of abnormalities in HMPAO brain SPECT images
    • Houston AS, Kemp PM, Macleod MA. A method for assessing the significance of abnormalities in HMPAO brain SPECT images. J Nucl Med 1994;35:239-244.
    • (1994) J Nucl Med , vol.35 , pp. 239-244
    • Houston, A.S.1    Kemp, P.M.2    Macleod, M.A.3
  • 7
    • 0025887185 scopus 로고
    • The influence of positioning and accuracy and precision in emission tomography
    • Links JM. The influence of positioning and accuracy and precision in emission tomography. J Nucl Med 1991;32:1252-1253.
    • (1991) J Nucl Med , vol.32 , pp. 1252-1253
    • Links, J.M.1
  • 8
    • 0029927658 scopus 로고    scopus 로고
    • Registration and alignment of three-dimensional images: An interactive visual approach
    • Habboush IH, Mitchell KD, Mulern RV, Barnes PD, Treves ST. Registration and alignment of three-dimensional images: an interactive visual approach. Radiology 1996;199:573-578.
    • (1996) Radiology , vol.199 , pp. 573-578
    • Habboush, I.H.1    Mitchell, K.D.2    Mulern, R.V.3    Barnes, P.D.4    Treves, S.T.5
  • 9
    • 0023684146 scopus 로고
    • Anatomical functional correlation using an adjustable MRI based ROI atlas with positron emission tomography
    • Evans A, Beil C, Marret C, Thompson C, Hakim A. Anatomical functional correlation using an adjustable MRI based ROI atlas with positron emission tomography. J Cereb Blood Flow Metab 1988;8:513-530.
    • (1988) J Cereb Blood Flow Metab , vol.8 , pp. 513-530
    • Evans, A.1    Beil, C.2    Marret, C.3    Thompson, C.4    Hakim, A.5
  • 10
    • 0344072296 scopus 로고
    • The principal axis transformation: A method for image registration
    • Alpert N, Bradshaw J, Senda M, Correia J. The principal axis transformation: a method for image registration. J Nucl Med 1989;30:776.
    • (1989) J Nucl Med , vol.30 , pp. 776
    • Alpert, N.1    Bradshaw, J.2    Senda, M.3    Correia, J.4
  • 11
    • 0025376174 scopus 로고
    • Correlation methods for centering, rotating, and alignment of functional brain images
    • Junck L, Moen JG, Hutchins GD, Brown MB, Kuhl DE. Correlation methods for centering, rotating, and alignment of functional brain images. J Nucl Med 1990;31: 1220-1226.
    • (1990) J Nucl Med , vol.31 , pp. 1220-1226
    • Junck, L.1    Moen, J.G.2    Hutchins, G.D.3    Brown, M.B.4    Kuhl, D.E.5
  • 12
    • 0026776405 scopus 로고
    • Rapid automated algorithm for aligning and reslicing PET images
    • Woods RP, Cherry SR, Mazziotta JC. Rapid automated algorithm for aligning and reslicing PET images. J Comput Assist Tomogr 1992;16:620-633.
    • (1992) J Comput Assist Tomogr , vol.16 , pp. 620-633
    • Woods, R.P.1    Cherry, S.R.2    Mazziotta, J.C.3
  • 14
    • 0031000099 scopus 로고    scopus 로고
    • SPECT images with technetium-99m-HMPAO and technetium-99m-ECD in normal subjects
    • Koyama M, Kawashima R, Ito H, et al. SPECT images with technetium-99m-HMPAO and technetium-99m-ECD in normal subjects. J Nucl Med 1997;38:587-592.
    • (1997) J Nucl Med , vol.38 , pp. 587-592
    • Koyama, M.1    Kawashima, R.2    Ito, H.3
  • 15
    • 0025339954 scopus 로고
    • A new apparatus for brain imaging: Four head rotating gamma single photon emission computed tomography
    • Kimura K, Hashikawa K, Wtani H, et al. A new apparatus for brain imaging: four head rotating gamma single photon emission computed tomography. J Nucl Med 1990;31: 603-609.
    • (1990) J Nucl Med , vol.31 , pp. 603-609
    • Kimura, K.1    Hashikawa, K.2    Wtani, H.3
  • 16
    • 0344072294 scopus 로고
    • Normal cerebral perfusion of Tc-99m HMPAO brain SPECT: Evaluation by an anatomical standardization technique
    • Koyama M, Kawashima R, Ito H, et al. Normal cerebral perfusion of Tc-99m HMPAO brain SPECT: evaluation by an anatomical standardization technique. Jpn J Nucl Med 1995;32:967-977.
