메뉴 건너뛰기




Volumn 5, Issue 1, 1998, Pages 41-53

Standardized measurement of visual acuity

Author keywords

Contrast; Forced choice; Iuminance; LogMAR; Optotype charts; Visual acuity

Indexed keywords

DISTANCE PERCEPTION; METHODOLOGY; PRACTICE GUIDELINE; PRIORITY JOURNAL; REVIEW; STANDARDIZATION; VISION TEST; VISUAL ACUITY;

EID: 0031942093     PISSN: 09286586     EISSN: None     Source Type: Journal    
DOI: 10.1076/opep.5.1.41.1499     Document Type: Review
Times cited : (77)

References (46)
  • 1
    • 0019260848 scopus 로고
    • Recommended standard procedures for the clinical measurement and specification of visual acuity. Report of working group 39
    • National Academy of Science National Research Council (NAS-NRC). Recommended standard procedures for the clinical measurement and specification of visual acuity. Report of working group 39. Adv Ophthalmol 1980;41 103-48.
    • (1980) Adv Ophthalmol , vol.41 , pp. 103-148
  • 2
    • 0030026335 scopus 로고    scopus 로고
    • Standardizing the measurement of visual acuity for clinical and research studies
    • Ferris FL III, Bailey I. Standardizing the measurement of visual acuity for clinical and research studies. Ophthalmology 1996;103:181-2.
    • (1996) Ophthalmology , vol.103 , pp. 181-182
    • Ferris III, F.L.1    Bailey, I.2
  • 3
    • 0002399365 scopus 로고
    • Comparison of three types of test target for the measurement of visual acuity
    • Sloan LL, Rowland WM, Altman A. Comparison of three types of test target for the measurement of visual acuity. Q Rev Ophthalmol 1952;8:4-16.
    • (1952) Q Rev Ophthalmol , vol.8 , pp. 4-16
    • Sloan, L.L.1    Rowland, W.M.2    Altman, A.3
  • 4
    • 0000597505 scopus 로고
    • New test chart for the measurement of visual acuity at far and near distance
    • Sloan LL. New test chart for the measurement of visual acuity at far and near distance. Am J Ophthalmol 1959;48:807-13.
    • (1959) Am J Ophthalmol , vol.48 , pp. 807-813
    • Sloan, L.L.1
  • 6
    • 0019028416 scopus 로고
    • The design and use of a new near chart
    • Bailey I, Lovie JF. The design and use of a new near chart. Am J Optom Physiol Opt 1980;57:378-87.
    • (1980) Am J Optom Physiol Opt , vol.57 , pp. 378-387
    • Bailey, I.1    Lovie, J.F.2
  • 8
    • 0021913039 scopus 로고
    • A distance visual acuity chart incorporating some new design features
    • Strong G, Woo GC. A distance visual acuity chart incorporating some new design features. Arch Ophthalmol 1985;103:44.
    • (1985) Arch Ophthalmol , vol.103 , pp. 44
    • Strong, G.1    Woo, G.C.2
  • 9
    • 0018404728 scopus 로고
    • Scaling of visual acuity measurements
    • Westheimer G. Scaling of visual acuity measurements. Arch ophthalmol 1979;97:327-30.
    • (1979) Arch Ophthalmol , vol.97 , pp. 327-330
    • Westheimer, G.1
  • 10
    • 0019162685 scopus 로고
    • How good is normal visual acuity? A study of letter acuity thresholds as a function of age
    • Frisén L, Frisén M. How good is normal visual acuity? A study of letter acuity thresholds as a function of age. Graefes Arch Klin Exp Ophthalmol 1981;215(3): 149-57.
    • (1981) Graefes Arch Klin Exp Ophthalmol , vol.215 , Issue.3 , pp. 149-157
    • Frisén, L.1    Frisén, M.2
  • 12
    • 0000956970 scopus 로고
    • A study of separation difficulty: Its relationship to visual acuity in normal and amblyopic eyes
    • Stuart JM, Burian HM. A study of separation difficulty: its relationship to visual acuity in normal and amblyopic eyes. Am J Ophthalmol 1962;53:471-7.
    • (1962) Am J Ophthalmol , vol.53 , pp. 471-477
    • Stuart, J.M.1    Burian, H.M.2
  • 15
    • 0001662570 scopus 로고
    • Measurement of visual acuity: A critical review
    • Sloan LL. Measurement of visual acuity: a critical review. Arch Ophthalmol 1951;45:704.
    • (1951) Arch Ophthalmol , vol.45 , pp. 704
    • Sloan, L.L.1
  • 17
    • 0006543057 scopus 로고
    • New York: Crowell
    • Colorimetry Comittee of The Optical Society of America. The science of color. New York: Crowell, 1953:297.
