Volumn 78, Issue 3, 1998, Pages 201-204

Subbandage pressure measurements comparing a long-stretch with a short- stretch compression bandage

Author keywords

Subcutaneous bloodflow; Vein muscle pump; Venous insufficiency

Indexed keywords

ARTICLE; BANDAGE; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED STUDY; HUMAN; LEG COMPRESSION; LEG ULCER; PRESSURE MEASUREMENT; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; REST; STANDING; SUPINE POSITION; WALKING;

EID: 0031946241     PISSN: 00015555     EISSN: None     Source Type: Journal    
DOI: 10.1080/000155598441530     Document Type: Article
Times cited : (23)

References (12)
  • 2
    • 7144243153 scopus 로고    scopus 로고
    • Coloplast A/S, Humlebæk, Denmark. Personal communication
    • Nielsen JS. Coloplast A/S, Humlebæk, Denmark. Personal communication
    • Nielsen, J.S.1
  • 3
    • 0002812063 scopus 로고
    • Bandages and bandaging: The science behind the art
    • Thomas S. Bandages and bandaging: the science behind the art. Care Sci Practice 1990; 8: 56 60.
    • (1990) Care Sci Practice , vol.8 , pp. 56-60
    • Thomas, S.1
  • 4
    • 0026092525 scopus 로고
    • Nocturnal variations in subcutaneous blood flow rate in lower leg of normal human subjects
    • Sindrup JH, Kastrup J, Jørgensen B, Bülow J, Lassen NA. Nocturnal variations in subcutaneous blood flow rate in lower leg of normal human subjects. Am J Physiol 1991; 260: 480-485.
    • (1991) Am J Physiol , vol.260 , pp. 480-485
    • Sindrup, J.H.1    Kastrup, J.2    Jørgensen, B.3    Bülow, J.4    Lassen, N.A.5
  • 5
    • 0006095633 scopus 로고
    • The 133 Xenon washout technique for quantitative measurement of cutaneous and subcutaneous blood flow rates
    • Serup J, Jemec GBE. Boca Raton: CRC Press
    • Sejrsen P. The 133 Xenon washout technique for quantitative measurement of cutaneous and subcutaneous blood flow rates. In: Serup J, Jemec GBE. Handbook of non-invasive methods and the skin. Boca Raton: CRC Press, 1995: 429-436.
    • (1995) Handbook of Non-invasive Methods and the Skin , pp. 429-436
    • Sejrsen, P.1
  • 8
    • 0027625027 scopus 로고
    • Accuracy of interface pressure measurement systems
    • Allen V, Ryan DW, Lomax N, Murray A. Accuracy of interface pressure measurement systems. J Biomed Eng 1993; 15: 344-348.
    • (1993) J Biomed Eng , vol.15 , pp. 344-348
    • Allen, V.1    Ryan, D.W.2    Lomax, N.3    Murray, A.4
  • 9
    • 0025909176 scopus 로고
    • Effect of time and posture on pressure profiles obtained by three different types of compression
    • Callam MJ, Haiart D, Farouk M, Brown D, Prescott RJ, Ruckley CV. Effect of time and posture on pressure profiles obtained by three different types of compression. Phlebology 1991; 6: 79 84.
    • (1991) Phlebology , vol.6 , pp. 79-84
    • Callam, M.J.1    Haiart, D.2    Farouk, M.3    Brown, D.4    Prescott, R.J.5    Ruckley, C.V.6
  • 10
    • 0029776385 scopus 로고    scopus 로고
    • Interface pressure measurements underneath elastic and non-elastic bandages
    • Veraart JCJM, Neumann HAM. Interface pressure measurements underneath elastic and non-elastic bandages. Phlebology 1996; 11 Suppl 1: 2 5.
    • (1996) Phlebology , vol.11 , Issue.1 SUPPL. , pp. 2-5
    • Veraart, J.C.J.M.1    Neumann, H.A.M.2
  • 11
    • 0023922449 scopus 로고
    • Regulating the pressure under compression bandages for venous leg ulcers
    • Stockh
    • Hansson C, Swanbeck G. Regulating the pressure under compression bandages for venous leg ulcers. Acta Derm Venereol (Stockh) 1988; 68: 245 249.
    • (1988) Acta Derm Venereol , vol.68 , pp. 245-249
    • Hansson, C.1    Swanbeck, G.2
  • 12
    • 0026044881 scopus 로고
    • Diurnal variations in lower leg subcutaneous blood flow rate in patients with chronic venous leg ulcers
    • Sindrup JH, Kastrup J, Kristensen JK. Diurnal variations in lower leg subcutaneous blood flow rate in patients with chronic venous leg ulcers. Br J Dermatol 1991; 125: 436-442.
    • (1991) Br J Dermatol , vol.125 , pp. 436-442
    • Sindrup, J.H.1    Kastrup, J.2    Kristensen, J.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.