    • (1995) Jpn J Nucl Med , vol.32 , pp. 967-977
    • Koyama, M.1    Kawashima, R.2    Ito, H.3
  • 17
    • 0023638979 scopus 로고
    • Initial experience with technetium-99m-HMPAO brain SPECT
    • Poderka I, Suess E, Goldenberg G, et al. Initial experience with technetium-99m-HMPAO brain SPECT. J Nucl Med 1987;28:1657-1666.
    • (1987) J Nucl Med , vol.28 , pp. 1657-1666
    • Poderka, I.1    Suess, E.2    Goldenberg, G.3
  • 18
    • 0029978042 scopus 로고    scopus 로고
    • Hypoperfusion in the limbic system and prefrontal cortex in depression: SPECT with anatomic standardization technique
    • Ito H, Kawashima R, Awata S, et al. Hypoperfusion in the limbic system and prefrontal cortex in depression: SPECT with anatomic standardization technique. J Nucl Med 1996;37:410-414.
    • (1996) J Nucl Med , vol.37 , pp. 410-414
    • Ito, H.1    Kawashima, R.2    Awata, S.3
  • 19
    • 0027130953 scopus 로고
    • Human brain atlas: High resolution functional and anatomical mapping
    • Roland PE, Graufelds CJ, Wahlin J, et al. Human brain atlas: high resolution functional and anatomical mapping. Hum Brain Mapping 1994;1:173-184.
    • (1994) Hum Brain Mapping , vol.1 , pp. 173-184
    • Roland, P.E.1    Graufelds, C.J.2    Wahlin, J.3
  • 20
    • 0029782184 scopus 로고    scopus 로고
    • Proportional anatomical stereotactic atlas for visual interpretation of brain SPECT perfusion images
    • Verra P, Farman-Ara B, Stievenart JL, et-al. Proportional anatomical stereotactic atlas for visual interpretation of brain SPECT perfusion images. Eur J Nucl Med 1996;23: 871-877.
    • (1996) Eur J Nucl Med , vol.23 , pp. 871-877
    • Verra, P.1    Farman-Ara, B.2    Stievenart, J.L.3
  • 21
    • 0024230549 scopus 로고
    • The use of technetium-99m HMPAO in he assessment of patients with dementia and other neuropsychiatric conditions
    • Smith FW, Besson JAO, Gemmell HG, Sharp PF. The use of technetium-99m HMPAO in he assessment of patients with dementia and other neuropsychiatric conditions. J Cereb Blood Flow Metab 1988;8(suppl):S116-S122.
    • (1988) J Cereb Blood Flow Metab , vol.8 , Issue.SUPPL.
    • Smith, F.W.1    Besson, J.A.O.2    Gemmell, H.G.3    Sharp, P.F.4
  • 23
    • 0023722018 scopus 로고
    • Enhanced detection of focal brain responses using intersubject averaging and change distribution analysis of subtracted PET images
    • Fox PT, Mintun MA, Reiman ER, Raichle ME. Enhanced detection of focal brain responses using intersubject averaging and change distribution analysis of subtracted PET images. J Cereb Blood Flow Metab 1988;8:642-653.
    • (1988) J Cereb Blood Flow Metab , vol.8 , pp. 642-653
    • Fox, P.T.1    Mintun, M.A.2    Reiman, E.R.3    Raichle, M.E.4
  • 24
    • 0027272428 scopus 로고
    • Noninvasive measurements of regional cerebral blood flow using technetium-99m-hexamethylpropylene amine oxime
    • Matsuda H, Tsuji S, Shuke N, Sumiya H, Tonami N, Hisada K. Noninvasive measurements of regional cerebral blood flow using technetium-99m-hexamethylpropylene amine oxime. J Nucl Med 1993;20:391-401.
    • (1993) J Nucl Med , vol.20 , pp. 391-401
    • Matsuda, H.1    Tsuji, S.2    Shuke, N.3    Sumiya, H.4    Tonami, N.5    Hisada, K.6
  • 25
    • 0344934316 scopus 로고    scopus 로고
    • Intersubject transformation of brain SPECT by automated image registration (AIR): Effects of defects in the target image
    • Kinomura S, Kawashima R, Sato K, Kinomura S Imran MB, Fukuda H. Intersubject transformation of brain SPECT by automated image registration (AIR): effects of defects in the target image [Abstract], Ann Nucl Med 1996;10(suppl):s222.
    • (1996) Ann Nucl Med , vol.10 , Issue.SUPPL.
    • Kinomura, S.1    Kawashima, R.2    Sato, K.3    Kinomura, S.4    Imran, M.B.5    Fukuda, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.