    • (1953) The Science of Color , pp. 297
  • 18
    • 15144355934 scopus 로고
    • Sources suitable for use in illuminating visual acuity charts
    • Cool and Smith. New York: Springer
    • Fry GA. Sources suitable for use in illuminating visual acuity charts. In: Cool and Smith. Frontiers of Visual Science. New York: Springer, 1977.
    • (1977) Frontiers of Visual Science
    • Fry, G.A.1
  • 19
    • 0024788808 scopus 로고
    • Contrast sensitivity for letters and gratings targets under various stimulus conditions
    • Herse PR, Bedell HE. Contrast sensitivity for letters and gratings targets under various stimulus conditions. Optom Vis Sci 1989;66:774-81.
    • (1989) Optom Vis Sci , vol.66 , pp. 774-781
    • Herse, P.R.1    Bedell, H.E.2
  • 20
    • 0001161808 scopus 로고
    • Effect of reduced contrast on visual acuity as measured with Snellen test letters
    • Ludvig E. Effect of reduced contrast on visual acuity as measured with Snellen test letters. Arch Ophthalmol 1941;25:469-74.
    • (1941) Arch Ophthalmol , vol.25 , pp. 469-474
    • Ludvig, E.1
  • 21
    • 0017566337 scopus 로고
    • Effects of luminance and contrast on visual acuity, ages 16-90 years
    • Richards OW. Effects of luminance and contrast on visual acuity, ages 16-90 years. Am J Optom Physiol Opt 1977;54:178-84.
    • (1977) Am J Optom Physiol Opt , vol.54 , pp. 178-184
    • Richards, O.W.1
  • 22
    • 0015849555 scopus 로고
    • From 20/20 to 6/6 or to 4/4?
    • Hofstetter HW. From 20/20 to 6/6 or to 4/4? Am J Optom 1973;50:212-22.
    • (1973) Am J Optom , vol.50 , pp. 212-222
    • Hofstetter, H.W.1
  • 23
    • 0017846154 scopus 로고
    • Considerations related to 'going metric', the best metric distance for measuring visual acuity and the correct use of Snellen fraction
    • Sloan LL, Enoch JM. Considerations related to 'going metric', the best metric distance for measuring visual acuity and the correct use of Snellen fraction. Arch Ophthalmol 1978;96:1567.
    • (1978) Arch Ophthalmol , vol.96 , pp. 1567
    • Sloan, L.L.1    Enoch, J.M.2
  • 24
    • 15144341371 scopus 로고
    • Ophthalmic test types
    • Bennett AG. Ophthalmic test types. Br J Physiol Opt 1965;22:236-71.
    • (1965) Br J Physiol Opt , vol.22 , pp. 236-271
    • Bennett, A.G.1
  • 25
    • 0038827637 scopus 로고
    • San Francisco: International Council of Ophthalmology
    • Visual function committee. Concilium Ophthalmologicum Universale. Visual acuity measurement standard. San Francisco: International Council of Ophthalmology, 1984.
    • (1984) Visual Acuity Measurement Standard
  • 26
    • 0017052413 scopus 로고
    • New design principles for visual acuity letter charts
    • Bailey IE, Lovie JF. New design principles for visual acuity letter charts. Am J Optom Physiol Opt 1976;53:740-5.
    • (1976) Am J Optom Physiol Opt , vol.53 , pp. 740-745
    • Bailey, I.E.1    Lovie, J.F.2
  • 27
    • 15144343137 scopus 로고
    • Appendice IV «Formule e procedure di calcolo»
    • Torino: Minerva Med
    • Paliaga GP. Appendice IV «Formule e procedure di calcolo». In: L'Esame del Visus. Torino: Minerva Med, 1991:149-50.
    • (1991) L'Esame del Visus , pp. 149-150
    • Paliaga, G.P.1
  • 29
    • 84990619118 scopus 로고
    • Task complexity and visual acuity in senile macular degeneration
    • Kitchin JE, Bailey I. Task complexity and visual acuity in senile macular degeneration. Aust J Ophthalmol 1981;64:235.
    • (1981) Aust J Ophthalmol , vol.64 , pp. 235
    • Kitchin, J.E.1    Bailey, I.2
  • 30
    • 0021999999 scopus 로고
    • Psychophysics of reading. II. Low vision
    • Legge GE, Rubin GS, Pelli DG, et al. Psychophysics of reading. II. Low vision. Vision Res 1985;25:253.
    • (1985) Vision Res , vol.25 , pp. 253
    • Legge, G.E.1    Rubin, G.S.2    Pelli, D.G.3
  • 31
    • 0019422216 scopus 로고
    • Reading performance in low vision patients: Relation to contrast and contrast sensitivity
    • Brown B. Reading performance in low vision patients: relation to contrast and contrast sensitivity. Am J Optom Physiol Opt 1981;58:218.
    • (1981) Am J Optom Physiol Opt , vol.58 , pp. 218
    • Brown, B.1
  • 32
    • 0017062004 scopus 로고
    • Techniques, instruments, cases. the measurement and recording of vision at near test distances
    • Meher EB, Freid AN. Techniques, instruments, cases. The measurement and recording of vision at near test distances. Am J Optom Physiol Opt 1976;53:314.
    • (1976) Am J Optom Physiol Opt , vol.53 , pp. 314
    • Meher, E.B.1    Freid, A.N.2
  • 33
    • 0017588920 scopus 로고
    • Type-size variability for near point acuity test
    • Jose RT, Atcherson RM. Type-size variability for near point acuity test. Am J Optom Physiol Opt 1977;54:634.
    • (1977) Am J Optom Physiol Opt , vol.54 , pp. 634
    • Jose, R.T.1    Atcherson, R.M.2
  • 35
    • 0013828015 scopus 로고
    • Ophthalmic test types
    • Bennet AG. Ophthalmic test types. Br J Physiol Opt 1965;22:238.
    • (1965) Br J Physiol Opt , vol.22 , pp. 238
    • Bennet, A.G.1
  • 36
    • 15144346710 scopus 로고
    • Metodi di misura dell'acutezza visiva
    • Chapt 3. Torino: Minerva Med.
    • Paliaga GP. Chapt 3. Metodi di misura dell'acutezza visiva. In: L'Esame del Visus. Torino: Minerva Med. 1991:25-8.
    • (1991) L'Esame del Visus , pp. 25-28
    • Paliaga, G.P.1
  • 37
    • 0000415196 scopus 로고
    • The percentage evolution of macular vision
    • Snell A, Sterling S. The percentage evolution of macular vision. Arch Ophthalmol 1925;54:443.
    • (1925) Arch Ophthalmol , vol.54 , pp. 443
    • Snell, A.1    Sterling, S.2
  • 38
    • 0038489611 scopus 로고
    • On the problem of an international nomenclature for designating visual acuity
    • Ogle KN. On the problem of an international nomenclature for designating visual acuity. Am J Ophthalmol 1953;36:909.
    • (1953) Am J Ophthalmol , vol.36 , pp. 909
    • Ogle, K.N.1
  • 39
    • 0024205429 scopus 로고
    • The use of accurate visual acuity measurements in clinical anti-cataract formulation trials
    • Elliot DB, Sheridan M. The use of accurate visual acuity measurements in clinical anti-cataract formulation trials. Ophthalm Physiol Opt 1988;8:397-401.
    • (1988) Ophthalm Physiol Opt , vol.8 , pp. 397-401
    • Elliot, D.B.1    Sheridan, M.2
  • 40
    • 0000430669 scopus 로고
    • Reading card for selection of optical aids for the partially sighted
    • Sloan LL, Brown DJ. Reading card for selection of optical aids for the partially sighted. Am J Ophthalmol 1963;55:1187.
    • (1963) Am J Ophthalmol , vol.55 , pp. 1187
    • Sloan, L.L.1    Brown, D.J.2
  • 41
    • 15144349722 scopus 로고
    • Some general aspects of vision
    • New York: Pergamon Press
    • Davson H. Some general aspects of vision. In: Physiology of the eye, 5th Edition. New York: Pergamon Press, 1990:225-6.
    • (1990) Physiology of the Eye, 5th Edition , pp. 225-226
    • Davson, H.1
  • 43
    • 0024360774 scopus 로고
    • Automatisierte Messung des Fernvisus in Anlehnung an die Din Strategie
    • Effert R, Steinmetz H, Jansen W, et al. Automatisierte Messung des Fernvisus in Anlehnung an die DIN Strategie. Klin Mbl Augenheilk 1989;195:39-43.
    • (1989) Klin Mbl Augenheilk , vol.195 , pp. 39-43
    • Effert, R.1    Steinmetz, H.2    Jansen, W.3
  • 44
    • 15144349389 scopus 로고
    • Sehschärfebestimmung
    • Hartmann E, Sehschärfebestimmung. Klin Mbl Augenheilk 1984;189:147-56.
    • (1984) Klin Mbl Augenheilk , vol.189 , pp. 147-156
    • Hartmann, E.1
  • 45
    • 0019020390 scopus 로고
    • The Framingham Eye Study
    • Leibowitz HM, et al. The Framingham Eye Study. Surv Ophthalmol (Suppl) 1980:335-610.
    • (1980) Surv Ophthalmol , Issue.SUPPL. , pp. 335-610
    • Leibowitz, H.M.1
  • 46
    • 0024357409 scopus 로고
    • Chart for visual acuity screening
    • Wong D, Kaye SB. Chart for visual acuity screening. Br J Ophthalmol 1989;73:457-60.
    • (1989) Br J Ophthalmol , vol.73 , pp. 457-460
    • Wong, D.1    Kaye, S.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.